Abstract
This study examines the integrated electro-coagulation–electro-oxidation (EC–EO) process as an alternative for the treatment of an industrial effluent originating from a soluble coffee production. Experiments were carried out in a laboratory-scale batch cell reactor. Monopolar configuration of electrodes was employed (EC: anode: iron and cathode: stainless steel; EO: anode: boron-doped diamond-Si and cathode: stainless steel), operating in galvanostatic mode. The effect of main operation parameters on decolorization, chemical oxygen demand (COD) and total organic carbon (TOC) degradation and total operation costs was studied. The experimental design, analysis of variance, response surface methodology and constrained optimization algorithms let to establish the most effective operation conditions as follows: for EC (support electrolyte = 4.32 g of Na2SO4/L; current density (J) = 150 A/m2; gap between electrodes = 3 mm; stirring velocity = 350 RPM; electrolysis time (t) = 60 min; and EC’s initial pH (pHi, EC) = 4.71 (the pH of raw wastewater)); and for EO (J = 300 A/m2; t = 100 min; gap between electrodes = 3 mm; stirring velocity = 125 RPM; and pHi, EO = 7.0). The integrated EC–EO process let to accomplish ca. 98% decolorization, ca. 73% of both COD and TOC removal, more oxidized (Average Oxidation State = 0.149), biocompatible (BOD5/COD ratio = 0.404) and less toxic effluent (median lethal concentration of an analyte which causes 50% population death, LC50 lower than 126.43 ppm of raw wastewater), generating 3.782 g/L of sludge, with total operation costs of 8.43 USD/m3. During EC, contaminants with molecular weight (MW) higher than 30 kDa were effectively decomposed. The integrated EO process additionally let to break down pollutants with MW in the range of 5 to 10 kDa. The EC–EO total operation time of 160 min. was required to meet Colombian permissible discharge limits.
Similar content being viewed by others
Change history
11 March 2022
A Correction to this paper has been published: https://doi.org/10.1007/s13762-022-04050-w
References
Akbal F, Camci S (2010) Comparison of electrocoagulation and chemical coagulation for heavy metal removal. Chem Eng Technol 33:1655–1664. https://doi.org/10.1002/ceat.201000091
Ashraf MI, Ateeb M, Khan MH et al (2016) Integrated treatment of pharmaceutical effluents by chemical coagulation and ozonation. Sep Purif Technol 158:383–386. https://doi.org/10.1016/j.seppur.2015.12.048
APHA (2017) Standard methods for the examination of water and wastewater, 23rd edn. American Public Health Association (APHA), Washington, Centennial edition
Brillas E, Martínez-Huitle CA (2015) Decontamination of wastewaters containing synthetic organic dyes by electrochemical methods. An updated review. Appl Catal B Environ 166–167:603–643. https://doi.org/10.1016/j.apcatb.2014.11.016
Cardenas A, Zayas T, Morales U et al (2009) Electrochemical oxidation of wastewaters from the instant coffee industry using a dimensionally stable RuIrCoOx anode. ECS Trans 20(1):291–299. https://doi.org/10.1149/1.3268397
Cañizares P, Jiménez C, Martínez F et al (2007) Study of the electrocoagulation process using aluminum and iron electrodes. Ind Eng Chem Res 46:6189–6195. https://doi.org/10.1021/ie070059f
Chen G (2004) Electrochemical technologies in wastewater treatment. Sep Purif Technol 38:11–41. https://doi.org/10.1016/j.seppur.2003.10.006
Comninellis C, Chen G (2010) Electrochemistry for the environment, 1st edn. Springer, New York, pp 245–263. https://doi.org/10.1007/978-0-387-68318-8
