Abstract

PET enables quantitative imaging of the rate constants K 1, k 2, k 3, and k 4, with a reversible two tissue compartment model (2TCM). A new method is proposed for computing all of these rates within a reasonable time, less than 1 min. A set of differential equations for the reversible 2TCM was converted into a single formula consisting of differential and convolution terms. The validity was tested on clinical data with 18F-FLT PET for patients with glioma (n = 39). Parametric images were generated with the formula that was developed. Parametric values were extracted from regions of interest (ROIs) for glioma from the images generated, and they were compared with those obtained with the non-linear fitting method. We performed simulation studies for testing accuracy by generating simulated images, assuming clinically expected ranges of the parametric values. The computation time was about 20 s, and the quality of the images generated was acceptable. The values obtained for K 1 for grade IV tumor were 0.24 ± 0.23 and 0.26 ± 0.25 ml−1 min−1 g−1 for the image-based and ROI-based methods, respectively. The values were 0.21 ± 0.12 and 0.21 ± 0.12 min−1 for k 2, 0.13 ± 0.07 and 0.13 ± 0.07 min−1 for k 3, and 0.052 ± 0.020 and 0.054 ± 0.021 min−1 for k 4. The differences between the methods were not significant. Regression analysis showed correlations of r = 0.94, 0.86, 0.71, and 0.52 for these parameters. Simulation demonstrated that the accuracy was within acceptable ranges, namely, the correlations were r = 0.99, r = 0.97, r = 0.99, and r = 0.91 for K 1, k 2, k 3, and k 4, respectively, between estimated and assumed values. This results suggest that parametric images can be obtained fully within reasonable time, accuracy, and quality.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Gunn RN, Gunn SR, Turkheimer FE, Aston JA, Cunningham VJ. Positron emission tomography compartmental models: a basis pursuit strategy for kinetic modeling. J Cereb Blood Flow Metab. 2002;22:1425–39.

    Article  CAS  PubMed  Google Scholar 

  2. Watabe H, Ikoma Y, Kimura Y, Naganawa M, Shidahara M. PET kinetic analysis—compartmental model. Ann Nucl Med. 2006;20:583–8.

    Article  CAS  PubMed  Google Scholar 

  3. Patlak C, Blasberg R. Graphical evaluation of blood-tobrain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab. 1985;5:584–90.

    Article  CAS  PubMed  Google Scholar 

  4. Logan J, Fowler J, Volkow N, Wolf A, Dewey S, Schlyer D, et al. Graphical analysis of reversible radioligand binding from time-activity measurements applied to N-[11C]methyl-(−)-cocaine PET studies in human subjects. J Cereb Blood Flow Metab. 1990;10(5):740–7.

    Article  CAS  PubMed  Google Scholar 

  5. Yokoi T, Iida H, Itoh H, Kanno I. A new graphic plot analysis for cerebral blood flow and partition coefficient with iodine-123-iodoamphetamine and dynamic SPECT validation studies using oxygen-15-water and PET. J Nucl Med. 1993;34(3):498–505.

    CAS  PubMed  Google Scholar 

  6. Ichise M, Toyama H, Innis R, Carson R. Strategies to improve neuroreceptor parameter estimation by linear regression analysis. J Cereb Blood Flow Metab. 2002;22:1271–81.

    Article  PubMed  Google Scholar 

  7. Slifstein M, Laruelle M. Effects of statistical noise on graphic analysis of PET neuroreceptor studies. J Nucl Med. 2000;41(12):2083–8.

    CAS  PubMed  Google Scholar 

  8. Hong YT, Fryer TD. Kinetic modelling using basis functions derived from two-tissue compartmental models with a plasma input function: general principle and application to [18F]fluorodeoxyglucose positron emission tomography. Neuroimage. 2010;51:164–72.

    Article  PubMed  Google Scholar 

  9. Schiepers C, Chen W, Dahlbom M, Cloughesy T, Hoh CK, Huang SC. 18F-fluorothymidine kinetics of malignant brain tumors. Eur J Nucl Med Mol Imaging. 2007;34:1003–11.

