Abstract
This chapter presents results of technical calculations involving the selection heating structures of heat recovery steam generators and of power of gas turbine for modernization of coal-fired power unit to dual-fuel steam-gas system. Calculations were conducted for the condensing mode and for operation of the unit in cogeneration. Differences between the optimal thermodynamic capacity of the gas turbine for the condensing mode and cogeneration are presented with regard to a 370 MW power unit and relative to the number of degrees of pressure in the heat recovery steam generator.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bartnik R (2009) Combined cycle power plants. Thermal and economic effectiveness. WNT, Warszawa
Bartnik R, Buryn Z (2011) Conversion of coal-fired power plants to cogeneration and combined-cycle. Thermal and economic effectiveness. Springer, London