Abstract
Computer-assisted surgery (CAS) is beginning to emerge as one of the most important technologies in orthopedic surgery. Many of the initial applications of this technology have focused on adult reconstructive surgery of the knee. The value of CAS in total knee arthroplasty (TKA) has been established in many studies. Minimally invasive surgical (MIS) techniques for performing TKA are also receiving extensive and intensive attention. The goals of this chapter are to (1) present the rationale for the use of image-free CAS in knee surgery, (2) explain the rationale for combining CAS with MIS techniques, (3) describe the basic components of an image-free navigation system, (4) illustrate a typical CAS MIS technique, and (5) present the initial results using this technique.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Aglietti P, Buzzi R. Posteriorly stabilized total-condylar knee replacement. J Bone Joint Surg 1988; 70-B(2): 211–216
Ayers DC, Dennis DA, Johanson NA, et al. Common complications of total knee arthroplasty. J Bone J Surg 1997; 2(79A): 278–311
Bargren JH, Blaha JD, Freeman MAR. Alignment in total knee arthroplasty: correlated biomechanical and clinical observations. Clin Orthop Relat Res 1983 Mar;(173): 178–183
Berger RA, Crosset LS, Jacobs JJ. Malrotation causing patellofe-moral complications after total knee arthroplasty. Clin Orthop Relat Res 1998 Nov;(356): 144–153
Cartier P, Sanouillier JL, Frelsamer RP. Unicompartmental knee arthroplasty surgery. 10-year minimum follow-up period. J Arthro-plasty 1996; 11: 782–788
Dorr LD, Boiardo RA. Technical considerations in total knee arthroplasty. Clin Orthop Relat Res 1986 Apr;(205): 5–11
Ecker ML, Lotke PA, Windsor RE, et al. Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop Relat Res 1987 Mar;(216): 151–158
Fehring TK, Odum S, Griffin WL, Mason JB, Naduad M. Early failures in total knee arthroplasty. Clin Orthop Relat Res 2001 Nov;(392): 315–318
Feng EL, Stulberg SD, Wixson RL. Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. Clin Orthop Relat Res 1994 Feb;(299): 60–71
Goodfellow JW, O’Connor JJ. Clinical results of the Oxford knee. Clin Orthop Relat Res 1986 Apr;(205): 21–24
Hsu HP, Garg A, Walker PS, Spector M, Ewald FC. Effect on knee component alignment on tibial load distribution with clinical correlation. Clin Orthop Relat Res 1989 Nov;(248): 135–144
Insall JW. Surgical approaches to the knee. In Insall JN (ed), Surgery of the Knee, Churchill Livingston, New York, 1984, pp. 41–54
Insall JN, Binzzir R, Soudry M, Mestriner LA. Total knee arthroplasty. Clin Orthop Relat Res 1985 Jan-Feb;(192): 13–22
Insall JN, Ranawat CS, Aglietti P, Shine J. A comparison of four models of total knee-replacement prosthesis. J Bone Joint Surg 1976; 58A: 754–765
Jeffcote B, Shakespeare D. Varus/valgus alignment of the tibial component in total knee arthroplasty. Knee 2003; 10(3): 243–247
Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. J Bone Joint Surg 1991; 73B: 709–714
Jiang CC, Insall JN. Effect of rotation on the axial alignment of the femur. Clin Orthop Relat Res 1989 Nov;(248): 50–56
Laskin RS. Alignment of the total knee components. Orthopedics 1984; 7: 62
Laskin RS. Total condylar knee replacement in patients who have rheumatoid arthritis. A ten year follow-up study. J Bone Joint Surg 1990; 72A: 529–535
Laskin RS, Turtel A. The use of an intramedullary tibial alignment guide in total knee replacement arthroplasty. Am J Knee Surg 1989; 2: 123
Nuno-Siebrecht N, Tanzer M, Bobyn JD. Potential errors in axial alignment using intramedullary instrumentation for total knee arthroplasty. J Arthroplasty 2000; 15: 228–230
Oswald MH, Jacob RP, Schneider E, Hoogewoud H. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 1993; 8: 419–426
Petersen TL, Engh GA. Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 1988; 3: 67–72
Piazza SJ, Delp SL, Stulberg, SD, Stern SJ. Posterior tilting of the tibial component decreases femoral rollback in posterior-substituting knee replacement. J Orthop Res 1998; 16: 264–270
