Skip to main content
Log in

Improvements in data analysis obtained by large-area silicon ΔE - E detector telescopes

  • Special Article - Tools for Experiment and Theory
  • Published:
The European Physical Journal A Aims and scope Submit manuscript

Abstract.

The paper describes a few practical methods for the analysis of data obtained by standard thin-thick silicon detector telescopes used in nuclear reaction measurements. The addressed issues are: 1) improvement in double-sided silicon strip detector (DSSSD) calibration based on the fact that each event is registered twice, both in horizontal and vertical strips, 2) improvements in particle identification and 3) simplified mapping of the non-uniformity of the thin detector, without a dedicated measurement of the thickness. The proposed procedures are applied on experimental data obtained for 30MeV 7Li beam induced reactions on LiF and C targets, studied with a detection setup consisting of four telescopes placed at different angles and distances. The proposed methods aim at quicker and more reliable calibration and particle identification.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. O. Tengblad et al., Nucl. Instrum. Methods A 525, 458 (2004)

    Article  ADS  Google Scholar 

  2. D. Torresi et al., Nucl. Instrum. Methods A 713, 11 (2013)

    Article  ADS  Google Scholar 

  3. L. Grassi et al., Nucl. Instrum. Methods A 767, 99 (2014)

    Article  ADS  Google Scholar 

  4. M. Uroić et al., AIP Conf. Proc. 1491, 357 (2012)

    ADS  Google Scholar 

  5. FAZIA Collaboration (L. Bardelli et al.), Nucl. Instrum. Methods A 654, 272 (2011)

    Article  ADS  Google Scholar 

  6. FAZIA Collaboration (N. Le Neindre et al.), Nucl. Instrum. Methods A 701, 145 (2013)

    Article  ADS  Google Scholar 

  7. R.A. Winyard, J.E. Lutkin, G.W. McBeth, Nucl. Instrum. Methods 95, 141 (1971)

    Article  ADS  Google Scholar 

  8. H. Bethe, Ann. Phys. 397, 325 (1930)

    Article  Google Scholar 

  9. B. Davin et al., Nucl. Instrum. Methods A 473, 302 (2001)

    Article  ADS  Google Scholar 

  10. T. Paduszynski et al., Nucl. Instrum. Methods A 547, 464 (2005)

    Article  ADS  Google Scholar 

  11. D.R. Tilley et al., Nucl. Phys. A 745, 155 (2004)

    Article  ADS  Google Scholar 

  12. F. Ajzenberg-Selove, Nucl. Phys. A 523, 1 (1991)

    Article  ADS  Google Scholar 

  13. D.R. Tilley et al., Nucl. Phys. A 636, 249 (1998)

    Article  ADS  Google Scholar 

  14. Y.A. Glukhov et al., Sov. J. Nucl. Phys. 13, 154 (1971)

    Google Scholar 

  15. S. Hamada et al., Phys. Rev. C 49, 3192 (1994)

    Article  ADS  Google Scholar 

  16. M. Milin et al., Nucl. Phys. A 753, 263 (2005)

    Article  ADS  Google Scholar 

  17. M. Freer et al., Phys. Rev. Lett. 96, 042501 (2006)

    Article  ADS  Google Scholar 

  18. M.E. Williams-Norton et al., Phys. Rev. C 12, 1899 (1975)

    Article  ADS  Google Scholar 

  19. C. Lee et al., Phys. Rev. C 60, 024317 (1999)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Uroić.

Additional information

Communicated by D. Pierroutsakou

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Uroić, M., Milin, M., Di Pietro, A. et al. Improvements in data analysis obtained by large-area silicon ΔE - E detector telescopes. Eur. Phys. J. A 51, 93 (2015). https://doi.org/10.1140/epja/i2015-15093-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1140/epja/i2015-15093-0

Keywords

Navigation