Abstract
Surgical implants are essential elements of repair procedures to correct worn out joints, damaged spinal components, heart and vascular disease, and chronic pain. However, many of the materials that provide stability, flexibility, and durability to the implants are also immunogenic. Fortunately, allergic responses to surgical implants are infrequent. When they do occur, however, the associated pain, swelling, inflammation, and decreased range of motion can significantly impair the implant function. Given the high numbers of joint replacements performed in the developed world, allergic reactions to orthopedic implants form the largest category of allergic responses. The most important allergens in this category include nickel, cobalt, chromium, and bone cement. These allergens are also the most important in reactions to spinal surgeries. Multiple cardiac and neurostimulatory devices are constructed of metals and adhesives that can be sensitizing in some individuals. Implantable pulse generators, important in cardiac pacemakers, gastric stimulators, and neurostimulators, may include components made of stainless steel, titanium alloy, platinum and iridium, epoxy resins, poly methyl methacrylates, and isocyanates, all of which are immunogenic in some patients. Cardiac stents and patches are often made of Nitinol, a composite of nickel and titanium. More surgical procedures are closed using skin glues, which are also capable of triggering a blistering contact dermatitis. Patch testing is the gold standard to determine sensitization, and this review provides a list of standard allergens to test for different implants. The patients most appropriate for testing include (1) pre-operative joint replacement patients with a prior history of skin reactions to metal jewelry, jean snaps, watch bands, metal glass frames, artificial nails, or skin glue; (2) post-operative joint replacement failure patients needing revision without an obvious cause such as infection or mechanical incompatibility; and (3) post-operative cardiac or neurological patients with localized rash, pain, swelling, or inflammation near or over the implant.
Similar content being viewed by others
References
Cram P, Lu X, Kaboli PJ et al (2011) Clinical characteristics and outcomes of Medicare patients undergoing total hip arthroplasty, 1991–2008. JAMA 305:1560–1567
Cram P, Lu X, Kates SL, Singh JA, Li Y, Wolf BR (2012) Total knee arthroplasty volume, utilization, and outcomes among Medicare beneficiaries, 1991–2010. JAMA 308:1227–1236
Maradit Kremers H, Larson DR, Crowson CS et al (2015) Prevalence of total hip and knee replacement in the United States. J Bone Joint Surg Am 97:1386–1397
Ibrahim SA, Kim H, McConnell KJ (2016) The CMS comprehensive care model and racial disparity in joint replacement. JAMA 316:1258–1259
Hawker GA, Badley EM, Croxford R et al (2009) A population-based nested case-control study of the costs of hip and knee replacement surgery. Med Care 47:732–741
Rasanen P, Paavolainen P, Sintonen H et al (2007) Effectiveness of hip or knee replacement surgery in terms of quality-adjusted life years and costs. Acta Orthop 78:108–115
Daigle ME, Weinstein AM, Katz JN, Losina E (2012) The cost-effectiveness of total joint arthroplasty: a systematic review of published literature. Best Pract Res Clin Rheumatol 26:649–658
Nwachukwu BU, Bozic KJ, Schairer WW et al (2015) Current status of cost utility analyses in total joint arthroplasty: a systematic review. Clin Orthop Relat Res 473:1815–1827
AAOS (2017) American Academy of Orthopaedic Surgeons (AAOS) to launch family of orthopaedic registries. http://newsroom.aaos.org/media-resources/news/american-academy-of-orthopaedic-surgeons-aaos-to-launch-family-of-orthopaedic-registries.htm#/search/aaos18/contact_type_id/14763690. Accessed 01/22/2018.
