Abstract
Background
The perforator-based flap is one of the most common and frequently used options for soft tissue reconstruction on extremities to remedy small to medium-size defects. A Doppler probe has been used to identify these perforators for the designing of the flap base, axis and dimensions. The reliability of the handheld Doppler was assessed for its sensitivity and positive predictive values.
Methods
A prospective study on upper and lower extremities was designed, and 14 volunteers were selected for the study. A handheld Doppler with 8- and 10-MHz probes was used, and the volunteers were subsequently scanned using a color duplex with a linear-array probe of 7 and 10 MHz. A total of 94 perforators were identified on the back of the hand, wrist, and distal 24 cm of the leg.
Results
The 49 perforators marked on 10 legs produced 40 correct, 3 false-positive, and 6 false-negative results. The 33 distal intermetacarpal perforators marked on the back of 11 hands yielded 26 correct, 5 false-positive, and 2 false-negative results. The 12 dorsal carpal arch perforators marked gave 6 correct and 6 false-positive results.
Conclusion
Unidirectional flowmetry using a handheld Doppler is a practical and reliable method for identifying skin perforators. It can be used to plan and design a flap for soft tissue defect reconstruction of extremities in selected cases. The reliability of its use is size dependent, and vessels with a smaller diameter showed unacceptably high false-positive results.
Similar content being viewed by others
References
Taylor GI, M Doyle, McCarten G (1990) The Doppler probe for planning flaps: Anatomical study and clinical applications. Br J Plast Surg 43:1–16
Khan UD, McArthur P, Miller JG Extended distally based perforator flap. Autumn meeting of the British Society for Surgery of the Hand and the Swiss Society of Surgery of the Hand at Blackpool, 27–29 October 1999
Spyriounis PK (2006) The extended approach to the vascular pedicle of the ALT-thigh perforator flap: Anatomical and clinical study. Plast Reconstr Surg 117:997–1001
Dujon DG, Khan UD, Aslam S (1997) Bipedicle flaps: Simple solutions for difficult problems in the extremities. Br J Plast Surg 50:641–645
Bisson M, Spyriounis P, Miller J (2004) Perforator-based flaps in distal upper and lower extremity defects. Eur J Plast Surg 25:86–90
Blondeel PN, Beyens G, Verhaeghe R, Landuyt VK, Tonnard P, Monstrey SJ, Matton G (1998) Doppler flowmetry in the planning of perforator flaps. Br J Plast Surg 51:202–209
Koshima I, Soeda S (1989) Inferior epigastric artery skin flap without rectus abdominis muscle. Br J Plast Surg 42:645–648
Amarante J, Martins A, Reis J (1988) A distally based median plantar flap. Ann Plast Surg 20:468
Costa H, Soutar DS (1988) The distally based island posterior interosseous flap. Br J Plast Surg 41:221
Breakwell LM, Khan UD, Miller JG, Spyriounis P Perforator-based flaps. Winter Meeting, British Association of Plastic Surgeons, 2–4 Dec 1998, BOA, Prontaprint, Darlington, UK, p. 31
Earley MJ, Milner RH (1987) Dorsal metacarpal flaps. Br J Plast Surg 40:333–341
Salmon M (1988) Arteries of the skin. Taylor GI, Tempest, MN, Churchill Livingstone, London, p 29–34
Quaba AA, Davison PM (1990) The distally based dorsal hand flap. Br J Plast Surg 43:28–39
Komuro Y, Iwata H, Inoue M, Yanai A (2002) Versatility of scanning laser Doppler imaging to detect cutaneous perforators. Ann Plast Surg 48:613–616
Khan UD, McArthur P, Miller JG, Shariff S, Ashurst H Reliability of handheld Doppler in planning local skin flaps. Third International Course on Perforator Flaps at Munich, Germany, 12–14 November 1999
Taylor IG, Pan WR (1998) Angiosomes of the leg: Anatomic study and clinical implications. Plast Reconstr Surg 102:599–615
Acknowledgments
1) I thank the Medical Physics Department of Northern General Hospital Sheffield, England, for its help, and Dr. A. Omair, Associate Professor of Community Medicine at Ziauddin Medical University, Karachi, Pakistan, for the data analysis.
Author information
Authors and Affiliations
Corresponding author
Additional information
Presented at the Third International Course on Perforator Flaps, Munich, Germany, 12–14 November 1999.
Rights and permissions
About this article
Cite this article
Khan, U.D., Miller, J.G. Reliability of Handheld Doppler in Planning Local Perforator–Based Flaps for Extremities. Aesth Plast Surg 31, 521–525 (2007). https://doi.org/10.1007/s00266-007-0072-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00266-007-0072-9