Introduction
Elective intracranial pressure (ICP) monitoring is a useful tool in the diagnosis and evaluation of simple and complex cerebrospinal fluid dynamic disturbances. Whilst many previous research papers have focused on patients undergoing ICP monitoring acutely following traumatic brain injury (TBI), few have looked into the duration of monitoring required to achieve an accurate picture of a patients intracranial dynamics in non acute, elective cases. At our institution we currently complete monitoring for a period of >48hrs.
Methods
A retrospective audit, assessing any patient admitted electively to our institution for ICP monitoring over a 3 month period. Exclusion criteria included acute admissions and patients who underwent a change in their treatment whilst undergoing ICP monitoring (such as CSF shunt valve adjustment / surgical procedures and/or medication changes which could affect ICP i.e. Acetazolamide). ICP results were analysed focusing on median ICP and Median pulse amplitude over three time periods: total data collected v first 48hrs of data collection v first 24hrs of data collection.
Results
18 patients met the desired criteria. Mean length of monitoring was 3 days (range 2-5) for the total number of patients. There was no significant difference between 24hrs and 48hrs duration of monitoring for the median ICP (p=>0.05) and ICP pulse amplitude (p=>0.05).
Conclusion
24 hour monitoring of ICP in elective patients in a stable condition without changes to their current treatment is sufficient to detect mean ICP and pulse amplitude. Further studies may be appropriate to assess if fewer than 24hrs monitoring can also prove an accurate method of monitoring ICP.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Thompson, S., Asif, H., Craven, C. et al. Elective ICP monitoring: how long is long enough?. Fluids Barriers CNS 12 (Suppl 1), P52 (2015). https://doi.org/10.1186/2045-8118-12-S1-P52
Published:
DOI: https://doi.org/10.1186/2045-8118-12-S1-P52