Ong KL, Mowat FS, Chan N, Lau E, Halpern MT, Kurtz SM (2006) Economic burden of revision hip and knee arthroplasty in Medicare enrollees. Clin Orthop Relat Res 446:22–28
Labek G, Thaler M, Janda W, Agreiter M, Stockl B (2011) Revision rates after total joint replacement: cumulative results from worldwide joint register datasets. J Bone Joint Surg (Br) 93:293–297
Labek G, Todorov S, Iovanescu L, Stoica CI, Bohler N (2013) Outcome after total ankle arthroplasty-results and findings from worldwide arthroplasty registers. Int Orthop 37:1677–1682
Dummit LA, Kahvecioglu D, Marrufo G et al (2016) Association between hospital participation in a Medicare bundled payment initiative and payments and quality outcomes for lower extremity joint replacement episodes. JAMA 316:1267–1278
Sharkey PF, Lichstein PM, Shen C, Tokarski AT, Parvizi J (2014) Why are total knee arthroplasties failing today—has anything changed after 10 years? J Arthroplast 29:1774–1778
Jafari SM, Coyle C, Mortazavi SM, Sharkey PF, Parvizi J (2010) Revision hip arthroplasty: infection is the most common cause of failure. Clin Orthop Relat Res 468:2046–2051
Delaunay C, Hamadouche M, Girard J, Duhamel A (2013) So FG. What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res 471:3863–3869
Evans EM, Freeman MA, Miller AJ, Vernon-Roberts B (1974) Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement. J Bone Joint Surg (Br) 56-B:626–642
Elves MW, Wilson JN, Scales JT, Kemp HB (1975) Incidence of metal sensitivity in patients with total joint replacements. Br Med J 4:376–378
Thienpont E, Berger Y (2013) No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature. Knee Surg Sports Traumatol Arthrosc 21:636–640
Granchi D, Cenni E, Trisolino G, Giunti A, Baldini N (2005) Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater 77:257–264
Krecisz B, Kiec-Swierczynska M, Chomiczewska-Skora D (2012) Allergy to orthopedic metal implants—a prospective study. Int J Occup Med Environ Health 25:463–469
Eben R, Dietrich KA, Nerz C et al (2010) Contact allergy to metals and bone cement components in patients with intolerance of arthroplasty. Dtsch Med Wochenschr 135:1418–1422
Atanaskova Mesinkovska N, Tellez A, Molina L et al (2012) The effect of patch testing on surgical practices and outcomes in orthopedic patients with metal implants. Arch Dermatol 148:687–693
Thomas P, Braathen LR, Dorig M et al (2009) Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation. Allergy 64:1157–1165
Treudler R, Simon JC (2007) Benzoyl peroxide: is it a relevant bone cement allergen in patients with orthopaedic implants? Contact Dermatitis 57:177–180
Edwards SA, Gardiner J (2007) Hypersensitivity to benzoyl peroxide in a cemented total knee arthroplasty: cement allergy. J Arthroplast 22:1226–1228
Bircher A, Friederich NF, Seelig W, Scherer K (2012) Allergic complications from orthopaedic joint implants: the role of delayed hypersensitivity to benzoyl peroxide in bone cement. Contact Dermatitis 66:20–26
Haddad FS, Cobb AG, Bentley G, Levell NJ, Dowd PM (1996) Hypersensitivity in aseptic loosening of total hip replacements. The role of constituents of bone cement. J Bone Joint Surg (Br) 78:546–549
Erpenbach J, Hofmeister E (2008) Hypersensitivity to polymethylmethacrylate following shoulder hemiarthroplasty. Orthopedics 31:708
Anand A, McGlynn F, Jiranek W (2009) Metal hypersensitivity: can it mimic infection? J Arthroplast 24:826 e825–826 e828
Willert HG, Buchhorn GH, Fayyazi A et al (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87:28–36
Thomas P, von der Helm C, Schopf C et al (2015) Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology, and peri-implant cytokine expression pattern. Biomed Res Int 2015:910156
Mahendra G, Pandit H, Kliskey K, Murray D, Gill HS, Athanasou N (2009) Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties. Acta Orthop 80:653–659
Koster R, Vieluf D, Kiehn M et al (2000) Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 356:1895–1897
Saito T, Hokimoto S, Oshima S, Noda K, Kojyo Y, Matsunaga K (2009) Metal allergic reaction in chronic refractory in-stent restenosis. Cardiovasc Revasc Med 10:17–22
Banerji A, Lax T, Guyer A, Hurwitz S, Camargo CA Jr, Long AA (2014) Management of hypersensitivity reactions to Carboplatin and Paclitaxel in an outpatient oncology infusion center: a 5-year review. J Allergy Clin Immunol Pract 2:428–433
Pfoch L, Mahler V, Sticherling M (2009) Drug-eluting coronary stents: hypersensitivity reactions to paclitaxel. A case report. Dermatology 218:52–55
Nakazawa G (2011) Stent thrombosis of drug eluting stent: pathological perspective. J Cardiol 58:84–91