    Article  CAS  PubMed  Google Scholar 

  10. Muzi M, Mankoff DA, Grierson JR, Wells JM, Vesselle H, Krohn JM. Kinetic Modeling of 3′-deoxy-3′ fluorothymidine in somatic tumors: mathematical studies. J Nucl Med. 2005;46:371–80.

    CAS  PubMed  Google Scholar 

  11. Muzi M, Spence AM, O’Sullivan F, Mankoff DA, Wells JM, Grierson JR, Link JM, Krohn KA. Kinetic analysis of 3′-deoxy-3′ fluorothymidine in patients with gliomas. J Nucl Med. 2006;47:1612–21.

    CAS  PubMed  Google Scholar 

  12. Koeppe RA, Holden JE, Ip WR. Performance comparison of parameter estimation techniques for the quantitation of local cerebral blood flow by dynamic positron computed tomography. J Cereb Blood Flow Metab. 1985;5:224–34.

    Article  CAS  PubMed  Google Scholar 

  13. Gunn RN, Lammertsma AA, Hume SP, Cunningham VJ. Parametric imaging of ligand-receptor binding in PET using a simplified reference region model. Neuroimage. 1997;6:279–87.

    Article  CAS  PubMed  Google Scholar 

  14. Shinomiya A, Kawai N, Okada M, Miyake K, Nakamura T, Kushida Y, Haba R, Kudomi N, Yamamoto Y, Tokuda M, Tamiya T. Evaluation of 3′-deoxy-3′-[18F]-fluorothymidine (18F-FLT) kinetics correlated with thymidine kinase-1 expression and cell proliferation in newly diagnosed gliomas. Eur J Nucl Med Mol Imaging. 2013;40:175–85.

    Article  CAS  PubMed  Google Scholar 

  15. Watabe H, Jino H, Kawachi N, Teramoto N, Hayashi T, Ohta Y, Iida H. Parametric imaging of myocardial blood flow with 15O-water and PET using the basis function method. J Nucl Med. 2005;46:1219–24.

    PubMed  Google Scholar 

  16. Boellaard R, Knaapen P, Rijbroek A, Luurtsema GJ, Lammertsma AA. Evaluation of basis function and linear least squares methods for generating parametric blood flow images using 15O-water and positron emission tomography. Mol Imaging Biol. 2005;7:273–85.

    Article  PubMed  Google Scholar 

  17. Kudomi N, Hirano Y, Koshino K, Hayashi T, Watabe H, Fukushima K, Moriwaki H, Teramoto N, Iihara K, Iida H. Rapid quantitative CBF and CMRO2 measurements from a single PET scan with sequential administration of dual 15O-labeled tracers. J Cereb Blood Flow Metab. 2013;33:440–8.

    Article  CAS  PubMed  Google Scholar 

  18. Kimura Y, Senda M, Alpert NM. Fast formation of statistically reliable FDG parametric images based on clustering and principal components. Phys Med Biol. 2002;47:455–68.

    Article  CAS  PubMed  Google Scholar 

  19. Breier A, Su T, Saunders R, Carson R, Kolachana B, de Bartolomeis A, et al. Schizophrenia is associated with elevated amphetamine-induced synaptic dopamine concentrations: evidence from a novel positron emission tomography method. Proc Natl Acad Sci USA. 1997;94:2569–74.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  20. Endres C, Kolachana B, Saunders R, Su T, Weinberger D, Breier A, et al. Kinetic modeling of [11C]raclopride: combined PET-microdialysis studies. J Cereb Blood Flow Metab. 1997;17:932–42.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors thank Dr. Akihiro Nishiyama for helping us in developing and checking the formula in this study, and the staff of the Department of Radiology, Kagawa University Hospital. This study by NK, YY, and YN was supported by the Ministry of Education, Science, Sports and Culture of Japan, a grant-in-aid for JSPS KAKENHI (C) (Grant Number 26460728 2014–2016).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nobuyuki Kudomi.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (DOC 1500 kb)

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kudomi, N., Maeda, Y., Hatakeyama, T. et al. Fully parametric imaging with reversible tracer 18F-FLT within a reasonable time. Radiol Phys Technol 10, 41–48 (2017). https://doi.org/10.1007/s12194-016-0367-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12194-016-0367-0

Keywords

Navigation