Abstract
A high-accuracy exact-matching isotope dilution mass spectrometry (IDMS) method for 19-norandrosterone (19-NA) in human urine was developed at NMIA for the certification of a freeze-dried human urine reference material (CRM NMIA MX002). The method utilised GC/HRMS analysis following hydrolysis, solvent extraction, HPLC fractionation and derivatisation. The method development included investigation of all potential analytical biases for the different stages of the method and included development of a confirmatory LC/MS/MS method. The measurement uncertainty of the reference method was rigorously investigated with the achieved expanded uncertainty being less than 4% at the 95% level of confidence. The method was used in the Comité Consultatif pour la Quantité de Matière (CCQM) pilot study CCQM-P68 which was an interlaboratory intercomparison for the analysis of 19-NA in human urine in which four national metrology institutes (NMIs) participated in. The agreement in the results from the NMIA method with those from the other NMIs was excellent.
References
WADA Technical Document—TD2004NA Reporting Norandrosterone Findings, WADA Laboratory Committee, 13 August 2004, http://www.wada-ama.org
Mackay LG, Burke D, Liu FH, Sousou N, Cuthbertson J, Vamathevan VV, Myors RB (2006) In: Schänzer W, Geyer H, Gotzmann A, Mareck U (eds) Recent advances in doping analysis, vol 14. Sportverlag Strauss, Köln, pp 203–211
Mackay LG, Burke D, Liu FH, Sousou N, Cuthbertson J (2006) In: Schänzer W, Geyer H, Gotzmann A, Mareck U (eds) Recent advances in doping analysis, vol 14. Sportverlag Strauss, Köln, pp 219–228
De Bièvre P, Peiser HS (1997) Fresenius J Anal Chem 359:523–525
Mackay LG, Burke D, Welch MJ, Tai S, Mussell C, O’Connor G, Sin D, Wing WC (2007) Accred Qual Assur. doi:10.1007/s00769-007-0287-0
Mackay LG, Taylor CP, Myors RB, Hearn R, King B (2003) Accred Qual Assur 8:191–193
Henrion A (1994) Fresenius J Anal Chem 350:657–658
Schanzer W, Donike M (1993) Anal Chim Acta 275:23–48
ISO Guide to the Expression of Uncertainty in Measurement (1995) International Organization for Standardization, Geneva, Switzerland
Acknowledgments
The authors are highly grateful to the World Anti-Doping Agency (WADA) and the Australian Government’s Anti-Doping Research Program for their financial support for this work. The authors would also like to thank the German Sport University, Cologne, for providing, via WAADS, a solution of the D4-19-NAG internal standard.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mackay, L.G., Burke, D., Liu, FH. et al. A high-accuracy method of analysis of 19-norandrosterone in human urine as utilised for the international laboratory intercomparison CCQM-P68. Accred Qual Assur 12, 475–482 (2007). https://doi.org/10.1007/s00769-007-0288-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00769-007-0288-z