Skip to main content
Log in

The effectiveness of phase change materials in relation to summer thermal comfort in air-conditioned office buildings

  • Research Article
  • Building Thermal, Lighting, and Acoustics Modeling
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

The incorporation of Phase Change Materials (PCMs) into the opaque envelope of lightweight buildings is a good solution to compensate for the small thermal inertia, which usually entails pronounced overheating and high space cooling load in summer. However, the position and the thickness of the PCMs, as well as their thermal properties, must be attentively selected in order to ensure their effective operation. This paper shows a comprehensive investigation about the effectiveness of a commercial PCM, available in the form of mats, when installed within drywall partition systems in air-conditioned lightweight office buildings. The study is based on dynamic simulations carried out with EnergyPlus on a typical office building, with the aim to calculate the indoor operative temperature and the cooling load under thermostatic control. The performance for the base case (without PCM) is then compared with the case where PCM mats with various thickness and melting temperature are applied. The analysis is repeated in three different locations, ranging from Southern Europe (Rome, Italy), Continental Europe (Wien, Austria) and Northern Europe (London, UK). The results of the simulations highlight that in lightweight air-conditioned office buildings PCMs contribute to attenuate the inside surface temperature peak by around 0.5 °C, while also reducing the peak cooling load by 10% or even 15%, depending on the PCM thickness and on the outdoor climate. The conclusions may help designers to make the correct choices in terms of thickness of the PCMs, scheduled rate of nighttime ventilation and value of the peak melting temperature.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Alam M, Jamil H, Sanjayan J, Wilson J (2014). Energy saving potential of phase change materials in major Australian cities. Energy and Buildings, 78: 192–201.

    Article  Google Scholar 

  • Ascione F, Bianco N, De Masi RF, de’ Rossi F, Vanoli GP (2014). Energy refurbishment of existing buildings through the use of phase change materials: Energy savings and indoor comfort in the cooling season. Applied Energy, 113: 990–1007.

    Article  Google Scholar 

  • ASHRAE (2009). ASHRAE Handbook: Fundamentals. Atlanta, GA, USA: American Society of Heating, Refrigerating and Air- Conditioning Engineers.

  • Auzeby M, Wei S, Underwood C, Tindall J, Chen C, Ling H, Buswell R (2016). Effectiveness of using phase change materials on reducing summer overheating issues in UK residential buildings with identification of influential factors. Energies, 9: 605.

    Article  Google Scholar 

  • Berardi U, Soudian S (2018). Benefits of latent thermal energy storage in the retrofit of Canadian high-rise residential buildings. Building Simulation, 11: 709–723.

    Article  Google Scholar 

  • Castell A, Farid MM (2014). Experimental validation of a methodology to assess PCM effectiveness in cooling building envelopes passively. Energy and Buildings, 81: 59–71.

    Article  Google Scholar 

  • Delcroix B, Kummert M, Daoud A, Bouchard J (2015). Influence of experimental conditions on measured thermal properties used to model phase change materials. Building Simulation, 8: 637–650.

    Article  Google Scholar 

  • Dermardiros V, Chen Y, Athienitis AK (2015). Modelling of an active PCM thermal energy storage for control applications. Energy Procedia, 78: 1690–1695.

    Article  Google Scholar 

  • Evola G, Marletta L, Sicurella F (2013). A methodology for investigating the effectiveness of PCM wallboards for summer thermal comfort in buildings. Building and Environment, 59: 517–527.

    Article  Google Scholar 

  • Evola G, Marletta L (2014). The effectiveness of PCM wallboards for the energy refurbishment of lightweight buildings. Energy Procedia, 62: 13–21.

    Article  Google Scholar 

  • Evola G, Marletta L, Sicurella F (2014). Simulation of a ventilated cavity to enhance the effectiveness of PCM wallboards for summer thermal comfort in buildings. Energy and Buildings, 70: 480–489.

