Abstract
The treatment of malignant tumors involving the pelvic area is a challenging problem in musculoskeletal oncology due to the complex pelvic anatomy and the often large tumor size at presentation. The use of navigation systems has effectively increased surgical precision aiming at optimal preservation of pelvic structures without compromising oncologic outcome by means of improved visibility of the surgical field, and enabling intraoperative display and 3D reproduction of preoperatively determined pelvic osteotomy and resection levels. In the following sections, current developments in computer-assisted pelvic surgery are reviewed and possible fields of application, as well as limitations of navigation systems, are discussed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Amiot L P, Labelle H, De Guise JA, Sati M, Brodeur P, Rivard CH (1995) Computer-assisted pedicle screw fixation. A feasibility study. Spine 20:208–1212
Amiot L P, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar and sacral spine. Spine 25:606–614
Azuma RT (1997) A survey of augmented reality. Presence Teleoperator Virtual Environments. 6:355–385
Bacci G, Ferrari S, Mercuri M, Longhi A, Giacomini S, Forni C, Bertoni F, Manfrini M, Barbieri E, Lari S, Donati D (2003) Multimodal therapy for the treatment of nonmetastatic Ewing's sarcoma of pelvis. J Pediatr Hematol Oncol 25:118–124
Bacci G, Ferrari S, Mercuri M, et al.: Multimodal therapy for the treatment of nonmetastatic Ewing's sarcoma ofpelvis. J Pediatr Hematol Oncol 2003; 25:118–124.
Bächler R, Bunke H, Nolte LP (2001) Restricted surface matching: numerical optimization and technical evaluation. Comput Aided Surg 6:143–152
Bottland M, Marsh JL, Brown TD (1997) Accuracy of screw displacement axis detection by DC electromagnetic motion tracking. Oral presentation for the departments of Orthopedic Surgery and Biomedical Engineering, University of Iowa, February 1997
Bowersox JC, Bucholz RD, Delp SL (1997) Excerpts from the final report for the Second International Workshop on Robotics and Computer Assisted Medical Interventions. Comput Aided Surg 2:69–101
Campanacci M, Capanna R (1991) Pelvic resections: the Rizzoli Institute experience. Orthop Clin North Am 22:65–86
Carter TJ, Sermesant M, Cash DM, Barratt DC, Tanner C, Hawkes DJ (2005) Application of soft tissue modelling to image-guided surgery. Med Eng Phys 27:893–909
Chopra SS, Hünerbein M, Eulenstein S, Lange T, Schlag PM, Beller S (2007) Development and validation of a three dimensional ultrasound based navigation system for tumor resection. Eur J Surg Oncol 34:456–461
Court C, Bosca L, Le Cesne A, Nordin J Y, Missenard G (2006) Surgical excision of bone sarcomas involving the sacroiliac joint. Clin Orthop Relat Res 451:189–194
Dessenne V, Lavallée S, Julliard R, Orti R, Martelli S, Cinquin P (1995) Computer assisted knee anterior cruciate ligament reconstruction: first clinical tests. J Image Guid Surg 1:59–64
Enneking WF (1966) Local resection of malignant lesions of the hip and pelvis. J Bone Joint Surg Am 48:991–1007
Enneking W F, Dunham WK (1978) Resection and reconstruction for primary neoplasms involving the innominate bone. J Bone Joint Surg 60A:731–746
Enneking WF, Dunham WK, Gebhardt M, Malawar M, Pritchard D (1990) A system for the classification of skeletal resections. Chir Organi Mov 75[1 Suppl]:217–240
Fehlberg S, Lange T, Eulenstein S, Schlag PM, Tunn PU (2006) Navigationsgestützte Resektion maligner Knochentumoren des Beckens. Onkologe 12:152–157
Fichtinger G, Deguet A, Masamune K, Fischer G, Iordachita I, Balogh E, Masamune K, Taylor RH, Fayad LM, de Oliveira M, Zinreich SJ (2004) Needle insertion in CT scanner with image overlay—cadaver studies. In: Medical image computing and computer assisted intervention (MICCAI). vol 3217. Lecture notes in computer science (LNCS). Springer, Heidelberg Berlin New York, pp 795–803
