Abstract
The question of how much force was required to create a particular injury is one that pathologists are often required to answer as part of the investigation of any serious injury that may or may not result in death. Many implements are used in causing either sharp or blunt force trauma, and this chapter reviews some of the important features in determining how much force was required to create a stabbing or slashing injury with a sharp weapon and gives some additional insights into forces required for biting and creating blunt force trauma with either bottles or other weapons. It is important to consider the weapon type and geometry and also the actions of both the victim and the assailant to give as full a picture as possible as to how different injuries arise. Additionally, the structure and mechanical properties of skin are an important factor in determining the amount of force required for penetration.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
J. Kielhorn, S. Melching- Kollmuß, I. Mangelsdorf, Dermal Absorption. World Health Organisation, WHO Press 2006, Geneva, Switzerland.
Rosai J. Rosai & Ackerman’s surgical pathology. 9th ed. Edinburgh, London, New York: Mosby; 2004. p. 94–6.
Tregear RT. Physical functions of the skin. London, New York: Academic; 1966.
Hult AM, Goltz RW. The measurement of elastin in human skin and its quantity in relation to age. J Invest Dermatol. 1965;44:408–12.
Dombi GW, Haut RC. The tensile strength of skin and correlations with collagen content. Advances in bioengineering. ASME. 1985;32:95–6.
Daly CH. Biomechanical properties of dermis. J Invest Dermatol. 1982;79 Suppl 1:17s–20.
Agache PG, Monneur C, Leveque JL, De Rigal J. Mechanical properties and young’s modulus of human skin in vivo. Arch Dermatol Res. 1980;269(3):221–32.
Edwards C, Marks R. Evaluation of biomechanical properties of human skin. Clin Dermatol. 1995;13(4):375–80.
Bader DL, Bowker P. Mechanical characteristics of skin and underlying tissues in vivo. Biomaterials. 1983;4(4):305–8.
Wilkes GL, Brown IA, Wildnauer RH. The biomechanical properties of skin. CRC Crit Rev Bioeng. 1973;1(4):453–95.
Cox HT. The cleavage lines of the skin. Br J Surg. 1941;29:234–40.
Shergold OA, Fleck NA. Mechanisms of deep penetration of soft solids, with application to the injection and wounding of skin. Proc R Soc Lond A. 2004;460:3037–58.
Shergold OA, Fleck NA. Experimental investigation into the deep penetration of soft solids by sharp and blunt punches, with application to the piercing of skin. J Bioeng. 2005;127:838–48.
Davison AM. The incised wound in essentials of autopsy practice. In: Rutty GN, editor. Recent advances, topics and developments. London: Springer; 2003. p. 187–220.
Hainsworth SV, Delaney RJ, Rutty GN. How sharp is sharp? Methods for quantifying the sharpness and penetrability of kitchen knives used in stabbings. Int J Legal Med. 2008;122:281–91.
O’Callaghan PT. The biomechanics of stab wounds. Ph.D. thesis, Cardiff University, Cardiff; 1999.
O’Callaghan PT, Jones MD, James DS, Leadbetter S, Holt CA, Nokes LD. Dynamics of stab wounds: force required for penetration of various cadaveric human tissues. Forensic Sci Int. 1999;104:173–8.
Knight B. The dynamics of stab wounds. Forensic Sci. 1975;6:249–55.
Nolan G, Hainsworth SV, Rutty GN. Forces required for a knife to penetrate a variety of clothing types. J Forensic Sci. 2013 (in press).
Bleetman A, Watson CH, Horsfall I, Champion SM. Wounding patterns and human performance in knife attacks: optimising the protection provided by knife-resistant body armour. J Clin Forensic Med. 2003;10:243–8.
Watson CH, Horsfall I, Champion SM, Harrod IC. Blade sharpness and its effect on the testing of body armour. In: Proceedings of the personal armour systems symposium 2002, The Hague, 2002
Faller-Marquardt M, Pollak S. Homicide with a screwdriver and simulation of a similar offence by self-infliction of injuries. J Clin Forensic Med. 1996;3:141–7.
Schulz F, Colmant HJ, Trubner K. Penetrating spinal injury inflicted by screwdriver: unusual morphological findings. J Clin Forensic Med. 1995;2:153–5.
Croft AM, Ferllini R. Macroscopic characteristics of screwdriver trauma. J Forensic Sci. 2007;52:1243–51.
Parmar K, Hainsworth SV, Rutty GN. Quantification of forces required for stabbing with screwdrivers and other blunter instruments. Int J Legal Med. 2012;126:43–53.
Saukko P, Knight B. The pathology of wounds: the incised wound. In: Saukko P, Knight B, editors. Knight’s forensic pathology. 3rd ed. London: Arnold; 2004. p. 155–66.
Madea B, Schmidt PT, Lignitz E, Padosch SA. Skull injuries caused by blows with glass bottles. In: Tsokos M, editor. Forensic pathology reviews, vol. 2. Totowa: Humana Press Inc.; 2005. p. 27–41.
Weibull WA. Statistical distribution function of wide applicability. J Appl Mech. 1951;18:293–7.
Lawn BR. Fracture of brittle solids. 2nd ed. Cambridge: Cambridge University Press; 1993.
Nolan G, Lawes SDA, Hainsworth SV, Rutty GN. An investigation into the force required for broken glass bottles to penetrate a skin simulant. Int J Legal Med. 2012;126:19–25.
O’Callaghan PT, Jones MD, James DS, Leadbetter S, Evans SL, Nokes LDM. A biomechanic reconstruction of a wound caused by a glass shard – a case report. Forensic Sci Int. 1999;117:221–31.
Bolliger SA, Ross S, Oesterhelweg L, Thali MJ, Kneubuehl BP. Are full or empty beer bottles sturdier and does their fracture-threshold suffice to break the human skull? J Forensic Leg Med. 2009;16:138–42.
Preston FW. Bottle breakage—causes and types of fractures. Am Ceram Soc Bull. 1939;18:35–60.
Cattermole HR, Hardy JRW, Gregg PJ. The footballers fracture. J Sports Med. 1996;30:171–5.
Harper TE, Roberts JR, Jones R. Driver Swingweighting: a worthwhile process? Proc Inst Mech Eng. Part B - J. Eng. Manuf. 2005;219(5):385–93.
Kramer M, Burrow K, Heger A. 17th STAPP car crash conference, Coronado, 1973 SAE730966 81–100.
McElhaney JH. J Appl Physiol. 1966;31:1231–6.
Philippens M, Wismans J. Proceedings of 1989 international conference on the biomechanics of impacts, Stockholm, 1989. p. 65–76.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag London
About this chapter
Cite this chapter
Hainsworth, S.V. (2013). How Much Force?. In: Rutty, G. (eds) Essentials of Autopsy Practice. Springer, London. https://doi.org/10.1007/978-0-85729-519-4_7
Download citation
DOI: https://doi.org/10.1007/978-0-85729-519-4_7
Published:
Publisher Name: Springer, London
Print ISBN: 978-0-85729-518-7
Online ISBN: 978-0-85729-519-4
eBook Packages: MedicineMedicine (R0)