Ranawat CS, Boachie-Adjei O. Survivorship analysis and results of total condylar knee arthroplasty. Clin Orthop Relat Res 1988 Jan;(226): 6–13
Rand JA, Coventry MB. Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop Relat Res 1988 Jul;(232): 168–173
Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 1994 Feb;(299): 153–156
Ritter M, Merbst WA, Keating EM, Faris PM. Radiolucency at the bone-cement interface in total knee replacement. J Bone Joint Surg 1991; 76A: 60–65
Sharkey PF, Hozack WJ, Rothman RH, et al. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 2002 Nov;(404): 7–13
Stern SH, Insall JN. Posterior stabilized prosthesis: results after follow-up of 9–12 years. J Bone Joint Surg 1992; 74A: 980–986
Teter KE, Bergman D, Colwell CW. Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop Relat Res 1995 Dec;(321): 106–110
Tew M, Waugh W. Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg 1985; 67B: 551–556
Townley CD. The anatomic total knee: instrumentation and alignment technique. The Knee: papers of the First Scientific Meeting of the Knee Society. Baltimore University Press, Baltimore, MD, 1985, pp. 39–54
Vince KIG, Insall JN, Kelly MA. The total condylar prosthesis. 10 to 12 year results of a cemented knee replacement. J Bone Joint Surg 1989; 71B: 93–797
Wasielewski RC, Galante JO, Leighty R, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 1994 Feb;(299): 31–43
Hungerford DS, Kenna RV. Preliminary experience with a total knee prosthesis with porous coating used without cement. Clin Orthop Relat Res 1983 Jun;(176):95–107
Currie J, Varshney A, Stulberg SD, Adams A, Woods O. The reliability of anatomic landmarks for determining femoral implant = rotation in TKA surgery: implications for CAOS TKA. Presented at the Annual Meeting of Mid-America Orthopaedic Association, Amelia Island, FL, 2005
Delp SL, Stulberg SD, Davies B, Picard F, Leitner F. Computer assisted knee replacement. Clin Orthop Relat Res 1998 Sep; (354): 49–56
Eichorn H.-J. Image-free navigation in ACL replacement with the OrthoPilot System. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 387–396
Ellis RE, Rudan JF, Harrison, MM. Computer-assisted high tibial osteotomies. In DiGioia AM, Jaramaz B, Picard R, Nolte PL (eds), Computer and Robotic Assisted Knee and Hip Surgery, Oxford University Press, Oxford, 2004, pp. 197–212
Fadda M, Bertelli D, Martelli S, et al. Computer assisted planning for total knee arthroplasty. Proceedings of the First Joint Conference on Computer Vision, Virtual Reality and Robotics in Medicine and Medial Robotics and Computer Assisted Surgery, Grenoble, France. Springer, Berlin, 1997, pp. 619–628
Froemel M, Portheine F, Ebner M, Radermacher K. Computer assisted template based navigation for total knee replacement. North American Program on Computer Assisted Orthopaedic Surgery, 6–8 July 2001, Pittsburgh, PA
Garbini JL, Kaiura RG, Sidles JA, Larson RV, Matsen FA. Robotic instrumentation in total knee arthroplasty. 33rd Annual Meeting, Orthopaedic Research Society, 19–22 January 1987, San Francisco, CA
Garg A, Walker PS. Prediction of total knee motion using a three-dimensional computer graphics model. J Biochem 1990; 23: 45–58
Jenny JY, Boeri C. Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 2004; 75(1): 74–77
Julliard R, Lavallee S, Dessenne V. Computer assisted anterior cruciate ligament reconstruction of the anterior cruciate ligament. Clin Orthop Relat Res 1998 Sep;(354): 57–64
Julliard R, Plaweski S, Lavallee S. ACL surgetics: an efficient computer-assisted technique for ACL reconstruction. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 405–411
Kaiura RG. Robot assisted total knee arthroplasty investigation of the feasibility and accuracy of the robotic process. Master’s Thesis, Mechanical Engineering, University of Washington, Seattle, WA, 1986
Kienzle TC, Stulberg SD, Peshkin M, et al. A computer-assisted total knee replacement surgical system using a calibrated robot. Orthopaedics. In Taylor RH, et al. (eds), Computer Integrated Surgery. MIT Press, Cambridge, MA 1996, pp. 409–416
