Real-life evaluation of a human immunodeficiency virus screening algorithm using a single combined p24 antigen–antibody assay

  • Article
  • Published:
European Journal of Clinical Microbiology & Infectious Diseases Aims and scope Submit manuscript

Abstract

Since May 2010, human immunodeficiency virus (HIV) screening in France has been performed using a single combined fourth-generation assay. One of our major concerns is to verify that this screening strategy is able to diagnose HIV primary infection as soon as possible. Thus, the sensitivity and specificity of this strategy were evaluated on 49,623 serum samples, including 29 primary infections, received for routine HIV testing between September 2010 and November 2011. Specimens were screened using the Enzygnost HIV Integral II enzyme-linkedimmunosorbent assay (ELISA) kit. All positive sera, according to the manufacturer’s recommendations [signal-to-cutoff ratio (S/CO) ≥ 1] were retested using the Architect HIV Ag/Ab Combo. Moreover, we defined a grey zone (0.5 < S/CO < 1) and sera within this grey zone were retested using the VIDAS HIV DUO Ultra test and HIV-1 RNA was checked by the Abbott RealTime PCR kit. Screening tests were positive for all primary infections. All samples within the grey zone proved VIDAS HIV DUO Ultra and HIV-1 RNA negative. Overall, the ELISA test sensitivity and specificity were 100 and 99.79 %, respectively. The false-positive rate was higher when S/CO was in the low range (1 to 5). Adding a second screening test for positive sera reduced the false-positive rate from 0.20 to 0.02 %. HIV screening with a single combined assay did not miss any documented primary infection during this evaluation period, even without extending the positivity zone.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Brust S, Duttmann H, Feldner J, Gürtler L, Thorstensson R, Simon F (2000) Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test. J Virol Methods 90(2):153–165

    Article  PubMed  CAS  Google Scholar 

  2. Gürtler L, Mühlbacher A, Michl U, Hofmann H, Paggi GG, Bossi V et al (1998) Reduction of the diagnostic window with a new combined p24 antigen and human immunodeficiency virus antibody screening assay. J Virol Methods 75(1):27–38

    Article  PubMed  Google Scholar 

  3. Ly TD, Edlinger C, Vabret A (2000) Contribution of combined detection assays of p24 antigen and anti-human immunodeficiency virus (HIV) antibodies in diagnosis of primary HIV infection by routine testing. J Clin Microbiol 38(6):2459–2461

    PubMed  CAS  Google Scholar 

  4. Ly TD, Laperche S, Couroucé AM (2001) Early detection of human immunodeficiency virus infection using third- and fourth-generation screening assays. Eur J Clin Microbiol Infect Dis 20(2):104–110

    PubMed  CAS  Google Scholar 

  5. Saville RD, Constantine NT, Cleghorn FR, Jack N, Bartholomew C, Edwards J et al (2001) Fourth-generation enzyme-linked immunosorbent assay for the simultaneous detection of human immunodeficiency virus antigen and antibody. J Clin Microbiol 39(7):2518–2524

    Article  PubMed  CAS  Google Scholar 

  6. van Binsbergen J, Siebelink A, Jacobs A, Keur W, Bruynis F, van de Graaf M et al (1999) Improved performance of seroconversion with a 4th generation HIV antigen/antibody assay. J Virol Methods 82(1):77–84

    Article  PubMed  Google Scholar 

  7. Weber B, Fall EH, Berger A, Doerr HW (1998) Reduction of diagnostic window by new fourth-generation human immunodeficiency virus screening assays. J Clin Microbiol 36(8):2235–2239

    PubMed  CAS  Google Scholar 

  8. Costagliola D, Damond F, Palmer P, Rouzioux C, Brun-Vezinet F (2008) One or two enzyme-linked immunosorbent assay tests on the first serum sample for initial diagnosis of HIV-1 infection? AIDS 22(15):2042–2044

    Article  PubMed  CAS  Google Scholar 

  9. Haute Autorité de Santé (HAS) (2008) Dépistage de l’infection par le VIH en France: stratégies et dispositif de dépistage. http://www.has-sante.fr/portail/jcms/c_866949. Accessed October 2008

  10. Journal Officiel de la République Française (JORF) (2010) Arrêté du 28 mai 2010 fixant les conditions de réalisation du diagnostic biologique de l’infection à virus de l’immunodéficience humaine (VIH 1 et 2) et les conditions de réalisation du test rapide d’orientation diagnostique dans les situations d’urgence. http://www.legifrance.gouv.fr. Accessed 28 May 2010

  11. Meier T, Knoll E, Henkes M, Enders G, Braun R (2001) Evidence for a diagnostic window in fourth generation assays for HIV. J Clin Virol 23(1–2):113–116

