Abstract
Myocardial motion analysis and quantification is of utmost importance for analyzing contractile heart abnormalities and it can be a symptom of a coronary artery disease. A fundamental problem in processing sequences of images is the computation of the optical flow, which is an approximation of the real image motion. This paper presents a new algorithm for optical flow estimation based on a spatiotemporal-frequency (STF) approach. More specifically it relies on the computation of the Wigner-Ville distribution (WVD) and the Hough Transform (HT) of the motion sequences. The latter is a well-known line and shape detection method that is highly robust against incomplete data and noise. The rationale of using the HT in this context is that it provides a value of the displacement field from the STF representation. In addition, a probabilistic approach based on Gaussian mixtures has been implemented in order to improve the accuracy of the motion detection. Experimental results in the case of synthetic sequences are compared with an implementation of the variational technique for local and global motion estimation, where it is shown that the results are accurate and robust to noise degradations. Results obtained with real cardiac magnetic resonance images are presented.
Similar content being viewed by others
References
E. Simoncelli, Distributed Representation and Analysis of Visual Motion, Thesis of Massachusetts Institute of Technology, 1993.
S. S. Beauchemin and J. L. Barron, ACM Computing Surveys 27, 433 (1995).
W. I. Meyering, M. A. Gutierrez, S. S. Furuie, et al., Computers in Cardiology 2000 (IEEE Press, Cabridge, 2000), pp. 619–622.
B. K. P. Horn and B. G. Schunck, Artificial Intell. 17, 185 (1981).
G. Aubert and P. Kornprobst, Mathematical Problems in Image Processing: Partial Differential Equations and the Calculus of Variations (Springer-Verlag, New York, 2001).
M. Pingault, D. Pellerin, Signal Processing 84, 709 (2004).
L. Jacobson and H. Wechsler, Comput. Vis. Graph. Image Proc. 38, 29 (1987).
P. A. Laplante and A. D. Stoyenko, Real-Time Imaging: Theory, Techniques, and Applications (IEEE Press, 1996).
E. Wigner, Phys. Rev. 40, 749 (1932).
E. Ville, Cables et Transmission 2A, 61 (1948).
J. Hormigo and G. Cristobal, Adv. Imag. Electron. Phys. 131, 65 (2003).
J. Bigun, Vision with Direction: A Systematic Introduction to Image Processing and Computer Vision (Springer-Verlag, Berlin, 2006).
N. Aggarwal and W. C. Karl, IEEE Trans. Image Proc. 15(3), 582 (2006).
J. S. Marques, in Proceedings of the 1998 European Signal Processing Conference (Island of Rhodes, Greece, 1998)
R. O. Duda and P. E. Hart, Commun. ACM 15(1), (1972).
Author information
Authors and Affiliations
Corresponding author
Additional information
The text was submitted by the authors in English.
Rights and permissions
About this article
Cite this article
Carranza, N., Cristóbal, G., Bayerl, P. et al. Motion estimation of magnetic resonance cardiac images using the Wigner-Ville and hough transforms. Opt. Spectrosc. 103, 877–885 (2007). https://doi.org/10.1134/S0030400X07120077