Development of an image operation system with a motion sensor in dental radiology

  • Published:
Radiological Physics and Technology Aims and scope Submit manuscript

Abstract

During examinations and/or treatment, a dentist in the examination room needs to view images with a proper display system. However, they cannot operate the image display system by hands, because dentists always wear gloves to be kept their hands away from unsanitized materials. Therefore, we developed a new image operating system that uses a motion sensor. We used the Leap motion sensor technique to read the hand movements of a dentist. We programmed the system using C++ to enable various movements of the display system, i.e., click, double click, drag, and drop. Thus, dentists with their gloves on in the examination room can control dental and panoramic images on the image display system intuitively and quickly with movement of their hands only. We investigated the time required with the conventional method using a mouse and with the new method using the finger operation. The average operation time with the finger method was significantly shorter than that with the mouse method. This motion sensor method, with appropriate training for finger movements, can provide a better operating performance than the conventional mouse method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Leap motion. https://www.leapmotion.com/product.

  2. Ogura T, Sato M, Ishida Y, Hayashi N. Doi K Development of a novel method for manipulation of angiographic images by use of a motion sensor in operating rooms. Radiol Phys Technol. 2014;7(2):228–34.

    Article  PubMed  Google Scholar 

  3. Weichert Frank, Bachmann Daniel, Rudak Bartholomäus, Fisseler Denis. Analysis of the accuracy and robustness of the leap motion controller. Sensors. 2013;13(5):6380–93.

    Article  PubMed Central  PubMed  Google Scholar 

  4. Leap motion developer portal C++ SDK Documentation. https://developer.leapmotion.com/documentation/skeletal/cpp/index.html.

Download references

Acknowledgments

The authors wish to thank Daiki Ito, Daisuke Nagahama, Tomoya Kitaoka, Keisuke Kimura, Rumi Tyo, Ayaka Sato, Syoko Tsutsumi, Shiori Oue, Ayaka Nakamura, Ryosuke Miki, Mika Okajima, and Kiyoshi Isobe of the Gunma Prefectural College of Health Sciences for their helpful assistance in the measurements.

Conflict of interest

The authors declare that they have no conflict of interest for this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mitsuru Sato.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sato, M., Ogura, T., Yasumoto, Y. et al. Development of an image operation system with a motion sensor in dental radiology. Radiol Phys Technol 8, 243–247 (2015). https://doi.org/10.1007/s12194-015-0313-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12194-015-0313-6

Keywords

Navigation