Application of artificial neural network and genetic algorithm to the optimization of load distribution for a multiple-type-chiller plant

  • Research Article
  • Building Systems and Components
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Numerous methods are available in various studies that investigate the optimization of central air conditioning systems. However, the majority of these studies focus on a single chiller or multiple chillers of identical capacity and type. Although the data indicated substantial energy conservation, all relevant findings were optimized under continuous concave functions, which cannot resolve the optimal load distributions of multiple-chiller plants commonly seen today due to their discontinuous properties. This study targets a large public exhibition venue, which uses a central air conditioning system consisting of heterogeneous chillers: fixed /variable frequency screw chillers, and centrifugal chillers. This system adopts a manual method (MM) for controlling the on/off operation of chillers; after an extended period of monitoring and collecting data, the operational characteristics of each chiller are better understood. This study uses the neural network (NN) to establish a chiller power consumption model, which considers the operating constrains of various types of chillers to ensure stable operation of the chiller plant. Genetic algorithm (GA) is also integrated while satisfying cooling load conditions to optimize chiller loading and determine the minimum power consumption of chiller plant. This is achieved by overcoming the deficiency of the traditional method, which fails to converge at low loads, and liberating from the restrictions limited by discontinuous functions. The results show that integrating NN and GA (NNGA) between 95% and 55% cooling loads improved power savings compared to MM load distributions, saving total power consumption by approximately 14.55%. A simulation data analysis for a one-year operation period showed that the proposed method can save up to 16.68% in power consumption over the MM method on a monthly basis and is conclusively superior to the MM controlled chiller model. This proved that the NNGA method proposed in this study provides an effective solution for optimizing load distributions of common multiple-chiller plants in parallel operation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • ASHRAE (2000). ASHRAE Handbook—HVAC Systems and Equipment. Atlanta, GA, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • Braun JE (1988). Methodologies for the design and control of central of cooling plants. PhD Thesis, University of Wisconsin, USA.

    Google Scholar 

  • Chang Y-C (2005a). Genetic algorithm based optimal chiller loading for energy conservation. Applied Thermal Engineering, 25: 2800–2815.

    Article  Google Scholar 

  • Chang Y-C (2005b). Verification for the promotion of chiller performance audits. Journal of Refrigeration and Air Conditioning Professional Engineer, 1(2): 61–67. (in Chinese)

    Google Scholar 

  • Chang Y-C (2006). An outstanding method for saving energy— Optimal chiller operation. IEEE Transactions on Energy Conversion, 21: 527–532.

    Article  Google Scholar 

  • Chang Y-C, Chan T-S, Lee W-S (2010). Economic dispatch of chiller plant by gradient method for saving energy. Applied Energy, 87: 1096–1101.

    Article  Google Scholar 

  • Chang Y-C, Lin J-K, Chuang M-H (2005). Optimal chiller loading by genetic algorithm for reducing energy consumption. Energy and Buildings, 37: 147–155.

    Article  Google Scholar 

  • Chao C-M, Liang S-F (2006). A parallel back-propagation algorithm with the Levenberg Marquardt method. Information Management, 8: 85–108.

    Google Scholar 

  • Chen C-L, Chang Y-C, Chan T-S (2014). Applying smart models for energy saving in optimal chiller loading. Energy and Buildings, 68: 364–371.

    Article  Google Scholar 

  • Chow TT, Zhang GQ, Lin Z, Song CL (2002). Global optimization of absorption chiller system by genetic algorithm and neural network. Energy and Buildings, 34: 103–109.

    Article  Google Scholar 

  • Dossat RJ (1991). Principles of Refrigeration. New York: John Wiley & Sons.

    Google Scholar 

  • Holland JH (1922). Genetic Algorithms. Scientific American, 267(1): 66–72.

    Article  Google Scholar 

  • Hu S-C, Chuah YK (2003). Power consumption of semiconductor fabs in Taiwan. Energy, 28: 895–907.

    Article  Google Scholar 

  • Levenberg K (1944). A method for the solution of certain non-linear problems in least squares. Quarterly of Applied Mathematics, 2: 164–168.

    Article  MathSciNet  MATH  Google Scholar 

  • Lu J-T, Chang Y-C, Ho C-Y (2015). The optimization of chiller loading by adaptive neuro-fuzzy inference system and genetic algorithms. Mathematical Problems in Engineering, Article ID 306401.

  • Marquardt DW (1963). An Algorithm for Least-Squares Estimation of Nonlinear Parameters. Journal of the Society for Industrial and Applied Mathematics, 11: 431–441.

    Article  MathSciNet  MATH  Google Scholar 

  • Rumelhart DE, McClelland JL, PDP Research Group (1986). Parallel Distributed Processing. Cambridge, MA, USA: MIT Press.

    Google Scholar 

  • Taiwan Bureau of Energy (2016). Energy Supply and Demand Situation of Taiwan in 2015. Energy Statistical Annual Reports. pp.1–7. Available at http://goo.gl/gnqIaX. Accessed 25 Aug 2016.

  • Yeh IC (1997). Application of Neural Network. Taipei: Ru-Lin Companies Inc.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tien-Shun Chan.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chan, TS., Chang, YC. & Huang, JH. Application of artificial neural network and genetic algorithm to the optimization of load distribution for a multiple-type-chiller plant. Build. Simul. 10, 711–722 (2017). https://doi.org/10.1007/s12273-017-0363-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-017-0363-2

Keywords

Navigation