    Article  PubMed  CAS  Google Scholar 

  12. Speers D, Phillips P, Dyer J (2005) Combination assay detecting both human immunodeficiency virus (HIV) p24 antigen and anti-HIV antibodies opens a second diagnostic window. J Clin Microbiol 43(10):5397–5399

    Article  PubMed  CAS  Google Scholar 

  13. Niederhauser C, Ströhle A, Stolz M, Müller F, Tinguely C (2009) The risk of a second diagnostic window with 4th generation HIV assays: two cases. J Clin Virol 45(4):367–369

    Article  PubMed  CAS  Google Scholar 

  14. Laperche S, Ly TD (2009) Performance dans la détection de l’antigène p24 avec les tests combinés VIH en 2009. Journées Internationales de Biologie (JIB) 2009. http://www.jib-sdbio.fr. Accessed 5 November 2009

  15. Miedouge M, Grèze M, Bailly A, Izopet J (2011) Analytical sensitivity of four HIV combined antigen/antibody assays using the p24 WHO standard. J Clin Virol 50(1):57–60

    Article  PubMed  CAS  Google Scholar 

  16. Ly TD, Ebel A, Faucher V, Fihman V, Laperche S (2007) Could the new HIV combined p24 antigen and antibody assays replace p24 antigen specific assays? J Virol Methods 143(1):86–94

    Article  PubMed  CAS  Google Scholar 

  17. Ly TD, Laperche S, Brennan C, Vallari A, Ebel A, Hunt J et al (2004) Evaluation of the sensitivity and specificity of six HIV combined p24 antigen and antibody assays. J Virol Methods 122(2):185–194

    Article  PubMed  CAS  Google Scholar 

  18. Yeni P (2010) Prise en charge médicale des personnes infectées par le VIH. Rapport 2010. Recommandations du groupe d’experts, Paris, France. Ministère en charge de la santé. http://www.sante.gouv.fr/. Accessed July 2010

  19. Weber B, Berger A, Rabenau H, Doerr HW (2002) Evaluation of a new combined antigen and antibody human immunodeficiency virus screening assay, VIDAS HIV DUO Ultra. J Clin Microbiol 40(4):1420–1426

    Article  PubMed  CAS  Google Scholar 

  20. Institut de Veille Sanitaire (InVS) (2011) Données épidémiologiques sur l’infection à VIH et les IST. http://www.invs.sante.fr/Espace-presse/Dossiers-de-presse. Accessed 1 December 2011

  21. Kim S, Lee J-H, Choi JY, Kim JM, Kim H-S (2010) False-positive rate of a “fourth-generation” HIV antigen/antibody combination assay in an area of low HIV prevalence. Clin Vaccine Immunol 17(10):1642–1644

    Article  PubMed  CAS  Google Scholar 

  22. Shima-Sano T, Yamada R, Sekita K, Hankins RW, Hori H, Seto H et al (2010) A human immunodeficiency virus screening algorithm to address the high rate of false-positive results in pregnant women in Japan. PLoS One 5(2):e9382

    Article  PubMed  Google Scholar 

  23. Ly TD, Plantier JC, Leballais L, Gonzalo S, Lemée V, Laperche S (2012) The variable sensitivity of HIV Ag/Ab combination assays in the detection of p24Ag according to genotype could compromise the diagnosis of early HIV infection. J Clin Virol 55(2):121–127

    Article  PubMed  CAS  Google Scholar 

  24. Yeni P (2008) Prise en charge médicale des personnes infectées par le VIH. Rapport 2008. Recommandations du groupe d’experts, Paris, France. Ministère en charge de la santé. http://www.sante.gouv.fr/. Accessed July 2008

  25. Prada N, Davis B, Jean-Pierre P, La Roche M, Duh F-M, Carrington M et al (2008) Drug-susceptible HIV-1 infection despite intermittent fixed-dose combination tenofovir/emtricitabine as prophylaxis is associated with low-level viremia, delayed seroconversion, and an attenuated clinical course. J Acquir Immune Defic Syndr 49(2):117–122

    Article  PubMed  CAS  Google Scholar 

  26. Long EF (2011) HIV screening via fourth-generation immunoassay or nucleic acid amplification test in the United States: a cost-effectiveness analysis. PLoS One 6(11):e27625

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgements

The authors would like to thank all the virology laboratory staff of the Croix-Rousse Hospital, Lyon, France, especially the serological staff for their helpful participation and dedication to this work.

The study was supported by Agence Nationale de Recherche sur le Sida et les Hépatites (ANRS) and the Hospices Civils de Lyon.

Conflict of interest

The authors declare they have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. André.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fanmi, A.N., Ramière, C., Tardy, J.C. et al. Real-life evaluation of a human immunodeficiency virus screening algorithm using a single combined p24 antigen–antibody assay. Eur J Clin Microbiol Infect Dis 32, 425–430 (2013). https://doi.org/10.1007/s10096-012-1760-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10096-012-1760-1

Keywords

Navigation