Skip to main content

Advertisement

Log in

Total hip replacement arthroplasty with Mallory-Head system—minimum ten-year follow-up results

  • Original Paper
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract

Purpose

The purpose of this study was to assess the clinical and radiographic results of a total hip arthroplasty with the double tapered Mallory-Head system.

Methods

The clinical and radiographic results of a consecutive series of 81 total hip replacements in 75 patients were reviewed 10–15 years (average 11.4 years) postoperatively. The patients’ underlying conditions were avascular necrosis in 46 hips (57 %), osteoarthritis in 12 hips (15 %), RA in nine hips (11 %), and others. Clinical results were evaluated based on the modified Harris hip score and modified Merle d’Aubigné-Postel score. A radiographic analysis was performed.

Results

The average modified Harris hip score improved from a preoperative score of 56 points to a postoperative 92 points. The average modified Merle d’Aubigné-Postel score was 15 points at the latest follow up, and 55 hips (68 %) were classified as the clinical grades of excellent or good results. One acetabular component was revised because of loosening, and one was revised for recurrent dislocation.

Conclusion

The clinical and radiological evaluations of the total hip replacements using the Mallory-Head system showed good results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Ritter MA, Fechtman RW (1988) Distal cortical hypertrophy following total hip arthroplasty. J Arthroplasty 3:117–121

    Article  PubMed  CAS  Google Scholar 

  2. Sakalkale DP, Eng K, Hozack WJ, Rothman RH (1999) Minimum 10-year results of a tapered cementless hip replacement. Clin Orthop Relat Res 362:138–144

    Article  PubMed  Google Scholar 

  3. Nakoshi Y, Hasegawa M, Sudo A, Uchida A (2009) A long-term follow-up study of the cementless THA with anatomic stem/HGPII cup with 22-mm head. Int Orthop 33:381–385. doi:10.1007/s00264-007-0505-8

    Article  PubMed  Google Scholar 

  4. McLaughlin JR, Lee KR (1997) Total hip arthroplasty with an uncemented femoral component. Excellent results at ten-year follow-up. J Bone Joint Surg Br 79:900–907

    Article  PubMed  CAS  Google Scholar 

  5. Ovre S, Sandvik L, Madsen JE, Roise O (2007) Modification of the Harris Hip Score in acetabular fracture treatment. Injury 38:344–349. doi:10.1016/j.injury.2006.04.129

    Article  PubMed  Google Scholar 

  6. Matta JM, Mehne DK, Roffi R (1986) Fractures of the acetabulum. Early results of a prospective study. Clin Orthop Relat Res 205:241–250

    PubMed  Google Scholar 

  7. Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27

    PubMed  Google Scholar 

  8. DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32

    PubMed  Google Scholar 

  9. Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72:518–528

    PubMed  CAS  Google Scholar 

  10. Ragab AA, Kraay MJ, Goldberg VM (1999) Clinical and radiographic outcomes of total hip arthroplasty with insertion of an anatomically designed femoral component without cement for the treatment of primary osteoarthritis. A study with a minimum of six years of follow-up. J Bone Joint Surg Am 81:210–218

    PubMed  CAS  Google Scholar 

  11. Kim YH, Kim VE (1992) Results of the Harris-Galante cementless hip prosthesis. J Bone Joint Surg Br 74:83–87

    PubMed  CAS  Google Scholar 

  12. Maloney WJ, Jasty M, Harris WH, Galante JO, Callaghan JJ (1990) Endosteal erosion in association with stable uncemented femoral components. J Bone Joint Surg Am 72:1025–1034

    PubMed  CAS  Google Scholar 

  13. Niinimaki TJ, Puranen JP, Jalovaara PK (1995) Revision arthroplasty with an isoelastic uncemented femoral stem. Int Orthop 19:298–303

    Article  PubMed  CAS  Google Scholar 

  14. Bourne RB, Rorabeck CH, Burkart BC, Kirk PG (1994) Ingrowth surfaces. Plasma spray coating to titanium alloy hip replacements. Clin Orthop Relat Res 298:37–46

    PubMed  Google Scholar 

  15. Engh CA, Massin P, Suthers KE (1990) Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 257:107–128

    PubMed  Google Scholar 

  16. Haddad RJ Jr, Skalley TC, Cook SD, Brinker MR, Cheramie J, Meyer R, Missry J (1990) Clinical and roentgenographic evaluation of noncemented porous-coated anatomic medullary locking (AML) and porous-coated anatomic (PCA) total hip arthroplasties. Clin Orthop Relat Res 258:176–182

    PubMed  Google Scholar 

  17. Hedley AK, Gruen TA, Borden LS, Hungerford DS, Habermann E, Kenna RV (1987) Two-year follow-up of the PCA noncemented total hip replacement. Hip 1987:225–250

    Google Scholar 

  18. Jacobs JJ, Galante JO, Sumner DR (1992) Local response to biomaterials: bone loss in cementless femoral stems. Instr Course Lect 41:119–125

    PubMed  CAS  Google Scholar 

  19. Rosenberg A (1989) Cementless total hip arthroplasty: femoral remodeling and clinical experience. Orthopedics 12:1223–1233

    PubMed  CAS  Google Scholar 

  20. Heekin RD, Callaghan JJ, Hopkinson WJ, Savory CG, Xenos JS (1993) The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study. J Bone Joint Surg Am 75:77–91

    PubMed  CAS  Google Scholar 

  21. Dorr LD, Lewonowski K, Lucero M, Harris M, Wan Z (1997) Failure mechanisms of anatomic porous replacement I cementless total hip replacement. Clin Orthop Relat Res 334:157–167

    Article  PubMed  Google Scholar 

  22. Goetz DD, Smith EJ, Harris WH (1994) The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. A retrospective matched-pair series. J Bone Joint Surg Am 76:1121–1129

    PubMed  CAS  Google Scholar 

  23. Sanchez-Sotelo J, Lewallen DG, Harmsen WS, Harrington J, Cabanela ME (2004) Comparison of wear and osteolysis in hip replacement using two different coatings of the femoral stem. Int Orthop 28:206–210. doi:10.1007/s00264-004-0558-x

    Article  PubMed  Google Scholar 

  24. Schmalzried TP, Jasty M, Harris WH (1992) Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am 74:849–863

    PubMed  CAS  Google Scholar 

  25. Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC (1980) The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clin Orthop Relat Res 150:263–270

    PubMed  Google Scholar 

  26. Emerson RH Jr, Sanders SB, Head WC, Higgins L (1999) Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty. J Bone Joint Surg Am 81:1291–1298

    PubMed  Google Scholar 

  27. Santavirta S, Hoikka V, Eskola A, Konttinen YT, Paavilainen T, Tallroth K (1990) Aggressive granulomatous lesions in cementless total hip arthroplasty. J Bone Joint Surg Br 72:980–984

    PubMed  CAS  Google Scholar 

  28. Gosens T, van Langelaan EJ, Tonino AJ (2003) Cementless Mallory-Head HA-coated hip arthroplasty for osteoarthritis in hip dysplasia. J Arthroplasty 18:401–410

    Article  PubMed  CAS  Google Scholar 

  29. Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC (2001) Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty 16:49–54

    Article  PubMed  CAS  Google Scholar 

  30. Mulliken BD, Bourne RB, Rorabeck CH, Nayak N (1996) Results of the cementless Mallory-Head primary total hip arthroplasty: a 5 to 7 year review. