Abstract
In a large power system voltage sag is considered to be the most common and critical power quality (PQ) issue. With the advent of power-semiconductor devices many PQ devices came into existence. Dynamic voltage restorer (DVR) and distribution static compensator (D-STATCOM) are normally employed as voltage sag mitigation devices. This paper presents a low cost alternative for voltage sag compensation. The proposed device does not require any energy storage device and has only one gate turn-off switch per phase for pulse width modulation, unlike DVR and D-STATCOM that employ DC-to-AC converter topology. Simulation analysis of three phase compensator is performed in MATLAB/Simulink environment and the total harmonic distortion of load voltage when the compensator is functioning during disturbance condition is within the acceptable limits.
Similar content being viewed by others
References
Benachaiba C, Ferdi B (2008) Voltage quality improvement using DVR. Electr Power Qual Util J 14(1):39–45
Bollen MHJ (2001) Voltage sags in three-phase systems. IEEE Power Eng Rev 21(9):8–15
Chang CS, Yang SW, Ho YS (2000) Simulation and analysis of series voltage restorers (SVR) for voltage sag relief. In: IEEE Power Engineering Society Winter Meeting, Singapore, pp 2476–2481
Chen S, Joos G (2000) Series and shunt active power conditioners for compensating distribution system faults. In: Proceedings of the canadian conference on ECE, pp 1182–1186
Chen J, Song S, Wang Z (2006) Analysis and implement of thyristor-based STATCOM. In: International conference on power system technology, Beijing, pp 1–5
Dabroom AM (2008) AC voltage regulator using PWM technique and magnetic flux distribution. In: 13th international power electronics and motion control conference, Poland, pp 1337–1344
Dugan RC, McGranaghan MF, Beaty HW (1996) Electrical power systems quality. McGraw Hill, New York
El-Shamothy MMI, Badran EA, El-Morsi MS (2008) A detailed model of the STATCOM using ATPdraw. In: 12th international middle-east power systems conference, Aswan, Egypt, pp 459–463
Fitzer C, Barnes M, Green P (2004) Voltage sag detection technique for a dynamic voltage restorer. IEEE Trans Ind Appl 40(1):203–212
IEEE Std. 1159-1995 (1995) IEEE recommended practice for monitoring electric power quality, IEEE Std. 1159-1995
Jenkins N (1998) Power electronics applied to the distribution systems. In: IEE colloquium, flexible AC transmission systems, London, pp 311–317
Josephm A, Haneesh AS, Subhash Joshi TG, Unnikrishnan AK (2005) 3-Level STATCOM as a power quality solution of 4 MW induction furnace. In: National power electronics conference, Kharaghpur, India, pp 1–4
Kumar Pradeep, Kumar Niranjan, Akella AK (2014) Six leg DVR topology for compensation of balanced linear loads in three phase four wire system. Int J Syst Assur Eng Manag 5(4):524–533
Lam CS, Wong MC, Han YD (2008) Voltage swell and overvoltage compensation with unidirectional power flow controlled dynamic voltage restorer. IEEE Trans Power Deliv 23(4):2513–2521
Lee DM, Habetler TG, Harley RG, Keister TL, Rostran JR (2007) A voltage sag supporter utilizing a PWM-switched autotransformer. IEEE Trans Power Electron 22(2):626–635
Li YW, Vilathgamuwa DM, Blaabjerg F, Loh PC (2007) A robust control scheme for medium-voltage-level DVR implementation. IEEE Trans Ind Electron 54(4):249–2261
Malik NH, Enamul Haque SM, Shepherd W (1985) Analysis and performance of phase-controlled thyristor ac voltage controllers. IEEE Trans Ind Electron 32(3):192–199
Pan W, Xu Z, Zhang J (2007) Novel configuration of 60-pulse voltage source converter for STATCOM application. Int J Emerg Electr Power Syst 8(5):1–20
Singh B, Adhya A, Mittal AP, Guptha JRP (2006) Power quality enhancement with D-STATCOM for small isolated alternator feeding distribution system. In: International conference on power electronics and drive systems, Delhi, India, pp 274–279
Song YH, Johns AT (1999) Flexible ac transmission systems (FACTS). In: IEE power and energy series 30, London
Strenberger R, Jovcic D (2008) Theoretical framework for minimizing converter losses and harmonics in a multilevel STATCOM. IEEE Trans Power Deliv 23(4):2376–2384
Voraphonpiput N, Chatratana S (2005) STATCOM analysis and controller design for power system voltage regulation. In: IEEE/PES transmission and distribution conference & exhibition, Dailan, China, pp 1–6
Wang B, Venkataramanan G (2009) Dynamic voltage restorer utilizing a matrix converter and flywheel energy storage. IEEE Trans Ind Appl 45(1):222–231
Woodley NH, Morgan L, Sindaram A (1999) Experience with an inverter-based dynamic voltage restorer. IEEE Trans on Power Deliv 14(3):1181–1186
Yang XP, Zhang YX, Zhong YR (2008) Three-phase four-wire DSTATCOM based on a three-dimensional PWM algorithm. In: Electric utility deregulation and restructuring and power technologies, Nanijang, China, pp 2061–2066
Acknowledgments
The authors are thankful to Electrical Engineering Department, National Institute of Technology Jamshedpur, Jharkhand, 831014, India, for providing necessary infrastructure for successfully carrying out this investigation.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mani Sankar, M., Seksena, S.B.L. A cost effective voltage sag compensator for distribution system. Int J Syst Assur Eng Manag 8 (Suppl 1), 56–64 (2017). https://doi.org/10.1007/s13198-015-0373-3
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13198-015-0373-3