Dobrosz-Gómez I, Gómez-García MÁ (2021) Integration of environmental and economic performance of electro-coagulation-anodic oxidation sequential process for the treatment of soluble coffee industrial effluent. Sci Total Environ 764:142818. https://doi.org/10.1016/j.scitotenv.2020.142818
Garcia-Segura S, Ocon JD, Chong MN (2018) Electrochemical oxidation remediation of real wastewater effluents—a review. Process Saf Environ Prot 113:48–67. https://doi.org/10.1016/j.psep.2017.09.014
Gutierrez-Pulido H, De la Vara R (2013) Análisis y diseño de experimentos, 2nd edn. McGraw-Hill, México
Holt PK, Barton GW, Mitchell CA (2005) The future for electrocoagulation as a localised water treatment technology. Chemosphere 59:355–367. https://doi.org/10.1016/j.chemosphere.2004.10.023
Ibarra HN, GilPavas E, Blatchley ER, Gómez-García MÁ, Dobrosz-Gómez I (2017) Integrated electrocoagulation-electrooxidation process for the treatment of soluble coffee effluent: optimization of COD degradation and operation time analysis. J Environ Manag 200:530–538. https://doi.org/10.1016/j.jenvman.2017.05.095
Kliaugaite D, Yasadi K, Euverink GJ et al (2013) Electrochemical removal and recovery of humic-like substances from wastewater. Sep Purif Technol 108:37–44. https://doi.org/10.1016/j.seppur.2013.01.055
Kondo MM, Leite KUCG, Silva MRA et al (2010) Fenton and photo-fenton processes coupled to uasb to treat coffee pulping wastewater. Sep Sci Technol 45(11):1506–1511. https://doi.org/10.1080/01496395.2010.487451
Lamers LPM, Sarah F, Samborska EM et al (2002) Factors controlling the extent of eutrophication and toxicity in sulfate-polluted freshwater wetlands. Limnol Oceanogr 47:585–593. https://doi.org/10.4319/lo.2002.47.2.0585
Martínez-Huilte CA, Brillas E (2009) Decontamination of wastewaters containing synthetic organic dyes by electrochemical methods: a general review. Appl Catal B Environ 87:105–145. https://doi.org/10.1016/j.apcatb.2008.09.017
Martínez-Huilte CA, Ferro S (2006) Electrochemical oxidation of organic pollutants for the wastewater treatment: direct and indirect processes. Chem Soc Rev 35:1324–1340. https://doi.org/10.1039/b517632h
Montgomery DC (2012) Design and analysis of experiments, 8th edn. Wiley, Hoboken
Novita E (2016) Biodegradability simulation of coffee wastewater using instant coffee. Agric Sci Procedia 9:217–229. https://doi.org/10.1016/j.aaspro.2016.02.138
Oladipo AA, Gazi M (2015) Nickel removal from aqueous solutions by alginate-based composite beads: central composite design and artificial neural network modeling. J Water Proc Eng 8:e81–e91. https://doi.org/10.1016/j.jwpe.2014.12.002
Oladipo AA, Gazi M, Yilmaz E (2015) Single and binary adsorption of azo and anthraquinone dyes by chitosan based hydrogel: Selectivity factor and Box-Behnken process design. b. Chem Eng Res Des 104:264–279. https://doi.org/10.1016/j.cherd.2015.08.018
Oladipo AA, Gazi M (2016) Hydroxyl-enhanced magnetic chitosan microbeads for boron adsorption: parameter optimization and selectivity in saline water. React Funct Polym 109:23–32. https://doi.org/10.1016/j.reactfunctpolym.2016.09.005
Rodrigues N, Bragagnolo N (2013) Identification and quantification of bioactive compounds in coffee brews by HPLC-DAD-MSn. J Food Compos Anal 32:105–115. https://doi.org/10.1016/j.jfca.2013.09.002
Shoup ME (2020) Premiumization leads the way in global coffee market, including instant coffee category. https://goo.gl/evsvz2. Accessed 24 June 2020
Souza F, Quijorna S, Lanza MRV et al (2017) Applicability of electrochemical oxidation using diamond anodes to the treatment of a sulfonylurea herbicide. Catal Today 280:192–198. https://doi.org/10.1016/j.cattod.2016.04.030
