Abstract
Insufficient bonding of juxtaposed bone to an orthopaedic/dental implant could be caused by material surface properties that do not support new bone growth. For this reason, fabrication of biomaterials surface properties, which support osteointegration, should be one of the key objectives in the design of the next generation of orthopaedic/dental implants. Titanium and titanium alloy have been widely used in several bioimplant applications, but when implanted into the human body, these still contain some disadvantages, such as poor osteointegration (forming a fibrous capsule), wear debris and metal ion release, which often lead to clinical failure. Electrolytic hydroxyapatite/titanium dioxide (HA/TiO2) double layers were successfully deposited on titanium substrates in TiCl4 solution and subsequently in the mixed solution of Ca(NO3)2 and NH4H2PO4, respectively. After annealing at 300∘C for 1 h in the air, the coated specimens were evaluated by dynamic cyclic polarization tests, immersion tests, tensile tests, surface morphology observations, XRD analyses and cells culture. The adhesion strength of the HA coating were improved by the intermediate coating of TiO2 from 11.3 to 46.7 MPa. From cell culture and immersion test results, the HA/TiO2 coated specimens promoted not only cells differentiation, but also appeared more bioactive while maintaining non-toxicity.
Similar content being viewed by others
References
F. WATARI, A. YOKOYAMA, F. SASO, M. UO and T. KAWASAKI, Composites Part B: Eng. 28B (1997) 5.
P. L. BATAILLON, F. MONCHAU, M. BIGERELLE and H. F. HILDEBRAND, Biomol. Eng. 19 (2002) 133.
C. H. KU, D. P. PIOLETTI, M. BROWNE and P. J. GREGSON, Biomaterials 23 (2002) 1447.
I. DEGASNE, M. F. BASLE, V. DEMAIS, G. HURE, M. LESOURD, B. GROLLEAU, L MERCIER and D. CHAPPARD, Calcif. Tissue Int. 64 (1999) 499.
X. NIE, A. LEYLAND and A. MATTHEWS, Surf. Coat. Technol. 125 (2000) 407.
H. KURZWEG, R. B. HEIMANN, T. TROCZYNSKI and M. L. WAYMAC, Biomaterials 19 (1998) 1507.
D. J. LI, K. OHSAKI, K. LI, PC. CUI, O. YE, K. BABA, Q. C. WANG, S. TENSIN and T. Y. TERUKO, J. Biomed. Mater. Res. 45 (1999) 322.
A. M. EKTESSABI and H. KIMURA, Thin Solid Films. 270 (1995) 335.
G. K. DE, R. GEESINK, CPAT. KLEIN and P. SEREKIAN, J. Biomed. Mater. Res. 121 (1987) 1357.
R. MCPHERSON and N. GANE, J. Mater. Sci.: Mater. Med. 6 (1995) 327.
H. KURZWEG and R. B. HEIMANN, Biomaterials 19 (1998) 1507.
K. V. DIJK, H. G. SCHAEKEN, J. G. G. WOLKE and J. A. JANSEN, ibid. 17 (1998) 159.
O. YOSHINO and M. MASAMICHI, Surf. Coat. Technol. 65 (1994) 224.
C. K. WANG and L. J. H. CHERN, Biomaterials 18 (1997) 1331.
R. DAMODARAN and B. M. MOUDGIL, Coll. Surf. A: Physicochem. Eng. Aspects 80 (1993) 191.
W. WENG and J. L. BAPTISTA, J. Am. Ceram. Soc. 82 (1999) 27.
W. WENG and J. L. BAPTISTA, J. Mater. Sci.: Mater. Med. 9 (1998) 159.
H. HERO, H. WIE and R. B. JORGENSEN, J. Biomed. Mater. Res. 28 (1994) 343.
P. G. BRADFORD, J. M. MAGLISH, A. S. PONTICELLI and K. L. KIRKWOOD, Arch. Oral Biol. 45 (2000) 159.
Designation: C-633. Standard test method for adhesion of cohesive strength of flame-sprayed coatings, “Annual Book of ASTM Standards,” (American Society for testing and materials, Philadelphua, PA, 1993) Vol. 3.01, p. 665.
H. M. KIM, F. MIYAJI, T. KOKUBO and T. NAKAMURA, J. Biomed. Mater. Res. 38 (1997) 121.
T. KOKUBO, H. M. KIM and M. KAWASHITA, Biomaterials 24 (2003) 2161.
S. K. YEN and C. M. LIN, J. Electrochem. Soc. 149 (2002) 79.
K. L. KIRKWOOD, R. DZIAK and P. G. BRADFORD, J. Bone Mineral. Res. 11 (1996) 1889.
P. A. RAMIRES, A. ROMITO, F. COSENTINO and E. MILELLA, Biomaterials 22 (2001) 1467.
O. H. LOWRY, N. R. ROBERTS, M. L. WU, W. S. HIXON and E. J. CRAWFORD, J. Biomed. Chem. 207 (1954) 19.
R. J. MAJESKA, J. T. RYABY and T. A. EINHORN, J. Orth. Res. 20 (2002) 281.
S. K. YEN and C. M. LIN, Mater. Chem. Phys. 77 (2002) 70.
C. M. LIN and S. K. YEN, in Proceedings of the 8th Biomedical Materials and Technology Symposium, Taiwan, ROC September (2003) p. A101.
A. BEN-ZE’EV, Curr. Opin. Cell Biol. 9 (1997) 99.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lin, CM., Yen, SK. Characterization and bond strength of electrolytic HA/TiO2 double layers for orthopaedic applications. J Mater Sci: Mater Med 16, 889–897 (2005). https://doi.org/10.1007/s10856-005-4423-2
Received:
Accepted:
Issue Date: