Skip to main content
Log in

Magneto-thermal Coupling Modeling for the Stability Analysis of a 110 kV/3 kA High Temperature Superconducting Cable under Fault Current Conditions

  • Original Paper
  • Published:
Journal of Superconductivity and Novel Magnetism Aims and scope Submit manuscript

Abstract

In the power grid, the cold dielectric hightemperature superconducting (CD HTS) cable frequently subjects to overcurrents caused by the shortcircuit fault. During the fault, a large amount of Joule heat is generated. The heat causes the temperature of the HTS cable to rise and leads to the transition of the HTS cable from superconducting state to normal state which would influence the current carrying capacity of the HTS cable seriously. An algorithm has been proposed to calculate the transient current distributions of superconducting layers in fault conditions. This method couples an equivalent circuit model and a thermal model. So the temperature distributions in HTS cable is obtained based on the heat generated by the fault current. Finally, the current and temperature distributions of a 110 kV/3 kA CD HTS cable are investigated with a fault current impact of 25 kA rms for 3 s. The results show that the currents of the conducting layers decrease while the temperature increases in the HTS cable and the former withstands most of the fault current impacts. The current in the former of the HTS cable changes from zero to about 90 % of the fault current. A current diversion effect in the HTS cable is obvious. The conclusions provide the basis for the protection strategy of superconducting cable considering fault current impact and will be a benefit to the stable operation of a superconducting transmission grid.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Masuda, T.: Recent progress of HTS cable project. Physica. C (2008). doi:10.1016/j.physc.2008.05.259

  2. Maguire, J.F., Yuan, J., et al.: Progress and status of a 2G HTS power cable to be installed in the Long Island Power Authority (LIPA) grid doi:10.1109/TASC.2010.2093108 (2011)

  3. Kim, S., Cho, J., Sim, K.-D., Bae, J.-H., Kim, J.-H., Lee, C.-Y., Jang, H.-M.: Investigation on the thermal behavior of HTS power cable under fault current doi:10.1109/TASC.2005.864320 (2006)

  4. Wang, X., Ishiyama, A., Ohya, M., Maruyama, O., Ohkuma, T.: Overcurrent tests and numerical simulations on a 66-kV-Class RE123 High-Temperature Superconducting model cable doi:10.1109/TASC.2011.2178973

  5. Sato, S., Wang, X., Ueda, H., Ishiyama, A., Yagi, M., Mukoyama, S., Saitoh, T., Aoki, Y., Fujiwara, N.: Computer simulation of fault current characteristics in 275 kV class YBCO power cable. Phys. C: Supercond. doi:10.1016/j.physc.2010.05.164

  6. Zhou, Z., Zhu, J., Li, H., Qiu, M., Li, Z., Ding, K., Wang, y.: Magnetic-thermal coupling analysis of the cold dielectric high temperature superconducting cable. IEEE Trans. Appl. Supercond. (2013). doi:10.1109/TASC.2012.2236377

  7. Olsen, S.K., Traholt, C., Kuhle, A., et al.: Loss and inductance investigation in a 4-layer superconducting prototype cable conductor. IEEE Trans. Appl. Supercond. (1999). doi:10.1109/77.783426

  8. Zhu, J., Bao, X., Guo, L., Xia, Z., Qiu, M., Yuan, W.: Optimal design of current sharing in transmission conductors of a 110 kV/3 kA cold dielectric superconducting cable consisted of YBCO tapes. IEEE Trans. Appl. Supercond. (2013). doi:10.1109/TASC.2013.2244156

Download references

Acknowledgments

All the authors would like to thank the support by NSFC Grant 51207146, EPSRC EP/K01496X/1 and RAEng Research Exchange scheme of UK and the State Grid Corporation of China.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jiahui Zhu.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhu, J., Li, H., Qiu, M. et al. Magneto-thermal Coupling Modeling for the Stability Analysis of a 110 kV/3 kA High Temperature Superconducting Cable under Fault Current Conditions. J Supercond Nov Magn 28, 607–613 (2015). https://doi.org/10.1007/s10948-014-2666-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10948-014-2666-1

Keywords

Navigation