Subba Rao AN, Venkatarangaiah VT (2018) Preparation, characterization, and application of Ti/TiO2-NTs/Sb-SnO2 electrode in photo-electrochemical treatment of industrial effluents under mild conditions. Environ Sci Pollut Res 25:11480–11492. https://doi.org/10.1007/s11356-017-1179-4
Takashina TA, Leifeld V, Zelinski DW et al (2018) Application of response surface methodology for coffee effluent treatment by ozone and combined ozone/UV. Ozone Sci Eng 40(4):293–304. https://doi.org/10.1080/01919512.2017.1417112
Thirugnanasambandham K, Sivakumar V, Prakasmaran J (2015) Optimization of process parameters in electrocoagulation treating chicken industry wastewater to recover hydrogen gas with pollutant reduction. Renew Energy 80:101–108. https://doi.org/10.1016/j.renene.2015.01.030
Tokumura M, Ohta A, Znad H et al (2006) UV light assisted decolorization of dark brown colored coffee effluent by photo-Fenton reaction. Water Res 40:3775–3784. https://doi.org/10.1016/j.watres.2006.08.012
Tokumura M, Znad HT, Kawase Y (2008) Decolorization of dark brown colored coffee effluent by solar photo-Fenton reaction: effect of solar light dose on decolorization kinetics. Water Res 42:4665–4673. https://doi.org/10.1016/j.watres.2008.08.007
USDA (2018) Soluble coffee exports. http://cort.as/-Itc. Accessed 29 June 2020
Villanueva M, Bello R, Wareham DG et al (2014) Discoloration and organic matter removal from coffee wastewater by electrochemical advanced oxidation processes. Water Air Soil Pollut 225:2204–2215. https://doi.org/10.1007/s11270-014-2204-6
Zapata A, Malato S, Sánchez-Pérez JA et al (2010) Scale-up strategy for a combined solar photo-Fenton/biological system for remediation of pesticide-contaminated water. Catal Today 151:100–106. https://doi.org/10.1016/j.cattod.2010.01.034
Zayas T, Geissler G, Hernandez F (2007) Chemical oxygen demand reduction in coffee wastewater through chemical flocculation and advanced oxidation processes. J Environ Sci China 19:300–305. https://doi.org/10.1016/s1001-0742(07)60049-7
Zhu X, Ni J, Wei J et al (2011) Scale-up of B-doped diamond anode system for electrochemical oxidation of phenol simulated wastewater in batch mode. Electrochim Acta 56:9439–9447. https://doi.org/10.1016/j.electacta.2011.08.032
Acknowledgements
The authors aknowledge to the Universidad Nacional de Colombia—Sede Manizales for the financial support of this research (Convocatoria nacional de proyectos para el fortalecimiento de la investigación, creación e innovación de la Universidad Nacional de Colombia 2016-2018: Proyecto HERMES-35764; Convocatoria nacional para el apoyo a proyectos de investigación y creación artística de la Universidad Nacional de Colombia 2017-2018: Proyecto HERMES-39077, y Resolución de Vicerrectoría No. 224 del 09 de febrero de 2018). The participation of the students linked to the experimental development of this research is also recognized (S. I. David Narvaez; H. N. Ibarra-Taquez; J. D. Quintero Arias; C. C. Rojas Ruiz; S. Zapata Ceballos; S. Zuluaga Botero).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Additional information
Editorial responsibility: Josef Trögl.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Dobrosz-Gómez, I., Gómez-García, M.Á. Treatment of soluble coffee industrial effluent by electro-coagulation–electro-oxidation process: multiobjective optimization and kinetic study. Int. J. Environ. Sci. Technol. 19, 6071–6088 (2022). https://doi.org/10.1007/s13762-021-03562-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13762-021-03562-1