Abstract

A specialized data acquisition system is developed, designed, and fabricated at the Budker Institute of Nuclear Physics of the Siberian Branch of the Russian Academy of Sciences for conducting precision experiments with a CMD-3 detector of the VEPP-2000 electron-positron collider. The structure of electronic hardware is described.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. D. Berkaev, A. Kirpotin, T. Koop, et al., “VEPP-2000 Operation with Round beams in the Energy Range from 1 to 2 GeV,” Nucl. Phys. B. Proc. Suppl. 225–227, 303–308 (2012).

    Article  Google Scholar 

  2. B. I. Khazin, “Physics and Detectors for VEPP-2000,” Nucl. Phys. B. Proc. Suppl. 181–182, 376–378 (2008).

    Article  Google Scholar 

  3. G. V. Fedotovich, “CMD-3 Collaboration. CMD-3 Detector for VEPP-2000,” Nucl. Phys. B. Proc. Suppl. 162, 332–338 (2006).

    Article  ADS  Google Scholar 

  4. S. Eidelman, “Physics at VEPP-2000,”/ Nucl. Phys. B. Proc. Suppl. 162, 323–326 (2006).

    Article  ADS  Google Scholar 

  5. G. W. Bennett, B. Bousquet, H. N. Brown, et al., “Muon G-2 Collaboration. Final Report of the Muon E821 Anomalous Magnetic Moment Measurement at BNL,” Phys. Rev. D 73, 072003 (2006).

    Article  ADS  Google Scholar 

  6. A. A. Ruban, V. M. Aulchenko, A. N. Kozyrev, et al., “The CMD-3 Data Acquisition and Control System,” Nucl. Instrum. Meth. A 598(1), 317–322 (2009).

    Article  ADS  Google Scholar 

  7. A. N. Kozyrev, V. M. Aulchenko, L. B. Epshteyn, et al., “The CMD-3 TOM2A DAQ Infrastructure,” J. Instrum. 9, C10016 (2014).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. N. Kozyrev.

Additional information

Original Russian Text © V.M. Aulchenko, D.A. Epifanov, A.N. Kozyrev, I.B. Logashenko, A.S. Popov, A.A. Ruban, A.N. Selivanov, A.A. Talyshev, V.M. Titov, Yu.V. Yudin, L.B. Epshteyn, 2015, published in Avtometriya, 2015, Vol. 51, No. 1, pp. 31–38.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Aulchenko, V.M., Epifanov, D.A., Kozyrev, A.N. et al. Architecture of the system of registration and triggering of the CMD-3 detector. Optoelectron.Instrument.Proc. 51, 24–30 (2015). https://doi.org/10.3103/S8756699015010045