Kinzel V, Scaddan M, Bradley B, Shakespeare D. Varus/valgus alignment of the femur in total knee arthroplasty. Can accuracy be improved by pre-operative CT scanning? Knee 2004; 11(3): 197–201
Klos TVS, Habets RJE, Banks AZ, Banks SA, Devilee RJJ, Cook FF. Computer assistance in arthroscopic anterior cruciate ligament reconstruction. In DiGioia AM, Jaramaz B, Picard R, Nolte PL (eds), Computer and Robotic Assisted Knee and Hip Surgery, Oxford University Press, Oxford, 2004, pp. 229–234
Krackow K, Serpe L, Phillips MJ, et al. A new technique for determining proper mechanical axis alignment during total knee arthroplasty. Orthopedics 1999; 22(7): 698–701
Kuntz M, Sati M, Nolte LP, et al. Computer assisted total knee arthroplasty. International symposium on CAOS: 2000, February 17–19, Davos, Switzerland
Leitner F, Picard F, Minfelde R, et al. Computer-assisted knee surgical total replacement. First Joint Conference of CVRMed and MRCAS, Grenoble, France. Springer, Berlin, 1997, pp. 629–638
Leitner F, Picard F, Minfelde R, et al. Computer assisted knee surgical total replacement. Proceedings of the First Joint Conference on Computer Vision, Virtual Reality and Robotics in Medicine and Medical Robotics and Computer Assisted Surgery, Grenoble, France.. Springer, Berlin, 1997, pp. 630–638
Martelli M, Marcacci M, Nofrini L, LA Palombara F, Malvisi A, Iacono F, Vendruscolo P, Pierantoni M. Computer- and robot-assisted total knee replacement: analysis of a new surgical procedure. Ann Biomed Eng 2000; 28(9): 1146–1153
Matsen FA, Garbini JL, Sidles JA. Robotic assistance in orthopaedic surgery. A proof of principle using distal femoral arthroplasty. Clin Orthop Relat Res 1993 Nov;(296): 178–186
Nizard R. Computer assisted surgery for total knee arthroplasty. Acta Orthop Belg 2002; 68(3): 215–230. [Review]
Noble PC, Sugano N, Johnston JD, Thompson MT, Conditt MA, Engh CA Sr, Mathis KB. Computer simulation: how can it help the surgeon optimize implant position? Clin Orthop Relat Res 2003 Dec;(417): 242–252. [Review]
Peterman J, Kober R, Heinze R, Frolich JJ, Heeckt PF, Gotzen L. Computer-assisted planning and robot assisted surgery in anterior cruciate ligament reconstruction. Oper Techn Orthop 2000; 10: 50–55
Picard F, Leitner F, Raoult O, Saragaglia D. Computer assisted knee replacement. Location of a rotational center of the knee. Total knee arthroplasty. International Symposium on CAOS, February 2000
Picard F, Moody JE, DiGioia AM, Jaramaz B, Plakseychuk AY, Sell D. Knee reconstructive surgery: preoperative model system. In DiGioia AM, Jaramaz B, Picard R, Nolte PL (eds), Computer and Robotic Assisted Knee and Hip Surgery, Oxford University Press, Oxford, 2004, pp. 139–156
Picard F, Moody JE, DiGioia AM, Martinek V, Fu FH, Rytel MJ, Nikou C, LaVarca RS, Jaramaz B. ACL reconstruction-preoperative model system. In DiGioia AM, Jaramaz B, Picard R, Nolte PL (eds), Computer and Robotic Assisted Knee and Hip Surgery, Oxford University Press, Oxford, 2004, pp. 213–228
Radermacher K, Staudte HW, Rau G. Computer assisted orthopaedic surgery with image-based individual templates. Clin Orthop Relat Res 1998 Sep;(354): 28–38
Saragaglia D, Picard F. Computer-assisted implantation of total knee endoprosthesis with no pre-operative imaging: the kinematic model. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 226–233
Sati M, Staubli HU, Bourquin Y, Kunz M, Nolte LP. CRA hip and knee reconstructive surgery: ligament reconstructions in the knee-intra-operative model system (non-image based). In DiGioia AM, Jaramaz B, Picard R, Nolte PL (eds), Computer and Robotic Assisted Knee and Hip Surgery, Oxford University Press, Oxford, 2004, pp. 235–256
Siebert W, Mai S, Kober R, Heeckt PF. Technique and first clinical results of robot-assisted total knee replacement. Knee 2002; 9(3): 173–180
Stulberg SD, Eichorn J, Saragaglia D, Jenny J-Y. The rationale for and initial experience with a knee suite of computer assisted surgical applications. Third International CAOS Meeting, June, 2003, Marbella, Spain