    Article  Google Scholar 

  • Guarino F, Athienitis A, Cellura M, Bastien D (2017). PCM thermal storage design in buildings: Experimental studies and applications to solaria in cold climates. Applied Energy, 185: 95–106.

    Article  Google Scholar 

  • iNSPiRe (2017). iNSPiRe Project reports D21-D21c Survey on the Energy Needs and Architectural Features of the EU Building Stock 2014. Available at https://doi.org/www.inspirefp7eu/about-inspire/downloadable-reports. Accessed Dec 2017.

  • ISO (2005). ISO Standard 7730. Ergonomics of the thermal environment—Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. Geneva: International Organization for Standardization.

  • Jamil H, Alam M, Sanjayan J, Wilson J (2016). Investigation of PCM as retrofitting option to enhance occupant thermal comfort in a modern residential building. Energy and Buildings, 133: 217–229.

    Article  Google Scholar 

  • Kalnæs SE, Jelle BP (2015). Phase change materials and products for building applications: A state-of-the-art review and future research opportunities. Energy and Buildings, 94: 150–176.

    Article  Google Scholar 

  • Kenisarin M, Mahkamov K (2016). Passive thermal control in residential buildings using phase change materials. Renewable and Sustainable Energy Reviews, 55: 371–398.

    Article  Google Scholar 

  • Kosny J, Shrestha SS, Stovall TK, Yarbrough DW (2010). Theoretical and experimental thermal performance analysis of complex thermal storage membrane containing bio-based phase-change material (PCM). In: Proceedings of XI International conference on thermal performance of the exterior envelopes of whole buildings, Clearwater Beach, FL, USA.

    Google Scholar 

  • Kottek M, Grieser J, Beck C, Rudolf B, Rubel F (2006). World Map of the Köppen-Geiger climate classification updated. Meteorologische Zeitschrift, 15: 259–263.

    Article  Google Scholar 

  • Kuznik F, Virgone J, Roux J-J (2008). Energetic efficiency of room wall containing PCM wallboard: A full-scale experimental investigation. Energy and Buildings, 40: 148–156.

    Article  Google Scholar 

  • Kuznik F, Virgone J (2009). Experimental assessment of a phase change material for wall building use. Applied Energy, 86: 2038–2046.

    Article  Google Scholar 

  • Lee KO, Medina M A, Raith E, Sun X (2015). Assessing the integration of a thin phase change material (PCM) layer in a residential building wall for heat transfer reduction and management. Applied Energy, 137: 699–706.

    Article  Google Scholar 

  • Lei J, Yang J, Yang E-H (2016). Energy performance of building envelopes integrated with phase change materials for cooling load reduction in tropical Singapore. Applied Energy, 162: 207–217.

    Article  Google Scholar 

  • Moreles E, Huelsz G, Barrios G (2018). Hysteresis effects on the thermal performance of building envelope PCM-walls. Building Simulation, 11: 519–531.

    Article  Google Scholar 

  • Muruganantham K, Phelan P, Horwath P, Ludlam D, Mc Donald T (2010). Experimental investigation of a bio phase-change material to improve building energy performance. In: Proceedings of ASME2010 4th International Conference on Energy Sustainability ES2010, Phoenix, AZ, USA.

    Google Scholar 

  • Nicol JF, Humphreys MA (2002). Adaptive thermal comfort and sustainable thermal standards for buildings. Energy and Buildings, 34: 563–572.

    Article  Google Scholar 

  • Nikoofard S, Ugursal VI, Beausoleil-Morrison I (2015). Techno-economic assessment of the impact of phase change material thermal storage on the energy consumption and GHG emissions of the Canadian Housing Stock. Building Simulation, 8: 225–238.

    Article  Google Scholar 

  • Pomianowski M, Heiselberg P, Zhang Y (2013). Review of thermal energy storage technologies based on PCM application in buildings. Energy and Buildings, 67: 56–69.

    Article  Google Scholar 

  • Ramakrishnan S, Wang X, Sanjayan J, Wilson J (2017). Thermal performance of buildings integrated with phase change materials to reduce heat stress risks during extreme heatwave events. Applied Energy, 194: 410–421.

