Skip to main content

Effect of Different Visual Feedback Conditions on Maximal Grip-Strength Assessment

  • Conference paper
XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013

Part of the book series: IFMBE Proceedings ((IFMBE,volume 41))

Abstract

Grip strength was assessed using the Grip-ball dynamometer for twenty-one subjects (11 men and 10 women). Five different verbal feedback conditions were tested: no visual feedback (NVF), non-quantified visual feedback (IVF), accurate visual feedback (CVF), and both over-estimated (OVF) and under-estimated (OVF) visual feedback. In the latter three conditions, subjects were presented with a target force to strive for. Significantly greater grip strength was observed for the CVF condition in comparison with the NVF and IVF conditions (6% increase for both comparisons, p<0.05). No other significant differences were observed. The magnitude of the differences suggests that visual feedback could be of clinical relevance when maximal grip strength testing is performed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer International Publishing Switzerland

About this paper

Cite this paper

Chkeir, A., Jaber, R., Hewson, D.J., Hogrel, J.Y., DuchĂȘne, J. (2014). Effect of Different Visual Feedback Conditions on Maximal Grip-Strength Assessment. In: Roa Romero, L. (eds) XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013. IFMBE Proceedings, vol 41. Springer, Cham. https://doi.org/10.1007/978-3-319-00846-2_279

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-00846-2_279

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-00845-5

  • Online ISBN: 978-3-319-00846-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics