Abstract

There are many sources of indoor air pollution in any residence, including combustion sources of tobacco smoke, cooking, engines, heating equipment, and fireplace. Indoor air quality is very important especially for the elderly who spend most of the day indoors, but there are limited studies on warrens of Bangkok, Thailand. This study evaluated volatile organic compounds (VOCs)—benzene, toluene, ethylbenzene, and xylene (BTEX)—and carbonyl compounds (CCs) in elderly residences of five warrens in an urban area in Bangkok. All active indoor and outdoor air samples during a 24-h period were applied to charcoal tubes for BTEX analyses using GC/FID and 2,4-dinitrophenylhydrazine (DNPH) cartridge for CC analyses by HPLC/UV. The median indoor VOC concentrations of benzene, toluene, ethylbenzene, xylene, formaldehyde, acetaldehyde, propionaldehyde, and valeraldehyde were 13.29, 128.51, 5.37, 16.16, 11.41, 4.81, 0.76, and 0.21 μg/m3, respectively. Total indoor VOC concentration (BTEX + CCs) of these warrens ranged from 142.32 to 272.31 μg/m3, which was higher than the outdoor VOC level. Indoor formaldehyde concentration was shown significantly higher than outdoor concentration (p < 0.01). The average lifetime cancer risks of benzene, ethylbenzene, formaldehyde, and acetaldehyde among elderly residences were 1.79E−05, 0.33E−05, 4.70E−05, and 1.02E−05, respectively, which are higher than the acceptable level. Also, hazard index (HI) was harmful to human health (HI > 1). The VOC concentrations were related to health status, specific symptoms of colds, skin irritation, and non-specific symptoms of dizziness and headache. The VOC concentrations were affected by elderly behaviors of indoor smoking (p < 0.01), mosquito repellent/insecticide spraying (p < 0.05), indoor environments of air conditioning (p < 0.001), and exhaust fan (p < 0.001). In conclusion, the elderly in urban warrens had health risk from indoor air quality, which was related to their behaviors. Good ventilation and health promotion should be recommended.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  • Azuma K, Uchiyama I, Ikeda K (2007) The risk screening for indoor air pollution chemicals in Japan. Risk Anal 27(6):1623–1638

    Article  Google Scholar 

  • Bentayeb M, Simoni M, Norback D, Baldacci S, Maio S, Viegi G, Annesi-Maesano I (2013) Indoor air pollution and respiratory health in the elderly. J Environ Sci Health A Tox Hazard Subst Environ Eng 48(14):1783–1789

    Article  CAS  Google Scholar 

  • Bernstein JA, Alexis N, Bacchus H, Bernstein IL, Fritz P, Horner E, Li N, Mason S, Nel A, Oullette J, Reijula K, Reponen T, Seltzer J, Smith S, Tarlo SM (2008) The health effects of non-industrial indoor air pollution. J Allergy Clin Immunol 121(3):585–591

    Article  CAS  Google Scholar 

  • Brickus LSR, Cardoso JN, De Aquino Neto FR (1998) Distributions of indoor and outdoor air pollutants in Rio de Janeiro, Brazil: implications to indoor air quality in bayside offices. Environ Sci Technol 32(22):3485–3490

    Article  CAS  Google Scholar 

  • Brown RH (2002a) Monitoring volatile organic compounds in air—the development of ISO standards and a critical appraisal of the methods. J Environ Monit 4(6):112N–118N

    Article  CAS  Google Scholar 

  • Brown SK (2002b) Volatile organic compounds in new and established buildings with Melbourne, Australia. Indoor Air 12:55–63

    Article  CAS  Google Scholar 

  • Clarisse B, Laurent AM, Seta N, LeMoullec Y, El Hanaoui A, Momas I (2003) Indoor aldehydes: measurement of contamination levels and identification of their determinants in Paris dwellings. Environ Res 92:245–253

    Article  CAS  Google Scholar 

  • Clark ML, Reynolds SJ, Burch JB, Conway S, Bachand AM, Peel JL (2010) Indoor air pollution, cookstove quality, and housing characteristics in two Honduran communities. Environ Res 110(1):12–18

    Article  CAS  Google Scholar 

  • Colledge NR, Barr-Hamilton RM, Lewis SJ, Sellar RJ, Wilson JA (1996) Evaluation of investigations to diagnose the cause of dizziness in elderly people: a community based controlled study. BMJ 313 doi: 10.1136/bmj.313.7060.788

  • Daisey JM, Angell WJ, Apte MG (2003) Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. Indoor Air 13:53–64

    Article  CAS  Google Scholar 

  • Dingle P, Tan R, Cheong C (2000) Formaldehyde in occupied and unoccupied caravans in Australia. Indoor Built Environ 9(3–4):233–236

    Article  CAS  Google Scholar 

  • Esplugues A (2010) Indoor and outdoor air concentrations of BTEX and determinants in a cohort of one-year old children in Valencia, Spain. Sci Total Environ 409(1):63–69

    Article  CAS  Google Scholar 

  • FISIAQ (1995) Finnish Society of Indoor Air Quality and Climate, Finnish Association of Construction Clients/RAKI, Finnish Association of Architects/SAFA, Finnish Association of Consulting Firms/SKOL. Classification of indoor climate, construction and furnishing materials. Helsinki.

  • Franklin PJ (2007) Indoor air quality and respiratory health of children. Paediatr Respir Rev 8(4):281–286

    Article  Google Scholar 

  • Gelencsér A, Siszler K, Hlavay J (1997) Toluene–benzene concentration ratio as a tool for characterizing the distance from vehicular emission sources. Environ Sci Technol 31(10):2869–2872

    Article  Google Scholar 

  • Gilbert NL, Guay M, Miller JD, Judek S, Chan CC, Dales RE (2005) Levels and determinants of formaldehyde, acetaldehyde, and acrolein in residential indoor air in Prince Edward Island, Canada. Environ Res 99(1):11–17

    Article  CAS  Google Scholar 

  • Guo H, Lee SC, Li WM, Cao JJ (2003) Source characterization of BTEX in indoor microenvironments in Hong Kong. Atmos Environ 37(1):73–82

    Article  CAS  Google Scholar 

  • Gustafson P, Barregard L, Lindahl R, Sallsten G (2005) Formaldehyde levels in Sweden: personal exposure, indoor, and outdoor concentrations. J Expo Anal Environ Epidemiol 15:252–260

    Article  CAS  Google Scholar 

  • Haseen F, Adhikari R, Soonthorndhada K (2010) Self-assessed health among Thai elderly. BMC Geriatrics, 10:30, Chile. http://link.springer.com/article/10.1186%2F1471-2318-10-30#. Accessed 10 Oct 2013

  • Ho KF, Lee SC, Tsai WY (2006) Carbonyl compounds in the roadside environment of Hong Kong. J Hazard Mater 133(1–3):24–29

    Article  CAS  Google Scholar 

  • Hun DE, Corsi RL, Morandi MT, Siegel JA (2010) Formaldehyde in residences: long-term indoor concentrations and influencing factors. Indoor Air 20:196–203

    Article  CAS  Google Scholar 

  • IARC (2004) Tobacco smoke and involuntary smoke—IARC monographs on the evaluation of carcinogenic risks to humans. vol. 83, International Agency for Research on Cancer, ISBN 92-832-1283-5, Lyon, France

  • IARC (2011) Agents classified by the IARC monographs. International Agency for Research on Cancer http://monographs.iarc.fr/ENG/Classification/ClassificationsAlphaOrder.pdf. Accessed 12 Oct 2013

  • IPCS (1993) Benzene. Geneva, World Health Organization, International Programme on Chemical Safety (Environmental Health Criteria 150; http://www.inchem.org/documents/ehc/ehc/ehc150.htm). Accessed 8 Oct 2014

  • Kitwattanavong M, Prueksasit T, Morknoy D, Tunsaringkarn T, Siriwong W (2013) Health risk assessment of petro station workers in the inner city of Bangkok, Thailand, to the exposure to BTEX and carbonyl compounds by inhalation. Hum Ecol Risk Assess 19:1424–1439

    Article  CAS  Google Scholar 

  • Krol S, Zabiegała B, Namieśnik J (2011) Monitoring and analytics of semivolatile organic compounds (SVOCs) in indoor air. Anal Bioanal Chem 400(6):1751–1769

    Article  CAS  Google Scholar 

  • Levy JI, Lee K, Spengler JD, Yanagisawa Y (1998) Impact of residential nitrogen dioxide exposure on personal exposure: an international study. J Air Waste Manag Assoc 48(6):553–560

    Article  CAS  Google Scholar 

  • Mentese S, Gullu G (2006) Variations and sources of formaldehyde levels in residential indoor air in Ankara, Turkey. Indoor Built Environ 15(3):273–281

    Article  CAS  Google Scholar 

  • Molhave L (2003) Organic compounds as indicators of air pollution. Indoor Air 13:12–19

    Article  Google Scholar 

  • Morknoy D, Khummongkol P, Prueksasit T (2011) Seasonal and diurnal concentrations of ambient formaldehyde and acetaldehyde in Bangkok. Water Air Soil Poll 216:693–702

    Article  CAS  Google Scholar 

  • Myers I, Maynard RL (2005) In-depth review: polluted air—outdoors and indoors. Occup Med 55:432–438. doi:10.1093/occmed/kqi137

    Article  CAS  Google Scholar 

  • NHMRC (1993) Volatile organic compounds in indoor air. National Health and Medical Research Council, Report of the 115th Session. http://soer.justice.tas.gov.au/2003/source/140/index.php. Accessed 5 Oct 2013

  • Nielsen E, Ostergaard G, Larsen JC (2008) Toxicological risk assessment of chemicals. Informa Healthcare, New York

    Book  Google Scholar 

  • Niemi C (2013) “Acceptable” risk levels for carcinogens: their history, current use, and how they affect surface water quality criteria. Policy Forum #3, Human Health Criteria and Implementation Tools Rule-makings. http://www.tmw-law.com/news-pdf/SWQSPolicyForumRiskLevel%2002-08-213.pdf. Accessed 5 Aug 2014

  • OH&S (Occupational Health & Safety) The University of Queensland (2000) Indoor air quality management plan. http://www.uq.edu.au/ohs/pdfs/pol-indoorair.pdf. Accessed 15 Oct 2013

  • Ongwandee M, Moonrinta R, Panyametheekul S, Tangbanluekal S, Morrison G (2011) Investigation of volatile organic compounds in office buildings in Bangkok, Thailand: concentrations, sources, and occupant symptoms. Build Environ 46:1512–1522

    Article  Google Scholar 

  • OpenToxipedia (2010) Hazard index. http://www.opentoxipedia.org/index.php/Hazard_Index. Accessed 8 Aug 2014

  • Parao AE (2012) Volatile organic compounds in urban and industrial areas in the Philippines. Faculty of Bioscience Engineering Center for Environmental Science and Technology Academic year 2011–2012. Universitiet Gent. http://lib.ugent.be/fulltxt/RUG01/001/894/382/RUG01-001894382_2012_0001_AC.pdf. Accessed 3 Nov 2013

  • Peng C-Y, Lan C-H, Wu T-J (2009) Investigation of indoor chemical pollutants and perceived odor in an area with complaints of unpleasant odors. Build Environ 44:2106–2113

    Article  Google Scholar 

  • Sax SN, Bennett DH, Chillrud SN, Ross J, Kinney PL, Spengler JD (2006) A cancer risk assessment of inner-city teenagers living in New York City and Los Angeles. Environ Health Perspect 114:1558–1566

    Article  CAS  Google Scholar 

  • Seifert B (1990) Indoor air ’90. In: Walkinshaw DS (ed). Proceedings of 5th international conference on indoor air quality and climate. July 29–August 5, Toronto, Canada, p 35

  • Sexton K, Mongin SJ, Adgate JL, Pratt GC, Ramachandran G, Stock TH, Morandi MT (2007) Estimating volatile organic compound concentrations in selected microenvironments using time-activity and personal exposure data. J Toxicol Environ Health A 70:465–476

    Article  CAS  Google Scholar 

  • Shendell DG, Winer AM, Stock TH, Zhang L, Zhang J, Maberti S, Colome SD (2004) Air concentrations of VOCs in portable and traditional classrooms: results of a pilot study in Los Angeles County. J Expo Anal Environ Epidemiol 14:44–59

    Article  CAS  Google Scholar 

  • Simoni M, Jaakkola MS, Carrozzi L, Baldacci S, Di Pede F, Viegi G (2003) Indoor air pollution and respiratory health in the elderly. ERJ 21(40):15s–20s. doi:10.1183/09031936.03.00403603

    Article  CAS  Google Scholar 

  • Slezakova K, Morais S, do Carmo Pereira M (2012) Indoor air pollutants: relevant aspects and health impacts. Environmental Health—Emerging Issues and Practice. ISBN 978-953-307-854-0, Hard cover, 324 pages. http://cdn.intechopen.com/pdfs/27683/InTechIndoor_air_pollutants_relevant_aspects_and_health_impacts.pdf. Accessed 20 Nov 2013

  • Sofuoglu SC, Aslan G, Inal F, Sofuoglu A (2011) An assessment of indoor air concentrations and health risks of volatile organic compounds in three primary schools. Int J Hyg Environ Health 214:36–46

    Article  CAS  Google Scholar 

  • Son B, Breysse P, Yang W (2003) Volatile organic compounds concentrations in residential indoor and outdoor and its personal exposure in Korea. Environ Int 29(1):79–85

    Article  CAS  Google Scholar 

  • Tang X, Bai Y, Duong A, Smith MT, Li L, Zhang L (2009) Formaldehyde in China: production, consumption, exposure levels, and health effects. Environ Int 8:1210–1224

    Article  Google Scholar 

  • Tunsaringkarn T, Siriwong W, Prueksasit T, Sematong S, Zapuang K, Rungsiyothin A (2012a) Potential risk comparison of formaldehyde and acetaldehyde exposures in office and gasoline station workers. IJSRP 2:2250–3153

    Google Scholar 

  • Tunsaringkarn T, Siriwong W, Rungsiyothin A, Nopparatbundit S (2012b) Occupational exposure of gasoline station workers to BTEX compounds in Bangkok, Thailand. Int J Occup Environ Med 3:117–125

    CAS  Google Scholar 

  • UNFPA Thailand (2006) Population ageing in Thailand: prognosis and policy response. http://thailand.unfpa.org/documents/thai_ageing_englishversion.pdf. Accessed 25 Oct 2013

  • US EPA (1989) Risk assessment guidance for superfund, Volume I, Human health evaluation manual (Part A), Interim Final, EPA/540/1-89-002, December 1989

  • US EPA (1990) Science Advisory Board: reducing risk-setting priorities and strategies for environmental protection, SAB-EC-90-021

  • US EPA (1991) Risk assessment guidance for superfund, Volume I, Human health evaluation manual (Part B, Development of risk-based preliminary remediation goals), Interim Final, OSWER 9285.7-01B, December 1991

  • US EPA (1993) What you can do about secondhand smoke as parents, decision-makers, and building occupants. Washington, DC: US Environmental Protection Agency. http://www.epa.gov/smokefree/pubs/etsbro.html. Accessed 8 Aug 2014