    Article  Google Scholar 

  • Roman KK, O’Brien T, Alvey JB, Woo O (2016). Simulating the effects of cool roof and PCM (phase change materials) based roof to mitigate UHI (urban heat island) in prominent US cities. Energy, 96: 103–117.

    Article  Google Scholar 

  • Saffari M, de Gracia A, Fernández C, Cabeza LF (2017a). Simulationbased optimization of PCM melting temperature to improve the energy performance in buildings. Applied Energy, 202: 420–434.

    Article  Google Scholar 

  • Saffari M, de Gracia A, Ushak S, Cabeza LF (2017b). Passive cooling of buildings with phase change materials using whole-building energy simulation tools: A review. Renewable and Sustainable Energy Reviews, 80: 1239–1255.

    Article  Google Scholar 

  • Sage-Lauck JS, Sailor DJ (2014). Evaluation of phase change materials for improving thermal comfort in a super-insulated residential building. Energy and Buildings, 79: 32–40.

    Article  Google Scholar 

  • Seong Y B, Lim J H (2013). Energy saving potentials of phase change materials applied to lightweight building envelopes. Energies, 6: 5219–5230.

    Article  Google Scholar 

  • Shrestha S, Miller W, Stovall T, Desjarlais A, Childs K, Porter W, Bhandari M, Coley S (2011). Modeling PCM-enhanced insulation system and benchmarking EnergyPlus against controlled field data. In: Proceedings of the 12th IBPSA International Building Simulation Conference, Sydney, Australia.

    Google Scholar 

  • Sicurella F, Evola G, Wurtz E (2012). A statistical approach for the evaluation of thermal and visual comfort in free-running buildings. Energy and Buildings, 47: 402–410.

    Article  Google Scholar 

  • Soares N, Reinhart CF, Hajiah A (2017). Simulation-based analysis of the use of PCM-wallboards to reduce cooling energy demand and peak-loads in low-rise residential heavyweight buildings in Kuwait. Building Simulation, 10: 481–495.

    Article  Google Scholar 

  • Souayfane F, Fardoun F, Biwole PH (2016). Phase change materials (PCM) for cooling applications in buildings: A review. Energy and Buildings, 129: 396–431.

    Article  Google Scholar 

  • Sun X, Zhang Q, Medina M A, Lee K O (2014). Energy and economic analysis of a building enclosure outfitted with a phase change material board (PCMB). Energy Conversion and Management, 83: 73–78.

    Article  Google Scholar 

  • Tabares-Velasco PC, Christensen C, Bianchi M (2012). Verification and validation of EnergyPlus phase change material model for opaque wall assemblies. Building and Environment, 54: 186–196.

    Article  Google Scholar 

  • Underwood CP, Yik FWH (2004). Modelling Methods for Energy in Buildings. Oxford, UK: Blackwell Publishing.

    Book  Google Scholar 

  • US Department of Energy (2017). EnergyPlus version 8.8. Available at https://doi.org/energyplus.net.

  • Vautherot M, Maréchal F, Farid MM (2015). Analysis of energy requirements versus comfort levels for the integration of phase change materials in buildings. Journal of Building Engineering, 1: 53–62.

    Article  Google Scholar 

  • Voelker C, Kornadt O, Ostry M (2008). Temperature reduction due to the application of phase change materials. Energy and Buildings, 40: 937–944.

    Article  Google Scholar 

  • Wang X, Yu H, Li L, Zhao M (2016). Experimental assessment on the use of phase change materials (PCMs)-bricks in the exterior wall of a full-scale room. Energy Conversion and Management, 120: 81–89.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Gianpiero Evola.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Costanzo, V., Evola, G., Marletta, L. et al. The effectiveness of phase change materials in relation to summer thermal comfort in air-conditioned office buildings. Build. Simul. 11, 1145–1161 (2018). https://doi.org/10.1007/s12273-018-0468-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-018-0468-2

Keywords

Navigation