Abstract
This paper investigates the role of impact in stilling basin design for the enhancement of energy dissipation in order to protect the downstream structures from excessive scouring. Large number of experiments (57 test runs) have been carried out for Froude numbers 3.85, 2.85 and 1.85 to evolve the new stilling basin model by employing the impact walls of different configurations for dissipation of energy of flowing water for pipe outlets. Performance of outlet basins having impact wall of varying size and location were evaluated based on dimensionless number called as Performance Index (PI), which is the ratio of grains Froude number to scour index. Higher values of PI indicate better performance of the basin. It is concluded that by placing the appropriate impact wall size at suitable location, not only the efficiency of basin increases but also the length of basin reduces by 30% as compared to USBR VI stilling basin.
Similar content being viewed by others
References
Bradley, J. N. and Peterka, A. J. (1957). “Hydraulic design of stilling basins.” Journal of A.S.C.E., Hydraulic Engg., Vol. 83, No. 5, pp. 1401–1406.
Garde, R. J., Saraf, P. D., and Dahigaonkar, D. J. (1986). “Evolution of design of energy dissipator for pipe outlets.” J. of Irrigation and Power, Vol. 42, No. 3, pp. 145–154.
Goel, A. (2007). “Experimental study on stilling basins for square outlets.” Proceeding 3rd International Conference on Applied and Theoretical Mechanics, Spain, pp. 14–16.
Goel, A. and Verma, D. V. S. (2001). “Model studies on stilling basins for pipe outlets.” J. of Irrigation and Drainage Systems, Kluwer Academic Publisher, the Netherlands, Vol. 15, No. 1, pp. 81–91.
Goel, A. and Verma, D. V. S. (2006). “Development of efficient stilling basins for pipe outlets.” ASCE Journal of Irrigation and Drainage Engineering, Vol. 13, No. 4, p. 194–200.
Goel, A. (2008). “Design of stilling basin for circular pipe outlet.” Canadian Journal of Civil Engineering, Vol. 35, No. 12, pp. 1365–1374.
Tiwari, H. L. (2012). Experimental Investigations of Hydraulic Energy Dissipators for Rectangular pipe outlets, PhD Thesis, MANIT Bhopal.
Tiwari, H. L. Goel, A., and Gahlot, V. K. (2011). “Evolution of stilling basin.” Proc. 38th National conference on Fluid Mechanics and Fluid power, Bhopal, India. pp. 1–8.
Verma, D. V. S. and Goel, A. (2000). “Stilling basins for outlets using wedge shaped splitter blocks.” ASCE Journal of Irrigation and Drainage Engineering, Vol. 126, No. 3, pp. 179–184.
Verma, D. V. S. and Goel, A. (2003). “Development of efficient stilling basins for pipe outlets.” ASCE Journal of Irrigation and Drainage Eng. Vol. 129, No. 3, pp. 194–200.
Vollmer, E. and Khader, M. H. A. (1971). “Counter current energy dissipator for conduit outlets.” International J. of Water Power, Vol. 13, No. 7, pp. 260–267.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tiwari, H.L., Goel, A. Effect of impact wall on energy dissipation in stilling basin. KSCE J Civ Eng 20, 463–467 (2016). https://doi.org/10.1007/s12205-015-0292-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12205-015-0292-5