  • US EPA (1996) IAQ a concern in EPA’s planned 232-million research facility. Indoor Air Quality Updates 9 10:8–13

    Google Scholar 

  • US EPA (1997) Guiding principles for Monte Carlo analysis. Risk assessment forum. EPA/630/R-97/001, Washington, DC

  • US EPA (1999a) Compendium method TO-17, determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes, 2nd edn. Environmental Protection Agency, Cincinnati, OH

    Google Scholar 

  • US EPA (1999b) Compendium method TO-11, determination of formaldehyde in ambient air using adsorbent cartridge followed by high performance liquid chromatography (HPLC). Environmental Protection Agency, Cincinnati, OH

    Google Scholar 

  • US EPA (2012a) An introduction to indoor air quality (IAQ): volatile organic compounds (VOCs). http://www.epa.gov/iaq/voc.html#content. Accessed 5 Dec 2013

  • US EPA (2012b) Publications and resources: the inside story: a guide to indoor air quality. http://www.epa.gov/iaq/pubs/insidestory.html#IAQHome. Accessed 23 Oct 2013

  • US EPA (2013) An introduction to indoor air quality (IAQ). http://www.epa.gov/iaq/ia-intro.html. Accessed 8 Dec 2013

  • US EPA (2014) HH: risk characterization. http://www2.epa.gov/region8/hh-risk-characterization#noncancer. Accessed 5 Aug 2014

  • Wheeler AJ, Wong SL, Khong C, Zhu J (2013) Predictors of indoor BTEX concentrations in Canadian residences. Health Rep 24(5):11–17

    Google Scholar 

  • WHO (2000) Air quality guidelines, 2nd edition, WHO Regional Publications, European Series No. 91, ISBN 92-890-1358-3, Copenhagen, Denmark

  • WHO (2010) WHO guidelines for indoor air quality: selected pollutants. WHO Regional Office for Europe, ISBN 978-92-890-0213-4, Copenhagen, Denmark

  • WHO (2011) Global health and aging. National Institute on Aging, National Institute of Health, US Department of Health and Human Services. NIH Publication no. 11-7737, October. http://www.who.int/ageing/publications/global_health.pdf. Accessed 3 Nov 2013

  • Zabiegała B, Górecki T, Przyk E, Namieśnik J (2002) Permeation passive sampling as a tool for the evaluation of indoor air quality. Atmos Environ 36(17):2907–2916

    Article  Google Scholar 

  • Zhang Z, Guo B, Zhang JS (2003) Determination of volatile organic compounds in residential buildings, July 21–23. Research Triangle Park, NC. http://c.ymcdn.com/sites/www.nibs.org/resource/resmgr/BEST/BEST1_008.pdf. Accessed 2 Dec 2013

  • Zhang Y, Mo J, Weschler CJ (2013) Supplemental material reducing health risks from indoor exposures in rapidly developing urban China. Environ Health Perspect 121(7):751–755

    Article  Google Scholar 

Download references

Acknowledgments

This study was solely supported by the Integrated Innovation Academic Center (IIAC), Chulalongkorn University Centenary Academic Development Project (CU56-AS06), the College of Public Health Sciences, Chulalongkorn University, and the Environmental Resources Training Center (ERTC), Ministry of Natural Resources and Environment, provided facilities and instruments. The authors thank Dr. Chandrika Ramakrishnan for her advice and reviewing this paper.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tanasorn Tunsaringkarn.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tunsaringkarn, T., Prueksasit, T., Morknoy, D. et al. Indoor air assessment, health risks, and their relationship among elderly residents in urban warrens of Bangkok, Thailand. Air Qual Atmos Health 8, 603–615 (2015). https://doi.org/10.1007/s11869-014-0302-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11869-014-0302-7

Keywords

Navigation