Fuchs B, O'Connor MI, Kaufman KR, Padgett DJ, Sim FH (2002) Iliofemoral arthrodesis and pseu-darthrosis: along-term functional outcome evaluation. Clin Orthop Relat Res 397:29–35
Glozman D, Shoham M, Fischer A (2001) A surface matching technique for robot-assisted registration. Comput Aided Surg 6:259–269
Hoffmann C, Gosheger G, Gebert C, Jürgens H, Winkelmann W (2006) Functional results and quality of life after treatment of pelvic sarcomas involving the acetabulum. J Bone Joint Surg Am 88:575–582
Hüfner T, Kfuri M, Galanski M, Bastian L, Loss M, Pohlemann T, Krettek C (2004) New Indications for computer-assisted surgery—tumor resection in the pelvis. Clin Orthop Relat Res 426:219–225
Kai J, Shiomi H, Sasama T, Sato Y, Inoue T, Tamura S, Inoue T (1998) Optical high-precision three-dimensional position measurement system suitable for head motion tracking in frameless stereotactic radiosurgery. Comput Aided Surg 3:257–263
Kawai A, Healey JH, Boland PJ, Lin P P, Huvos AG, Meyer PA (1998a) Prognostic factors for patients with sarcomas of the pelvic bones. Cancer 82:851–859
Kawai A, Huvos AG, Meyers PA, Healey JH (1998b) Osteosarcoma of the pelvis: oncologic results of 40 patients. Clin Orthop Relat Res 348:196–207
Khadem R, Yeh CC, Sadeghi-Tehrani M, Bax MR, Johnson JA, Welch JN, Wilkinson EP, Shahidi R (2000) Comparative tracking error analysis of five different optical tracking systems. Comput Aided Surg 5:98–107
Kollender Y, Shabat S, Bickels J, Flusser G, Isakov J, Neuman Y, Cohen I, Weyl-Ben-Arush M, Ramo N, Meller I (2000) Internal hemipelvectomy for bone sarcomas in children and young adults: surgical considerations. Eur J Surg Oncol 26:398–404
Krettek C, Geerling J, Bastian L (2004) Computer aided tumor resection in the pelvis. Injury 35[Suppl 1]:SA79–83
Langlotz F, Stucki M, Bächler R (1997) The first twelve cases of computer assisted periacetabular osteotomy. Comput Aided Surg 2:317–326
Langlotz F, Bächler R, Berlemann U, Nolte L P, Ganz R (1998) Computer assistance for pelvic osteotomies. Clin Orthop Relat Res 354:92–102
Langlotz F, Hinsche AF, Smith RM (2002) Hip and pelvic osteotomies. In: Di Gioia AM, Jaramaz B, Picard F, Nolte LP (eds) Hip and knee surgery— navigation, robotics, and computer assisted surgical tools. Oxford University Press, Oxford
Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. Proc ACM SIGGRAPH 21:163–169
Marmulla R, Lüth T, Mühling J, Hassfeld S (2004) Automated laser registration in image-guided surgery: evaluation of the correlation between laser scan resolution and navigation accuracy. Int J Oral Maxillofac Surg 33:642–648
Maurer CR, Fitzpatrick JM, Wang MY, Galloway RL, Maciunas RJ (1997) Registration of head volume images using implantable fiducial markers. IEEE Trans Med Imaging 16:447–462
Mosheiff R, Weil Y, Khoury A, Liebergall M (2004) The use of computerized navigation in the treatment of gun shot and shrapnel injury. Comput Aided Surg 9:39–43
Ney DR, Fishman EK, Magid D, Robertson DD, Kawashima A (1991) Three-dimensional volumetric display of CT data: effect of scan parameters upon image quality. J Comput Assist Tomogr 15:875–885
Nolte L, Beutler T (2004) Basic principles of CAOS. Injury 35[Suppl 1]:SA6–A16
Ozaki T, Flege S, Kervic M, Lindner N, Maas R, Delling G, Schwarz R, von Hochstetter AR, Salzer-Kuntschik M, Berdel WE, Jürgens H, Exner GU, Reichardt P, Mayer-Steinacker R, Ewerbeck V, Kotz R, Winkelmann W, Bielack SS (2003a) Osteosarcoma of the pelvis: experience of the Cooperative-Osteosarcoma Study Group. J Clin Oncol 21:334–341
Ozaki T, Rodl R, Grosheger G, Hoffmann C, Poremba C, Winkelmann W, Lindner L (2003b) Sacral infiltration in pelvic sarcomas: joint infiltration analysis II. Clin Orthop Relat Res 407:152–158
Pant R, Moreau P, Ilyas I, Paramasivan ON, Younge D (2001) Pelvic limb-salvage surgery for malignant tumors. Int Orthop 24:311–315
