In order to investigate the eddy current loss of metallic building wall which is penetrated by AC busbar, the 3D finite element model has been created, the eddy current loss in a building wall have been analyzed for different operational condition. Through the comparison between the different simulation results, the most important influencing factors on eddy current loss of building wall are analyzed. The simulation results show that the eddy current loss is directly proportional to bulk conductivity and relative permeability, phase sequence of AC busbar and air gap of building wall have little effects on eddy current loss of building wall. Finally, required shielding of AC busbar, which satisfy the design requirement, is proposed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. I. Song, J. Thomsen, J. Tao et al., Fault analysis of ITER coil Power supply system. Power Syst. Remote Sens. 32, 153 (2009)

    Google Scholar 

  2. P. Libeyre, B. Bareyt, I. Benfatto et al., Electrical design requirements on the ITER coils. IEEE Trans. Appl. Supercond. 18, 479 (2008)

    Article  ADS  Google Scholar 

  3. P. Fu, G. Gao, ZhQ Song, L.W. Xu, L.S. Huang, L. Jiang, J.C. Li, F.W. Zha, L. Dong, M. Wang, Preliminary design of the poloidal field AC/DC converter system for the ITER coil power supply. Fusion Sci. Technol. 64, 4 (2013)

    Google Scholar 

  4. ANSYS software document, version14 (2012)

  5. A.M. Niknejad, R.G. Meyer, Analysis of eddy-current losses over conductive substrates with applications to monolithic inductors and transformers. IEEE Trans. Microw. Theor. Tech. 49, 166 (2001)

    Article  ADS  Google Scholar 

  6. P. Reynaud, Building integration, ITER document, France (ITER_D_6LDTHP) (2012)

  7. J. Barranger, Hysteresis and eddy current losses of a transformer lamination viewed as an application of the Poynting theorem. NASA technical Note, USA (1965)

  8. W. Lijian, H. Jinyi, Y. Ruitang et al., Theorem and Design of Huge Current Busbar (Water Resources and electric power press, Beijing, 1983). in Chinese

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to L. Jiang.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jiang, L., Gao, G., Xu, L.W. et al. 3D Finite Element Analysis on Eddy Current Loss in Metallic Building Wall. J Fusion Energ 34, 49–53 (2015). https://doi.org/10.1007/s10894-014-9757-7

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10894-014-9757-7

Keywords

Navigation