Reduction of Dead Times in Geiger–Müller Counters

  • Letter
  • Published:

From Nature

View current issue Submit your manuscript

Abstract

THE significance of the positive ion sheath, formed in the immediate vicinity of the wire in a Geiger – Müller counter during a discharge, has been discussed by the Montgomeries1 and by Stever2. According to them, the positive ion sheath is directly responsible for the dead time occurring in the counter after each discharge; the dead time is identified with the time necessary for the sheath to move sufficiently far from the wire for the field to be restored to a value at which the next event can be detected. Following this, Simpson3 and Hodson4 investigated the possibility of reducing the dead time by bringing the ion sheath back to the central wire and collecting it there. For this purpose they employed circuits by means of which the wire potential could be switched about 100 volts negative with respect to the cathode for a few microseconds after each discharge. Dead times as low as 20–30 microsec. were obtained in this way.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Montgomery, C. G., and Montgomery, D. D., Phys. Rev., 57, 1030 (1940).

    Article  ADS  CAS  Google Scholar 

  2. Stever, H. G., Phys. Rev., 61, 38 (1942).

    Article  ADS  CAS  Google Scholar 

  3. Simpson, J. A., Phys. Rev., 66, 39 (1944).

    Article  ADS  CAS  Google Scholar 

  4. Hodson, A. L., J. Sci. Instr., 25, 11 (1948).

    Article  ADS  CAS  Google Scholar 

  5. Wantuch, E., Phys. Rev., 71, 646 (1947).

    Article  ADS  CAS  Google Scholar 

  6. Hill, J. M., and Dunsworth, J. V., Nature, 158, 833 (1946).

    Article  ADS  CAS  Google Scholar 

  7. Craggs, J. D. (private communication).

  8. Penning, F. M., K. Acad. Amst. Proc., 33, 841 (1930).

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

COLLINGE, B. Reduction of Dead Times in Geiger–Müller Counters. Nature 162, 853–854 (1948). https://doi.org/10.1038/162853b0

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1038/162853b0

  • Springer Nature Limited

Navigation