Abstract
Descemet Membrane Endothelial Keratoplasty (DMEK) selectively replaces the damaged posterior part of the cornea. However, the DMEK technique relies on a manually-performed dissection that is time-consuming, requires training and presents a potential risk of endothelial graft damages leading to surgery postponement when performed by surgeons in the operative room. To validate precut corneal tissue preparation for DMEK provided by a cornea bank in order to supply a quality and security precut endothelial tissue. The protocol was a technology transfer from the Netherlands Institute for Innovative Ocular Surgery (NIIOS) to Lyon Cornea Bank, after formation in NIIOS to the DMEK “no touch” dissection technique. The technique has been validated in selected conditions (materials, microscope) and after a learning curve, cornea bank technicians prepared endothelial tissue for DMEK. Endothelial cells densities (ECD) were evaluated before and after preparation, after storage and transport to the surgery room. Microbiological and histological controls have been done. Twenty corneas were manually dissected; 18 without tears. Nineteen endothelial grafts formed a double roll. The ECD loss after cutting was 3.3 % (n = 19). After transportation 7 days later, we found an ECD loss of 25 % (n = 12). Three days after cutting and transportation, we found 2.1 % of ECD loss (n = 7). Histology found an endothelial cells monolayer lying on Descemet membrane. The mean thickness was 12 ± 2.2 µm (n = 4). No microbial contamination was found (n = 19). Endothelial roll stability has been validated at 3 days in our cornea bank. Cornea bank technicians trained can deliver to surgeons an ECD controlled, safety and ready to use endothelial tissue, for DMEK by “no touch” technique, allowing time saving, quality and security for surgeons.
Similar content being viewed by others
References
Anshu A, Price MO, Price FW (2012) Risk of corneal transplant rejection significantly reduced with Descemet’s membrane endothelial keratoplasty. Ophthalmology 119(3):536–540
Bahar I, Kaiserman I, McAllum P et al (2008) Comparison of posterior lamellar keratoplasty techniques to penetrating keratoplasty. Ophthalmology 115(9):1525–1533
Bayyoud T, Röck D, Hofmann J et al (2012) Precut technique for Descemet’s membrane endothelial keratoplasty, preparation and storage in organ culture. Klin Monbl Augenheilkd 229(6):621–623
Brockmann T, Brockmann C, Maier A-K et al (2014) Clinicopathology of graft detachment after Descemet’s membrane endothelial keratoplasty. Acta Ophthalmol (Cph) 92(7):e556–e561
Busin M, Scorcia V, Patel AK et al (2011) Donor tissue preparation for Descemet membrane endothelial keratoplasty. Br J Ophthalmol 95(8):1172–1173 (author reply 1173)
Dapena I, Ham L, Melles GRJ (2009) Endothelial keratoplasty: DSEK/DSAEK or DMEK—the thinner the better? Curr Opin Ophthalmol 20(4):299–307
Kitzmann AS, Goins KM, Reed C et al (2008) Eye bank survey of surgeons using precut donor tissue for descemet stripping automated endothelial keratoplasty. Cornea 27(6):634–639
Krabcova I, Studeny P, Jirsova K (2011) Endothelial cell density before and after the preparation of corneal lamellae for Descemet membrane endothelial keratoplasty with a stromal rim. Cornea 30(12):1436–1441
Krabcova I, Studeny P, Jirsova K (2013) Endothelial quality of pre-cut posterior corneal lamellae for Descemet membrane endothelial keratoplasty with a stromal rim (DMEK-S): two-year outcome of manual preparation in an ocular tissue bank. Cell Tissue Bank 14(2):325–331
Kruse FE, Schrehardt US, Tourtas T (2014) Optimizing outcomes with Descemet’s membrane endothelial keratoplasty. Curr Opin Ophthalmol 25(4):325–334
Lie JT, Birbal R, Ham L et al (2008) Donor tissue preparation for Descemet membrane endothelial keratoplasty. J Cataract Refract Surg 34(9):1578–1583
Lie JT, Groeneveld-van Beek EA, Ham L et al (2010) More efficient use of donor corneal tissue with Descemet membrane endothelial keratoplasty (DMEK): two lamellar keratoplasty procedures with one donor cornea. Br J Ophthalmol 94(9):1265–1266
Melles GRJ (2006) Posterior lamellar keratoplasty: DLEK to DSEK to DMEK. Cornea 25(8):879–881
Muraine M (2008) Endothelial keratoplasty. J Fr Ophtalmol 31(9):907–920
Muraine M, Gueudry J, He Z et al (2013) Novel technique for the preparation of corneal grafts for descemet membrane endothelial keratoplasty. Am J Ophthalmol 156(5):851–859
Price MO, Giebel AW, Fairchild KM et al (2009) Descemet’s membrane endothelial keratoplasty: prospective multicenter study of visual and refractive outcomes and endothelial survival. Ophthalmology 116(12):2361–2368
Rauen MP, Goins KM, Sutphin JE et al (2012) Impact of eye bank lamellar tissue cutting for endothelial keratoplasty on bacterial and fungal corneoscleral donor rim cultures after corneal transplantation. Cornea 31(4):376–379
Rudolph M, Laaser K, Bachmann BO et al (2012) Corneal higher-order aberrations after Descemet’s membrane endothelial keratoplasty. Ophthalmology 119(3):528–535
Schlötzer-Schrehardt U, Bachmann BO, Tourtas T et al (2013) Reproducibility of graft preparations in Descemet’s membrane endothelial keratoplasty. Ophthalmology 120(9):1769–1777
Tenkman LR, Price FW, Price MO (2014) Descemet membrane endothelial keratoplasty donor preparation: navigating challenges and improving efficiency. Cornea 33(3):319–325
Terry MA, Shamie N, Chen ES et al (2009) Precut tissue for Descemet’s stripping automated endothelial keratoplasty: vision, astigmatism, and endothelial survival. Ophthalmology 116(2):248–256
Thuret G, Manissolle C, Campos-Guyotat L et al (2005) Animal compound-free medium and poloxamer for human corneal organ culture and deswelling. Invest Ophthalmol Vis Sci 46(3):816–822
Venzano D, Pagani P, Randazzo N et al (2010) Descemet membrane air-bubble separation in donor corneas. J Cataract Refract Surg 36(12):2022–2027
Yamazoe K, Shinozaki N, Shimazaki J (2013) Influence of the precutting and overseas transportation of corneal grafts for Descemet stripping automated endothelial keratoplasty on donor endothelial cell loss. Cornea 32(6):741–744
Yoeruek E, Hofmann J, Bartz-Schmidt K-U (2013) Comparison of swollen and dextran deswollen organ-cultured corneas for Descemet membrane dissection preparation: histological and ultrastructural findings. Invest Ophthalmol Vis Sci 54(13):8036–8040
Zhu Z, Rife L, Yiu S et al (2006) Technique for preparation of the corneal endothelium-Descemet membrane complex for transplantation. Cornea 25(6):705–708
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Viridiana Kocaba and Celine Auxenfans are co-authors.
Rights and permissions
About this article
Cite this article
Marty, AS., Burillon, C., Desanlis, A. et al. Validation of an endothelial roll preparation for Descemet Membrane Endothelial Keratoplasty by a cornea bank using “no touch” dissection technique. Cell Tissue Bank 17, 225–232 (2016). https://doi.org/10.1007/s10561-016-9544-y
Received:
Accepted:
Published:
Issue Date: