Skip to main content

Abstract

This paper reports on indirect soil suction measurement methods. Indirect suction measurement techniques measure the moisture equilibrium condition of the soil instead of suction. The moisture equilibrium condition of the soil can be determined by primary means as in vapor pressure, secondary means as through another porous medium or tertiary means as in measuring other physical properties of the porous medium that indicates its moisture equilibrium condition. Indirect suction measurement techniques employing primary means include thermocouple psychrometers, transistor psychrometer and chilled-mirror psychrometer. Indirect suction measurement techniques employing secondary means includes the filter paper method and indirect suction measurement techniques employing tertiary means include thermal conductivity sensors and electrical conductivity sensors. These techniques have been widely used in engineering practice and in research laboratories. However, each of these techniques has its own limitations and capabilities, and active research into improving these techniques is ongoing in universities, research laboratories, and private sector. This paper outlines working principles, calibration, measurement, and application areas of these methods based on recent literature and practice.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Aitchison GD, Richards BG (1965) A broad-scale study of moisture conditions in pavement subgrades throughout Australia. In: Moisture in soils beneath covered areas. Butterworths, Australia, pp 198–204

    Google Scholar 

  • Albrecht BA, Benson CH, Beuermann S (2003) Polymer capacitance sensors for measuring soil gas humidity in drier soils. Geotech Test J 26(1):1–9

    Google Scholar 

  • ASTM D5298-94 (1994) Standard test method for measurement of soil potential (suction) using filter paper. In: 1994 Annual book of ASTM standards. ASTM, Philadelphia

    Google Scholar 

  • ASTM D6836-02 (2003) Standard test methods for determination of the soil water characteristic curve for desorption using a hanging column, pressure extractor, chilled mirror hygrometer, and/or centrifuge. In: 2003 Annual book of ASTM standards. ASTM, Philadelphia

    Google Scholar 

  • Blatz JA, Graham J (2003) Elastic-plastic modelling of unsaturated soil using results from a new triaxial test with controlled suction. Geotechnique 53(1):113–122

    Article  Google Scholar 

  • Bulut R, Wray WK (2005) Free energy of water—suction—in filter papers. Geotech Test J 28(4):355–364

    Article  Google Scholar 

  • Bulut R, Aubeny CP, Lytton RL (2005) Unsaturated soil diffusivity measurements. In: International symposium on advanced experimental unsaturated soil mechanics, Trento, Italy, 27–29 June

    Google Scholar 

  • Bulut R, Lytton RL, Wray WK (2001) Soil suction measurements by filter paper. In: Vipulanandan C, Addison MB, Hasen M (eds) Expansive clay soils and vegetative influence on shallow foundations, ASCE geotechnical special publication no. 115. Houston, Texas, pp 243–261

    Google Scholar 

  • Bulut R, Hineidi SM, Bailey B (2002) Suction measurements—filter paper and chilled mirror psychrometer. In: Proceedings of the Texas Section American Society of Civil Engineers, Fall Meeting, Waco, 2–5 October

    Google Scholar 

  • Bulut R, Park S-W, Lytton RL (2000) Comparison of total suction values from psychrometer and filter paper methods. In: Unsaturated soils for Asia. Proceedings of the Asian conference on unsaturated soils, UNSAT-ASIA 2000, Singapore, 18–19 May, pp 269–273

    Google Scholar 

  • Bouyoucos GJ, Mick AH (1940) Comparison of absorbent materials employed in the electrical resistance method of making a continuous measurement of soil moisture under field conditions. Proc Soil Sci Soc Am 5:77–79

    Article  Google Scholar 

  • Feng M, Fredlund DG (2003) Calibration of thermal conductivity sensors with consideration of hysteresis. Can Geotech J 40(5):1048–1055

    Article  Google Scholar 

  • Fredlund DG, Rahardjo H (1993) Soil mechanics for unsaturated soils. John Wiley & Sons, Inc, New York

    Google Scholar 

  • Fredlund DG, Wong DKH (1989) Calibration of thermal conductivity sensors for measuring soil suction. Geotech Test J 12(3):188–194

    Google Scholar 

  • Hamblin AP (1981) Filter paper method for routine measurement of field water potential. J Hydrol 53:355–360

    Article  Google Scholar 

  • He L-C (1999) Evaluation of instruments for measurement of suction in unsaturated soils. MEng Thesis, School of Civil & Structural Engineering, Nanyang Technological University, Singapore