Price CH, Jeffree GM (1977) Incidence of bone sarcoma in SW England, 1946–1974, in relation to age, sex, tumour site and histology. Br J Cancer 36:511–522
Pring ME, Weber KL, Unni K, Sim FH (2001) Chondrosarcoma of the pelvis: a review of sixty-four cases. J Bone Joint Surg 83A:1630–1642
Salehi SA, Ondra SL (2000) Use of internal fiducial markers in frameless stereotactic navigational systems during spinal surgery: technical note. Neurosurgery 47:1460–1462
Reijnders K, Coppes MH, van Hulzen ALJ, Gravendeel J P, van Ginkel RJ, Hoekstr HJ (2007) Image guided surgery: new technology for surgery of soft tissue and bone sarcomas. J Cancer Surg 33:390–398
Richenberg JL, Hansell DM (1998) Image processing and spiral CT of the thorax. Brit J Radiol 71:708–716
Schicho K, Figl M, Donat M, Birkfellner W, Seemann R, Wagner A, Bergmann H, Ewers R (2005) Stability of miniature electromagnetic tracking systems. Phys Med Biol 50:2089–2098
Schlaier JR, Warnat J, Dorenbeck U, Proescholdt M, Schebesch KM, Brawanski A (2004) Image fusion of MR images and real-time ultrasonogra-phy: evaluation of fusion accuracy combining two commercial instruments, a neuronavigation system and a ultrasound system. Acta Neurochir (Wien) 146:271–277
Schlöndorff G (1998) Computer assisted surgery: historical remarks. Comput Aided Surg 3:150–152
Simon DA, Lavallée S (1998) Medical imaging and registration in computer-assisted surgery. Clin Orthop Relat Res 354:17–27
Steinmann JC, Herkowitz HN, El-Kommos H, Wesolowsko DP (1993) Spinal pedicle fixation: confirmation of an image-based technique for screw placement. Spine 18:1856–1861
Sucato DJ, Rougraff B, McGrath BE, Sizinski J, Davis M, Papandonatos G, Green D, Szarzanowicz T, Mindell ER (2000) Ewing's sarcoma of the pelvi: long-term survival and functional outcome. Clin Orthop Relat Res 193–201
Sugano N, Sasama T, Sato Y, Nakajima Y, Nishii T, Yonenobu K, Tamura S, Ochi T (2001) Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach. Comput Aided Surg 6:195–203
Tunn PU, Delbrück H, Schlag PM (2003) Ablative Verfahren bei der operativen Behandlung maligner Knochentumoren. Orthopäde 32:955–964
Wingo PA, Tong T, Bolden S (1995) Cancer statistics, 1995. CA Cancer J Clin 45:8
Wirbel RJ, Schulte M, Mutschler WE (2001) Surgical treatment of pelvic sarcomas: oncologic and functional outcome. Clin Orthop Relat Res 190–205
Wirtz CR, Knauth M, Hassfeld S, Tronnier VM, Albert FK, Bonsanto M, Kunze S (1998) Neuronavigation—first experiences with three different commercially available systems. Zentralbl Neurochir 59:14–22
Wong KC, Kumta SM, Chiu KH, Antonio GE, Unwin P, Leung KS (2007a) Precision tumour resection and reconstruction using image-guided computer navigation. J Bone Joint Surg Br 89:943–947
Wong KC, Kumta SM, Chiu KH, Cheung KW, Leung KS, Unwin P, Wong MC (2007b) Computer assisted pelvic tumor resection and reconstruction with a custom-made prosthesis using an innovative adaptation and its validation. Comput Aided Surg 12:225–232
Yang RS, Eckhardt JJ, Eilber FR, Rosen G, Forscher CA, Dorey FJ, Kelly CM, al-Shaikh R (1995) Surgical indications for Ewing's sarcoma of the pelvis. Cancer 76:1388–1397
Yasko A, Rutledge J, Lewis VO, Lin PP (2007) Disease- and recurrence-free survival after surgical resection of solitary bone metastases of the pelvis. Clin Orthop Relat Res 459:128–132
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Fehlberg, S., Eulenstein, S., Lange, T., Andreou, D., Tunn, PU. (2009). Computer-Assisted Pelvic Tumor Resection: Fields of Application, Limits, and Perspectives. In: Tunn, PU. (eds) Treatment of Bone and Soft Tissue Sarcomas. Recent Results in Cancer Research, vol 179. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-77960-5_11
Download citation
DOI: https://doi.org/10.1007/978-3-540-77960-5_11
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-77959-9
Online ISBN: 978-3-540-77960-5
eBook Packages: MedicineMedicine (R0)