The patient was a 91-year-old woman presenting with severe aortic valve stenosis. Pre-procedural computed tomography scan revealed a 45-mm abdominal aortic aneurysm (AAA). Transfemoral transcatheter aortic valve implantation (TF-TAVI) was performed after endovascular aortic repair (EVAR) of the AAA. The 23-mm Edwards Sapien XT system passed through the aortic stent graft smoothly. This is the first case report showing that successful TF-TAVI can be performed through a prior abdominal aortic stent graft. TF-TAVI after EVAR of AAA is a feasible option for patients with extremely poor access.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, et al. Thirty-day results of the sapien aortic bioprosthesis european outcome (source) registry: a european registry of transcatheter aortic valve implantation using the edwards sapien valve. Circulation. 2010;122:62–9.

    Article  PubMed  Google Scholar 

  2. Eltchaninoff H, Prat A, Gilard M, Leguerrier A, Blanchard D, Fournial G, et al. Transcatheter aortic valve implantation: early results of the france (french aortic national corevalve and edwards) registry. Eur Heart J. 2011;32:191–7.

    Article  PubMed  Google Scholar 

  3. Moat NE, Ludman P, de Belder MA, Bridgewater B, Cunningham AD, Young CP, et al. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the u.K. Tavi (united kingdom transcatheter aortic valve implantation) registry. J Am Coll Cardiol. 2011;58:2130–8.

    Article  PubMed  Google Scholar 

  4. Reinthaler M, Stahli BE, Gopalamurugan AB, Xiu PY, Aggarwal SK, Frohlich G, et al. Post-procedural arterial hypertension: implications for clinical outcome after transcatheter aortic valve implantation. J Heart Valve Dis. 2014;23:675–82.

    PubMed  Google Scholar 

  5. Brewster DC, Cronenwett JL, Hallett JW Jr, Johnston KW, Krupski WC, Matsumura JS. Guidelines for the treatment of abdominal aortic aneurysms. Report of a subcommittee of the joint council of the american association for vascular surgery and society for vascular surgery. J Vasc Surg. 2003;37:1106–17.

    Article  PubMed  Google Scholar 

  6. Drury-Smith M, Garnham A, Khogali S. Critical aortic stenosis in a patient with a large saccular abdominal aortic aneurysm: simultaneous transcatheter aortic valve implantation and drive-by endovascular aortic aneurysm repair. Catheter Cardiovasc Interv. 2012;80:1014–8.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hideyuki Kawashima.

Ethics declarations

Conflict of interest

Yusuke Watanabe is proctor for Transfemoral TAVI for Edwards Company. None of the other authors have disclosures to declare.

Research involving human participants and/or animals

This case report is involving human participants.

Informed consent

This patient agreed to participate in this case report, and written informed consent was obtained from this patient.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kawashima, H., Watanabe, Y. & Kozuma, K. Successful transfemoral aortic valve implantation through aortic stent graft after endovascular repair of abdominal aortic aneurysm. Cardiovasc Interv and Ther 32, 165–169 (2017). https://doi.org/10.1007/s12928-016-0385-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12928-016-0385-1

Keywords

Navigation