    Google Scholar 

  • Houston SL, Houston WR, Wagner AM (1994) Laboratory filter paper measurements. Geotech Test J 17(2):185–194

    Article  Google Scholar 

  • Leong E-C, He L, Rahardjo H (2002) Factors affecting the filter paper method for total and matric suction measurements. Geotech Test J 25(3):322–333

    Google Scholar 

  • Leong E-C, Tripathy S, Rahardjo H (2003) Total suction measurement of unsaturated soils with a device using the chilled-mirror dew-point technique. Geotechnique 53(2):173–182

    Article  Google Scholar 

  • Marjerison B, Richardson N, Widger A, Fredlund DG, Berthelot C (2001) Installation of sensors and measurement of soil suction below thin membrane of surface pavements in Sasketchewan. In: Proceedings of 54th Canadian geotechnical conference, Calgary, Alta, 16–19 September, pp 1328–1334

    Google Scholar 

  • Nichol C, Smith L, Beckie R (2003) Long term measurement of matric suction using thermal conductivity sensors. Can Geotech J 40(3):587–597

    Article  Google Scholar 

  • O’Kane M, Wilson GW, Barbour SL (1998) Instrumentation and monitoring of an engineered soil cover system for mine waste rock. Can Geotech J 35:828–846

    Article  Google Scholar 

  • Oloo SY, Fredlund DG (1995) Matric suction measuring in an expansive soil subgrade in Kenya. In: Unsaturated soils: proceedings of 1st international conference on unsaturated soils, Paris

    Google Scholar 

  • Phene CJ, Hoffman GJ, Rawlins SL (1971) Measuring soil matric potential in-situ by sensing heat dissipation within a porous body: I. Theory and sensor construction. Proc Soil Sci Soc Am 35:27–33

    Google Scholar 

  • Reece CF (1996) Evaluation of a line heat dissipation sensor for measuring soil matric potential. Soil Sci Soc Am J 60(4):1022–1028

    Google Scholar 

  • Richards LA, Ogata G (1958) A thermocouple for vapor pressure measurement in biological and soil systems at high humidity. Science 128:1089–1090

    Article  Google Scholar 

  • Ridley AM (1993) The measurement of soil matric suction. PhD thesis, Imperial College of Science, Technology and Medicine, University of London

    Google Scholar 

  • Siemens GA, Blatz JA (2005) Soil suction measurement using the Xeritron Sensor in two different types of infiltration tests on a swelling soil. In: International symposium on advanced experimental unsaturated soil mechanics, Trento, 27–29 June

    Google Scholar 

  • Skinner A, Hignett C, Dearden J (1997) Resurrecting the gypsum block for soil moisture measurement. In: Australian viticulture, October/November 1997

    Google Scholar 

  • Spanner DC (1951) The Peltier effect and its use in the measurement of suction pressure. J Exp Bot 2:145–168

    Article  Google Scholar 

  • UST 2004. http://www.soilvision.com/subdomains/unsaturatedsoil.com/sensor.shtml

    Google Scholar 

  • Walker SC, Gallipoli D, Toll DG (2005) The effect of structure on the water retension of soil tested using different methods of suction measurement. In: International symposium on advanced experimental unsaturated soil mechanics, Trento, 27–29 June

    Google Scholar 

  • Woodburn JA, Holden JC, Peter P (1993) The transistor psychrometer: a new instrument for measuring soil suction. In: Houston SL, Wray WK (eds) Unsaturated soils. ASCE geotechnical special publication no. 39. Dallas, Texas, pp 91–102

    Google Scholar 

  • Zhang X, Leong EC, Rahardjo H (2001) Evaluation of a thermal conductivity sensor for measurement of matric suction in residual soil slopes. In: Proceedings of 14th southeast Asian geotechnical conference, Hong Kong, pp 611–616

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Rifat Bulut .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer Science+Business Media B.V.

About this chapter

Cite this chapter

Bulut, R., Leong, E.C. (2008). Indirect Measurement of Suction. In: Tarantino, A., Romero, E., Cui, YJ. (eds) Laboratory and Field Testing of Unsaturated Soils. Springer, Dordrecht. https://doi.org/10.1007/978-1-4020-8819-3_3

Download citation

Publish with us

Policies and ethics