Abstract
The negative interference by bilirubin in serum creatinine estimation by Jaffe’s kinetic method is well known. Several approaches have been suggested to overcome this interference. In this article three different creatinine kits (Jaffe’s kinetic method) have been tested for bilirubin interference and its rectification using two simple approaches. The performance of three kits (A, B and C) supplied by three different manufacturers was tested using IQC and EQAS sera and pooled serum with added bilirubin. To overcome the bilirubin interference two approaches viz. NaOH preincubation and TCA precipitation were used. Bilirubin did interfere in creatinine estimation after a certain level (2.3 mg/dl). However, both NaOH preincubation and TCA precipitation approach rectified this interference. The performance of kit A was better than kit B and C. All the three kits showed bilirubin interference upon increasing the bilirubin concentration but kit A performed better than kit B and C. However, NaOH incubation and TCA precipitation methods overcame this interference to a great extent.
References
Weber JA, van Zanten AP. Interference in current methods for measurements of creatinine. Clin Chem. 1991;37:695–700.
Knapp ML, Hadid O. Investigations into negative interference by jaundiced plasma in kinetic Jaffe methods for plasma creatinine determination. Ann Clin Biochem. 1987;24:85–97.
Daugherty NA, Hammond KB, Osberg IM. Bilirubin interference with the kinetic Jaffe method for serum creatinine. Clin Chem. 1978;24:392–3.
Bowers LD, Wong ET. Kinetic serum creatinine assays: II. A critical evaluation and review. Clin Chem. 1980;26:555–61.
O’Leary N, Pembroke A, Duggan PF. A simplified procedure for eliminating the negative interference of bilirubin in the Jaffe reaction for creatinine. Clin Chem. 1992;38:1749–51.
Lolekha PH, Sritong N. Comparison of techniques for minimizing interference of bilirubin on serum creatinine determined by the kinetic Jaffe reation. J Clin Lab Anal. 1994;8:391–9.
Boot S, LaRoche N, Legg EF. Elimination of bilirubin interference in creatinine assays by routine technique: comparisons with a high performance liquid chromatography method. Ann Clin Biochem. 1994;31:262–6.
Lolekha PH, Jaruthunyaluck S, Srisawasdi P. Deproteinization of serum: another best approach to eliminate all forms of bilirubin interference on serum creatinine by kinetic Jaffe reaction. J Clin Lab Anal. 2001;15:116–21.
Srisawasdi P, Chaichanajarernkul U, Teerakanjana N, Vanavanan S, Kroll MH. Exogenous interference with Jaffe creatinine assays: addition of sodium do decyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe method. J Clin Lab Anal. 2010;24:123–33.
Vaishya R, Arora S, Singh B, Mallika U. Modification of Jaffe’s kinetic method decreases bilirubin interference: a preliminary report. Ind J Clin Biochem. 2010;25:64–6.
Fleming JJ. Analytical interference. Who should assess kits? Ind J Clin Biochem. 2015;30:245–6.
Greenberg N, Robert WL, Bachmann LM, Wright EC, Dalton RN, Zakowski JJ, Miller WG. Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles. Clin Chem. 2012;58:391–401.
Peake M, Whiting M. Measurement of serum creatinine—current status and future goals. Clin Biochem Rev. 2006;27:173–84.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
None.
Ethical Approval
Not required as this study does not contain any studies with human participants or animals performed by the author.
Rights and permissions
About this article
Cite this article
Nigam, P.K. Bilirubin Interference in Serum Creatinine Estimation by Jaffe’s kinetic Method and Its Rectification in Three Different Kits. Ind J Clin Biochem 31, 237–239 (2016). https://doi.org/10.1007/s12291-015-0545-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12291-015-0545-6