Svedman C, Moller H, Gruvberger B et al (2014) Implants and contact allergy: are sensitizing metals released as haptens from coronary stents? Contact Dermatitis 71:92–97
Halwani DO, Anderson PG, Lemons JE, Jordan WD, Anayiotos AS, Brott BC (2010) In-vivo corrosion and local release of metallic ions from vascular stents into surrounding tissue. J Invasive Cardiol 22:528–535
Svedman C, Ekqvist S, Moller H et al (2009) A correlation found between contact allergy to stent material and restenosis of the coronary arteries. Contact Dermatitis 60:158–164
Thyssen JP, Engkilde K, Menne T, Johansen JD, Hansen PR, Gislason GH (2011) No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis—results from a linkage study. Contact Dermatitis 64:138–141
Gimenez-Arnau A, Riambau V, Serra-Baldrich E, Camarasa JG (2000) Metal-induced generalized pruriginous dermatitis and endovascular surgery. Contact Dermatitis 43:35–40
Guerra A, Kirkwood M (2017) Severe generalized dermatitis in a nickel-allergic patient with a popliteal artery nitinol stent. J Vasc Surg Cases Innov Tech 3:23–25
Jetty P, Jayaram S, Veinot J, Pratt M (2013) Superficial femoral artery nitinol stent in a patient with nickel allergy. J Vasc Surg 58:1388–1390
D’Arrigo G, Giaquinta A, Virgilio C, Davi A, Pierfrancesco V, Veroux M (2014) Nickel allergy in a patient with a nitinol stent in the superficial femoral artery. J Vasc Interv Radiol 25:1304–1306
Khan SF, Sherbondy MA, Ormsby A, Velanovich V (2007) Occlusion of metallic biliary stent related to nickel allergy. Gastrointest Endosc 66:413–414
Prestipino F, Pragliola C, Lusini M, Chello M (2014) Nickel allergy induced systemic reaction to an intracardiac amplatzer device. J Card Surg 29:349–350
Spina R, Muller DW, Jansz P, Gunalingam B (2016) Nickel hypersensitivity reaction following Amplatzer atrial septal defect occluder device deployment successfully treated by explantation of the device. Int J Cardiol 223:242–243
Rigatelli G, Cardaioli P, Giordan M et al (2007) Nickel allergy in interatrial shunt device-based closure patients. Congenit Heart Dis 2:416–420
Kang J, Simpson CS, Campbell D et al (2013) Cardiac rhythm device contact dermatitis. Ann Noninvasive Electrocardiol 18:79–83
Citerne O, Gomes S, Scanu P, Milliez P (2011) Painful Eczema mimicking pocket infection in a patient with an ICD: a rare cause of skin allergy to nickel/cobalt alloy. Circulation 123:1241–1242
Andrews ID, Scheinman P (2011) Systemic hypersensitivity reaction (without cutaneous manifestations) to an implantable cardioverter-defibrillator. Dermatitis 22:161–164
Abdallah HI, Balsara RK, O’Riordan AC (1994) Pacemaker contact sensitivity: clinical recognition and management. Ann Thorac Surg 57:1017–1018
Delaplace M, Maitre F, Dufour T et al (2010) Two cases of cutaneous erythema following spinal cord stimulation. Ann Dermatol Venereol 137:297–300
Taverner MG (2013) A case of an allergic reaction to a spinal cord stimulator: identification of the antigen with epicutaneous patch testing, allowing successful reimplantation. Neuromodulation 16:595–599
Schmidlin K, Verzwyvelt J, Bernstein D, Kim H (2015) Probable delayed-type hypersensitivity to nickel-containing cerebral aneurysm clip associated with neurologic deficits. J Allergy Clin Immunol Pract 3:609–611
Gautschi OP, Schlett CL, Fournier JY, Cadosch D (2010) Laboratory confirmed polymethyl-methacrylate (Palacos)-hypersensitivity after cranioplasty. Clin Neurol Neurosurg 112:915–916
King L Jr, Fransway A, Adkins RB (1993) Chronic urticaria due to surgical clips. N Engl J Med 329:1583–1584
Fage SW, Muris J, Jakobsen SS, Thyssen JP (2016) Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity. Contact Dermatitis 74:323–345
Keane FM, Morris SD, Smith HR, Rycroft RJ (2001) Allergy in coronary in-stent restenosis. Lancet 357:1205–1206 author reply 1206–1207
Goon AT, Bruze M, Zimerson E et al (2011) Variation in allergen content over time of acrylates/methacrylates in patch test preparations. Br J Dermatol 164:116–124
Goon AT, Bruze M, Zimerson E et al (2011) Correlation between stated and measured concentrations of acrylate and methacrylate allergens in patch-test preparations. Dermatitis 22:27–32
Pacheco K, Barker L, Maier L, Erb S, Sills M, Knight V (2013) Development of a validated blood test for nickel sensitization. J Allergy Clin Immunol 132:767–769
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Ethical Approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Rights and permissions
About this article
Cite this article
Pacheco, K.A. Allergy to Surgical Implants. Clinic Rev Allerg Immunol 56, 72–85 (2019). https://doi.org/10.1007/s12016-018-8707-y
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12016-018-8707-y