Abstract
The typical starting current for an asynchronous three-phase electric motor is in the range of five to ten times the rated current. To mitigate problems caused by this high current, various methods to start this type of motor exist. As an alternative method for starting up induction motors, a new starting current limitation method is proposed, which is based on using commercially available high-temperature superconductor tape. A prototype of the superconducting starting current limiter was constructed and tested with a 55-kW industrial induction motor, in a 440-V/60-Hz three-phase power grid. As the total starting time can be longer than the time the superconductor tape can support a high current, a shunt reactor receives the starting current after 80 ms to avoid damage to the tape. Performance evaluations of the superconducting limiter method were performed and were compared with a direct-on-line starter and an electronic soft starter. In addition to limiting the starting current, our method offers reduced current waveform distortion and lower harmonic pollution during startup.
Similar content being viewed by others
References
Sen, P.C.: Principles of Electric Machines and Power Electronics, 3rd edn. Wiley, New York (2013)
Ghodhbani, L., Rebhi, B., Kourda, F., Elleuch, M., Abidi, M.: Comparison among electronic startup methods for induction motors. IEEE 7th Int. Multi-Conf. on Syst. Signals and Devices (2010)
Noe, M., Steurer, M.: High-temperature superconductor fault current limiters: Concepts, applications and development status. Supercond. Sci. Technol. 20(3), R15–R29 (2007)
Gandioli, C., Tixador, P., Mariani, G.B.: Tests and simulations of different YBCO tape for FCL. IEEE Trans. App. Supercond. 22, 56003104 (2012)
Schmidt, W., Kraemer, H.-P., Neumueller, H.-W., Schoop, U., Verebelyi, D., Malozemoff, A.P.: Investigation of YBCO coated conductors for fault current limiter applications. IEEE Trans. App. Supercond. 17(2), 3471–3474 (2007)
Schacherer, C., et al.: Dissipated energy as a design parameter of coated conductor for their use in resistive fault current limiters. J. Phys. Conf. Ser. 97, 012193 (2008)
Acknowledgments
This work has been supported by FAPES and CNPq—PRONEX 48508675/2009 and Universal 54694825/2011. The experimental results were obtained in the laboratory of electric motors in Tubarão Complex/VALE SA with the help of the electrical engineer Flavio Helmer Ferro.
Author information