Skip to main content
Log in

Effect of an NSE PTA balloon in experimental lesion models

  • Original Article
  • Published:
Cardiovascular Intervention and Therapeutics Aims and scope Submit manuscript

Abstract

The effect of a scoring balloon has been reported. However, it is difficult to compare the effect of conventional vs. scoring balloons on the same lesion. Therefore, we assessed the scoring effect of the NSE with and without elements. The endpoints of this study were scoring grade in the eccentric agar model and crack incidence in the eccentric plaster model after ballooning. The scoring grade consisted of 5 levels: (1) almost none, (2) only at the surface, (3) cleavage in the depth of less than two-thirds, (4) cleavage in the depth of two-thirds or more, and (5) collapse. The scoring grade was assessed by blinded reviewers. To estimate the incidence of crack after ballooning for plaster model, balloon expansion pressure was recorded when plaster was broken. In the eccentric agar model, the overall scoring grade was significantly higher in the NSE group compared with the NSE without elements group (p = 0.002). The scoring grade at a diameter of 4.0 mm was significantly higher in the NSE group (p = 0.018). The scoring grade at nominal pressure was significantly higher in the NSE group (p = 0.016). In the eccentric plaster model, the crack incidence of the calcified region was overall significantly higher in the NSE group than that in the NSE without elements group (63 vs. 42 %, p = 0.04). A crack was found at calcification severity ≥180° in the NSE group (84 vs. 56 %, p = 0.014). Our result suggested that NSE exhibited a higher scoring effect in both models compared with conventional balloons.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Scheinert D, Peeters P, Bosiers M, et al. Results of the multicenter first-in-man study of a novel scoring balloon catheter for the treatment of infra-popliteal peripheral arterial disease. Catheter Cardiovasc Interv. 2007;70:1034–9.

    Article  PubMed  Google Scholar 

  2. Amighi J, Schillinger M, Dick P, et al. De novo superficial femoropopliteal artery lesions: peripheral cutting balloon angioplasty and restenosis rates—randomized controlled trial. Radiology. 2008;247:267–72.

    Article  PubMed  Google Scholar 

  3. Dick P, Sabeti S, Mlekusch W, et al. Conventional balloon angioplasty versus peripheral cutting balloon angioplasty for treatment of femoropopliteal artery in-stent restenosis: initial experience. Radiology. 2008;248:297–302.

    Article  PubMed  Google Scholar 

  4. Basile A, Tsetis D, Chlouverakis G, et al. Treatment of anastomotic stenoses of peripheral bypass grafts with cutting balloon angioplasty. Radiol Med. 2008;113:719–26.

    Article  CAS  PubMed  Google Scholar 

  5. Ashida K, Hayase T, Shinmura T. Efficacy of lacrosse NSE using the “leopard-crawl” technique on severely calcified lesions. J Invasive Cardiol. 2013;25:555–64.

    PubMed  Google Scholar 

  6. Barath P, Fishbein MC, Vari S, Forrester JS. Cutting balloon: a novel approach to percutaneous angioplasty. Am J Cardiol. 1991;68:1249–52.

    Article  CAS  PubMed  Google Scholar 

  7. Kawaguchi K, Kondo T, Shumiya T, Uchikawa T, Suzuki T, Awaji Y, Mochizuki M. Reduction of early elastic recoil by cutting balloon angioplasty as compared to conventional balloon angioplasty. J Invasive Cardiol. 2002;14:515–9.

    PubMed  Google Scholar 

  8. Soga Y, Takahara M, Iida O, et al. Relationship between primary patency and lesion length following bare nitinol stent placement for femoropopliteal disease. J Endovasc Ther. 2015;22:862–7.

    Article  PubMed  Google Scholar 

  9. Soga Y, Iida O, Hirano K, et al. Utility of new classification based on clinical and lesional factors after self-expandable nitinol stenting in the superficial femoral artery. J Vasc Surg. 2011;54:1058–66.

    Article  PubMed  Google Scholar 

  10. Iida O, Takahara M, Soga Y, et al. 1-Year results of the ZEPHYR Registry (Zilver PTX for the femoral artery and proximal popliteal artery): predictors of restenosis. JACC Cardiovasc Interv. 2015;8:1105–12.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoshimitsu Soga.

Ethics declarations

Conflict of interest

None of the authors has a real or perceived conflict of interest regarding the work presented in this manuscript.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Soga, Y., Ando, K. Effect of an NSE PTA balloon in experimental lesion models. Cardiovasc Interv and Ther 33, 35–39 (2018). https://doi.org/10.1007/s12928-016-0430-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12928-016-0430-0

Keywords

Navigation