Stulberg SD, Picard F, Saragaglia D. Computer assisted total knee arthroplasty. Operative techniques. Orthopaedics 2000; 10(1): 25–39
Stulberg SD, Saragaglia D, Miehlke R. Total knee replacement: navigation technique intra-operative model system. In DiGioia AM, Jaramaz B, Picard R, Nolte PL (eds), Computer and Robotic Assisted Knee and Hip Surgery, Oxford University Press, Oxford, 2004, pp. 157–178
Stulberg SD, Sarin V, Loan P. X-ray vs. computer assisted measurement techniques to determine pre and post-operative limb alignment in TKR surgery. Proceedings of the Fourth Annual American CAOS meeting, July 2001, Pittsburgh, PA
Tibbles L, Lewis C, Reisine S, Rippey R, Donald M. Computer assisted instruction for preoperative and postoperative patient education in joint replacement surgery. Comput Nurs 1992; 10(5): 208–212
Koyonos L, Granieri M, Stulberg SD. At what steps in performance of a TKA do errors occur when manual instrumentation is Used. Presented at the Annual Meeting of American Academy of Orthopaedic Surgeons, 2005, Washington, DC
Stulberg SD, Koyonos L, McClusker S, Granieri M. Factors affec-ting the accuracy of minimally invasive TKA. Presented at the Annual Meeting of American Academy of Orthopaedic Surgeons, 2005, Washington, DC
Tria AJ Jr. Minimally invasive total knee arthroplasty: the importance of instrumentation. Orthop Clin North Am 2004; 35(2): 227–234
Briard JL, Stindel E, Plaweski S, et al. CT free navigation with the LCS surgetics station: a new way of balancing the soft tissues in TKA based on bone morphing. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 274–280
Konermann WH, Kistner S. CT-free navigation including soft-tissue balancing: LCS-TKA and vector vision systems. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 256–265
Strauss JM, Ruther W. Navigation and soft tissue balancing of LCS total knee arthroplasty. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 266–273
Bathis H, Perlick L, Tingart M, Luring C, Perlick C, Grifka J.Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty. Int Orthop 2004; 28(2): 87–90
Bohler M, Messner M, Glos W, Riegler ML. Computer navigated implantation of total knee prostheses: a radiological study. Acta Chir Aust 2000; 33(Suppl): 63
Clemens U, Konermann WH, Kohler S, Kiefer H, Jenny JY, Miehlke RK. Computer-assisted navigation with the OrthoPilot System using the search evolution TKA prosthesis. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 236–241
Jenny JY, Boeri C. Computer-assisted total knee prosthesis implantation without preoperative imaging. A comparison with classical instrumentation. Presented at the Fourth Annual North American Program on Computer Assisted Orthopaedic Surgery, 2000, Pittsburgh, PA
Jenny JY, Boeri C. Implantation d’une prothese totale de genou assistee par ordinateur. Etude comparative cas-temoin avec une instrumentaiton traditionnelle. Rev Chir Orthop 2001; 87: 645–652
Jenny JY, Boeri C. Navigated implantation of total knee prostheses: a comparison with conventional techniques. Z Orthop Ihre Grenzgeb 2001; 139: 117–119
Jenny JY, Boeri C. Unicompartmental knee prosthesis. A case-control comparative study of two types of instrumentation with a five year follow-up. J Arthroplasty 2002; 17: 1016–1020
Jenny JY, Boeri C. Unicompartmental knee prosthesis implantation with a non-image based navigation system. In DiGioia AM, Jaramaz B, Picard R, Nolte PL (eds), Computer and Robotic Assisted Knee and Hip Surgery, Oxford University Press, Oxford, 2004, pp. 179–188
Konermann WH, Sauer MA. Postoperative alignment of conventional and navigated total knee arthroplasty. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 219–225
Lampe F, Hille E. Navigated implantation of the Columbus total knee arthroplasty with the OrthoPilot System: Version 4.0. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 248–253
Mattes T, Puhl W. Navigation in TKA with the Navitrack System. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 293–300
Miehlke RK, Clemens U, Jens J-H, Kershally S. Navigation in knee arthroplasty: preliminary clinical experience and prospective comparative study in comparison with conventional technique. Z Orthop Ihre Grenzgeb 2001; 139: 1109–1129
