Skip to main content
Log in

Experience operating a thermal configuration without a deaerator at the 330 MW unit 3 of the Kashira GRÉS

  • Published:
Power Technology and Engineering Aims and scope

The operating experience gained during introduction of a configuration without a deaerator at the 330 MW unit No. 3 of the Kashira GRÉS is analyzed. The basic advantages of this configuration are pointed out, along with ways of overcoming the difficulties that were encountered during installation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. V. F. Ermolov, V. A. Permyakov, G. I. Efimochkin, and V. A. Verbitskii, Mixing Preheaters for Steam Turbines [in Russian], Énergoizdat, Moscow (1982).

    Google Scholar 

  2. G. I. Efimochkin, Configurations Without Deaerators for Steam-Turbine Units [in Russian], Énergoatomizdat, Moscow (1989).

    Google Scholar 

  3. E. A. Kin, “Calculating the optimum position for the feed pump in a scheme for regenerative preheating of feed water,” Izv. vuzov. Ser. Énergetika, No. 5 (1960).

  4. N. N. Trifonov, Improvements in the Regeneration System for Steam-Turbine Units with Low-Pressure Mixing Heat Exchangers Taking Transient Regimes into Account. Author’s Abstract of Candidate’s Thesis [in Russian], Leningrad (1984).

  5. N. N. Trifonov, E. V. Kovalenko, I. V. Ignat’ev, and Yu. V. Shalkevich, “Modernization of configuration and components in the condensate-feed loop and related equipment in turbine units at thermal and nuclear power plants,” Teploénergetika, No. 2 (2006).

  6. N. N. Trifonov, Yu. G. Sukhorukov, V. F. Ermolov, and E. V. Kovalenko, “Experience in and proposals for the choice of technical solutions in the development and modernization of thermal configurations without a deaerator in modern power generation units,” Teploénergetika, No. 10 (2009).

  7. Yu. A. Radin, A. A. Lyubtsov, and O. N. Makarov, “Basic performance indicators of the PGU-450T steam-gas unit during operation in the district heating and electric power mode, Élektr. Stantsii, No. 12 (2011).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Translated from Élektricheskie Stantsii, No. 6, June 2012, pp. 22 – 26.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Avrutsky, G.D., Nikanorov, V.D., Kalinowskiy, I.R. et al. Experience operating a thermal configuration without a deaerator at the 330 MW unit 3 of the Kashira GRÉS. Power Technol Eng 46, 298–302 (2012). https://doi.org/10.1007/s10749-012-0348-3

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-012-0348-3

Keywords

Navigation