Skip to main content
Log in

Drift-free iontronic sensing enabled by a creep-free polyelectrolyte elastomer

  • Research Briefing
  • Published:

From Nature Materials

View current issue Submit your manuscript

Soft pressure sensors drift under prolonged high stress because of the creep of soft materials, which causes inaccurate measurements. Now, through molecular-level design, a leakage-free and creep-free polyelectrolyte elastomer is synthesized, and an iontronic sensor using the polyelectrolyte elastomer shows very low signal drift under a high static pressure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1: Drift-free iontronic sensing.

References

  1. Chortos, A., Liu, J. & Bao, Z. Pursuing prosthetic electronic skin. Nat. Mater. 15, 937–950 (2016). A review article that presents materials and skin-like flexible sensors for various applications.

    Article  CAS  PubMed  Google Scholar 

  2. Yang, C. & Suo, Z. Hydrogel ionotronics. Nat. Rev. Mater. 3, 125–142 (2018). A review article that presents the mechanism of the electric double layer in stretchable iontronic devices.

    Article  CAS  Google Scholar 

  3. Kim, H. J., Chen, B., Suo, Z. & Hayward, R. C. Ionoelastomer junctions between polymer networks of fixed anions and cations. Science 367, 773–776 (2020). This paper reports ionoelastomers with ionic species grafted to the polymer networks.

    Article  CAS  PubMed  Google Scholar 

  4. Boyce, M. C. & Arruda, E. M. Constitutive models of rubber elasticity: a review. Rubber Chem. Technol. 3, 504–523 (2000). A review article that presents the constitutive models of rubber elasticity, which correlate the molecular structures of polymer networks to the macroscopic mechanical properties.

    Article  Google Scholar 

  5. Bai, N. et al. Graded intrafillable architecture-based iontronic pressure sensor with ultra-broad-range high sensitivity. Nat. Commun. 11, 209 (2020). This work reports an iontronic sensor with a state-of-the-art sensitivity of up to 3,300 kPa−1.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Additional information

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

This is a summary of: He, Y. et al. Creep-free polyelectrolyte elastomer for drift-free iontronic sensing. Nat. Mater. https://doi.org/10.1038/s41563-024-01848-6 (2024).

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Drift-free iontronic sensing enabled by a creep-free polyelectrolyte elastomer. Nat. Mater. (2024). https://doi.org/10.1038/s41563-024-01851-x

Download citation

  • Published:

  • DOI: https://doi.org/10.1038/s41563-024-01851-x

  • Springer Nature Limited

Navigation