Skip to main content
Log in

Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

  • Technical Note
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

Background

Insertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.

Methodology

We describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.

Results

Successful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.

Conclusion

We conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Shu C, Luo MY, Li QM, Li M, Wang T, He H. Early results of left carotid chimney technique in endovascular repair of acute non-a-non-B aortic dissections. J Endovasc Ther. 2011;18(4):477–84.

    Article  PubMed  Google Scholar 

  2. Zhu Y, Guo W, Liu X, Jia X, Xiong J, Wang L. The single-centre experience of the supra-arch chimney technique in endovascular repair of type B aortic dissections. Eur J Vasc Endovasc Surg. 2013;45(6):633–8.

    Article  CAS  PubMed  Google Scholar 

  3. Cuellar H, Guimaraens L, Ambekar S, Vivas E, Theron J. Angioseal as a hemostatic device for direct carotid puncture during endovascular procedures. Interv Neuroradiol. 2015;21(2):273–6.

    Article  PubMed  PubMed Central  Google Scholar 

  4. De Rango P, Cao P, Ferrer C, Simonte G, Coscarella C, Cieri E, et al. Aortic arch debranching and thoracic endovascular repair. J Vasc Surg. 2014;59(1):107–14.

    Article  PubMed  Google Scholar 

  5. Guilbert MC, Elkouri S, Bracco D, Corriveau MM, Beaudoin N, Dubois MJ, et al. Arterial trauma during central venous catheter insertion: case series, review and proposed algorithm. J Vasc Surg. 2008;48(4):918–25 discussion 925.

    Article  PubMed  Google Scholar 

  6. Berlet MH, Steffen D, Shaughness G, Hanner J. Closure using a surgical closure device of inadvertent subclavian artery punctures during central venous catheter placement. Cardiovasc Intervent Radiol. 2001;24(2):122–4.

    Article  CAS  PubMed  Google Scholar 

  7. Pua U, Tan GW, Punamiya S. Use of starclose device under ultrasound guidance in inadvertent carotid artery puncture. J Vasc Interv Radiol. 2015;26(9):1410–2.

    Article  PubMed  Google Scholar 

  8. Blanc R, Piotin M, Mounayer C, Spelle L, Moret J. Direct cervical arterial access for intracranial endovascular treatment. Neuroradiology. 2006;48(12):925–9.

    Article  CAS  PubMed  Google Scholar 

  9. Nii K, Kazekawa K, Onizuka M, Aikawa H, Tsutsumi M, Tomokiyo M, et al. Direct carotid puncture for the endovascular treatment of anterior circulation aneurysms. AJNR Am J Neuroradiol. 2006;27(7):1502–4.

    CAS  PubMed  Google Scholar 

  10. Blanc R, Mounayer C, Piotin M, Sadik JC, Spelle L, Moret J. Hemostatic closure device after carotid puncture for stent and coil placement in an intracranial aneurysm: technical note. AJNR Am J Neuroradiol. 2002;23(6):978–81.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Uei Pua.

Ethics declarations

Conflict of interest

The authors have no conflict of interest to be disclosed.

Statement of human and animal rights

This article does not contain any studies with human participants or animals performed by any of the authors.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chan, G., Quek, L.H.H., Tan, G.L.W. et al. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair. Cardiovasc Intervent Radiol 39, 1036–1039 (2016). https://doi.org/10.1007/s00270-016-1294-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-016-1294-5

Keywords

Navigation