Load demands in power generation for the national or district grid often require turbo-generator sets to operate under adverse operational requirements with respect to maintenance and design ideals. Such instances typically involve turbines operating beyond maintenance schedules or at part load conditions. Part load operations for hydro turbines, in particular, present a set of unique problems. Power generation managers have to manage the risks of machine damage imposed on their engineering assets in attempt to ensure continuing and stable electricity despatch. This paper presents two case studies examining the risks of machine failures from adverse operating requirements and how it could be managed by condition monitoring. One involves gas turbines operating beyond OEM recommended operating hours between maintenance. Blades failures are potential concerns as well. The risks were evaluated and managed with vibration monitoring of the blades passing frequencies. The other case study relates to hydro turbines operating in rough zones at part load conditions dictated by load stabilization requirements of the electricity grid. Measurements of vibrations, draft tube pressures and strain gauging showed distressed conditions when the turbines were operated at part loads. Premature failures were experienced in these units.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Meher-Homji CB (1995) Blading vibration and failures in gas turbines: Part C – Detection and troubleshooting. ASME no. 95-GT-420
Meher-Homji (1995) CB Blading vibration and failures in gas turbines: Part D – Case studies. ASME no. 95-GT-421
Allianz Center for Technology (2008) Product service information 1/00. Information / Damage analysis. www.en.allianz-azt.com
Mitchell J (1975) Examination of pump cavitation, gear mesh and blade performance using external vibration characteristics. In: Pr 4th Turbomach Sym Texas A&M University 39–45
Kubiak J, Gonzalez G, Garcia G, Urquiza B (2001) Hybrid fault pattern for the diagnosis of gas turbine component degradation. Int Joint Power Generation Conf New Orleans no. PWR-19112
Leong MS, Lim MH (2008) Detection of blade rubs and looseness in gas turbines – Operational field experience and laboratory study. 5th Int Conf Cond Monit Mach Failure Detect Prev Tech Edinburgh 901–912
Lim MH, Leong MS (2008) Improved blade fault diagnosis using discrete blade passing energy packet and rotor dynamics wavelet analysis. ASME no. GT2010-22218, ASME Turbo Expo2010: Power for Land, Sea and Air, Glasgow
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag London Limited
About this chapter
Cite this chapter
Leong, M.S., Hee, N.B. (2012). Managing the Risks of Adverse Operational Requirements in Power Generation – Case Study in Gas and Hydro Turbines. In: Amadi-Echendu, J., Willett, R., Brown, K., Mathew, J. (eds) Asset Condition, Information Systems and Decision Models. Engineering Asset Management Review. Springer, London. https://doi.org/10.1007/978-1-4471-2924-0_11
Download citation
DOI: https://doi.org/10.1007/978-1-4471-2924-0_11
Publisher Name: Springer, London
Print ISBN: 978-1-4471-2923-3
Online ISBN: 978-1-4471-2924-0
eBook Packages: EngineeringEngineering (R0)