Miehlke RK, Clemens U, Kershally S. Computer integrated instrumentation in knee arthroplasty: a comparative study of conventional and computerized technique. Fourth Annual North American Program on Computer Assisted Orthopaedic Surgery, Pittsburgh, PA, 2000, pp. 93–96
Nishihara S, Sugano N, Ikai M, Sasama T, Tamura Y, Tamura S, Yoshikawa H, Ochi T. Accuracy evaluation of a shape-based registration method for a computer navigation system for total knee arthroplasty. J Knee Surg 2003; 16(2): 98–105
Perlick L, Bathis H, Luring C, Tingart M, Grifka J. CT based and CT-free navigation with the brainLAB vector vision system in total knee arthroplasty. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 304–310
Perlick L, Bathis H, Tingart M, Perlick C, Grifka J. Navigation in total-knee arthroplasty: CT-based implantation compared with the conventional technique. Acta Orthop Scand 2004; 75(4): 464–470
Perlick L, Bathis H, Tingart M, Kalteis T, Grifka J. [Usability of an image based navigation system in reconstruction of leg alignment in total knee arthroplasty - results of a prospective study] Biomed Tech (Berl) 2003; 48(12): 339–343. [German]
Picard F. Leitner F, Raoult O, Saragaglia D, Cinquin P. Clinical evaluation of computer assisted total knee arthroplasty. Second Annual North American Program on Computer Assisted Ortho-paedic Surgery, Pittsburgh, PA, 1998, pp. 239–249.
Saragaglia D, Picard F, Chaussard C, et al. Computer-assisted knee arthroplasty: comparison with a conventional procedure: results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 2001; 87: 215–220
Saragagaglia D, Picard F, Chaussard D, Montbarbon E, Leitner F, Cinquin P. Computer assisted total knee arthroplasty: comparison with a conventional procedure. Results of 50 cases prospective randomized study. Presented at the First Annual Meeting of Computer Assisted Orthopaedic Surgery, Davos, Switzerland, 2001
Sparmann M, Wolke B. Knee endoprosthesis navigation with the Stryker System. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 319–323
Sparmann M, Wolke B. [Value of navigation and robot-guided surgery in total knee arthroplasty]. Orthopade 2003; 32(6): 498–505. [German]
Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O. Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 2004 Sep;(426): 180–186
Stulberg SD. CAS-TKA reduces the occurrence of functional outliers. Presented at the Annual Meeting of Mid-America Orthopaedic Association, Amelia Island, FL, 2005
Stulberg SD, Loan P, Sarin V. Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg 2002; 84-A(Suppl 2): 90–98.
Wiese M, Rosenthal A. Bernsmann K. Clinical experience using the SurgiGATE System. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 400–404
Wixson RL. Extra-medullary computer assisted total knee replacement: towards lesser invasive surgery. In Steihl JB, Konermann WH, Haaker RG (eds), Navigation and Robotics in Total Joint and Spine Surgery, Springer, Berlin, 2004, pp. 311–318
Bathis H, Perlick L, Luring C, Kalteis T, Grifka J. [CT-based and CT-free navigation in knee prosthesis implantation. Results of a prospective study] Unfallchirurg 2003; 106(11): 935–940. [German]
Insall J, Scott N, Surgery of the knee, Chapter 95. Elsevier, Philadelphia, 2006, pp. 1675–1688
Mahfouz MR, Hoff WA, Komistek RD, Dennis DA. A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Trans Med Imaging 2003; 22(12): 1561–1574
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer Science+Business Media, LLC
About this chapter
Cite this chapter
Stulberg, S.D. (2010). Minimally Invasive Total Knee Arthroplasty with Image-Free Navigation. In: Scuderi, G., Tria, A. (eds) Minimally Invasive Surgery in Orthopedics. Springer, New York, NY. https://doi.org/10.1007/978-0-387-76608-9_76
Download citation
DOI: https://doi.org/10.1007/978-0-387-76608-9_76
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-0-387-76607-2
Online ISBN: 978-0-387-76608-9
eBook Packages: MedicineMedicine (R0)