Skip to main content
Log in

VCSEL Arrays as Micromanipulators in Chip-Based Biosystems

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

The potential use of vertical cavity surface emitting laser (VCSEL) arrays for applications in cell analysis and tissue engineering is investigated by means of parallel optical trapping and active manipulation of biological cells on microfluidic chips. The simultaneous and independent transport of nine cells using a 3×3 array of VCSELs has been demonstrated experimentally; indicating that larger 2-dimensional array transport using individually addressable tweezers is achievable with VCSEL array devices. The transport properties of VCSEL tweezers have been investigated for various types of cells including 3T3 Murine fibroblasts, yeast, rat primary hepatocytes and human red blood cells. Due to the low relative index of refraction between the biological cell and surrounding medium and the relatively low optical power available with present VCSELs, the Laguerre-Gaussian laser mode output of the VCSEL is more favorable to use in an optical tweezer since the highest intensity is located at the outer ring of the optical aperture, producing stronger optical confinement at lower power levels. For larger biological cells or cells with a lower relative index of refraction, the power limitations of a single VCSEL were overcome through the binning of several VCSELs together by combining the outputs of a sub-array of VCSELs into a collective optical tweezer. A comprehensive analysis and simulation of how the VCSELs’ pitch and output beam divergence influence the operation of the resultant optical tweezer array is presented along with our experimental data. Employing the methods of parallel array transport and the binning of multiple VCSEL outputs, allows for the manipulation and spatial arrangement of different types of cells in a co-culture so as to facilitate the formation of engineered tissues.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • A. Ashkin, Biophys. J. 61, 569-582 (1992).

    Google Scholar 

  • A. Ashkin, J.M. Dziedzic, J.E. Bjorkholm, and S. Chu, Opt. Lett. 11, 288-290 (1986).

    Google Scholar 

  • S. Bhatia and C. Chen, Biomedical Microdevices 2(2), 131-144 (1999).

    Google Scholar 

  • S. Bhatia, M.L. Yarmush, and M. Toner, in Methods in Molecular Medicine: Tissue Engineering Methods and Protocols, eds. J.R. Morgan and M. Yarmush (Humana Press, New Jersey, 1998), pp. 349-363.

    Google Scholar 

  • S.M. Block, Nature 360, 493-495 (1992).

    Google Scholar 

  • S.M. Block, in Noninvasive Technologies in Cell Biology, eds. J.K. Foskett and S. Grinstein (Wiley, New York, 1990), pp. 375-402.

    Google Scholar 

  • L. Breckenridge, P. Clark, P. Connolly, A.S.G. Curtis, J.A.T. Dow, R. Wilson, R. Lind, and C.D.W. Wilkinson, in Synthetic Microstructures in Biological Research, eds. J.M. Schnur, M. Peckerar, and H.M. Stratton (Plenum, New York, 1992), pp. 201-206.

    Google Scholar 

  • E. Delamarche, A. Bernard, H. Schmid, B. Michel, and H. Biebuyck, Science 276, 779-781 (1997).

    Google Scholar 

  • D.C. Duffy, R.J. Jackman, K.M. Vaeth, K.F. Jensen, and G.M. Whitesides, Adv. Mater. 11(7), 546 (1999).

    Google Scholar 

  • J.C Dunn, R.G. Tompkins, and M.L. Yarmush, Biotechnol. Prog. 7, 237-245 (1991).

    Google Scholar 

  • R.A. Flynn, A.L. Birkbeck, M. Gross, M. Ozkan, B. Shao, M.M. Wang, and S.C. Esener, Sens. Actuators B 87(2), 241-245 (2002).

    Google Scholar 

  • A. Folch, A. Ayon, O. Hurtado, M.A. Schmidt, and M. Toner, J. Biomech. Eng. 121(1), 28-34 (1999).

    Google Scholar 

  • A. Folch, B.H. Jo, D. Beebe, M. Toner and O. Hurtado, J. Biomed. Mater. Res. 52(2), 346-353 (2000).

    Google Scholar 

  • A. Folch and M.A. Smith, J. Microelectromech. Syst. 8(1), 85-89 (1999).

    Google Scholar 

  • E. Hecht, in Hect Optics 2nd Ed., ed. B. Spatz (Addison-Wesley, Massachusetts, 1990), pp. 211-240.

    Google Scholar 

  • K. Hirano, Y. Baba, Y. Matsuzawa, and A. Mizuno, Appl. Phys. Lett. 80(3), 515-517 (2002).

    Google Scholar 

  • R.J. Jackman, J.L. Wilbur, and G.M. Whitesides, Science 269(5224), 664-666 (1995).

    Google Scholar 

  • O. Kibar, R.A. Flynn, and S.C. Esener, OSA Topical Mtg. Spatial Light Modulators Tech. Digests 49-51 (1999).

  • I. Martin, B. Obradovic, S. Treppo, A.J. Grodzinsky, R. Langer, L.E. Freed, and G. Vunjak-Novakovic, Biorheology 37(1–2), 141-147 (2000).

    Google Scholar 

  • A.D. Mehta, M. Rief, J.A. Spudich, A. Smith, and R.M. Simmons, Science 283, 1689-1695 (1999).

    Google Scholar 

  • Y. Ogura, K. Kagawa, and J. Tanida, Appl. Opt. 40(30), 5430-5435 (2001).

    Google Scholar 

  • A.T. O'Neil and M.J. Padgett, Opt. Commun. 193, 45-50 (2001).

    Google Scholar 

  • M. Ozkan, T. Pisanic, J. Scheel, C. Barlow, S.C. Esener, and S. N. Bhatia, The Special Issue of Langmuir on “The Biomolecular Interface” 19(5), 1532-1538 (2003).

    Google Scholar 

  • M. Ozkan, M.M. Wang, and S.C. Esener, Proc. OSA Optics in Computing, OtuC1–2 (2001).

  • A. Schwarz, J.S. Rossier, E. Roulet, N. Mermod, M.A. Roberts, and H.H. Girault, Langmuir 14(19), 5526-5531 (1998).

    Google Scholar 

  • P.O. Seglen, Methods Cell Biol. 13, 29-83 (1976).

    Google Scholar 

  • N.B. Simpson, D. McGloin, K. Dholakia, L. Allen, and M.J. Padgett, J. Mod. Opt. 45, 1943-1949 (1998).

    Google Scholar 

  • I.A. Vorobjev, H. Liang, W.H. Wright, and M.W. Berns, Biophys. J. 64, 533-538 (1993).

    Google Scholar 

  • M.M. Wang, M. Ozkan, P. Wen, M.D. Sanchez, E.P. Ata, C. Ozkan, O. Kibar, and S.C. Esener, Proc. Spie 4260, 68-73 (2001).

    Google Scholar 

  • M.M. Wang, M. Ozkan, E. Ata, P. Wen, M.D. Sanchez, C.S. Ozkan, O. Kibar, and S. C. Esener, BiOS 2001 (2001).

  • W.H. Wright, G.J. Sonek, Y. Tadir, and M.W. Berns, IEEE J.Quantum Electro. 26(12), 2148-2157 (1990).

    Google Scholar 

  • Y.N. Xia and G.M. Whitesides, Annu. Rev. Mater. Sci. 28, 153-184 (1998).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Birkbeck, A.L., Flynn, R.A., Ozkan, M. et al. VCSEL Arrays as Micromanipulators in Chip-Based Biosystems. Biomedical Microdevices 5, 47–54 (2003). https://doi.org/10.1023/A:1024463316562

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1024463316562

Navigation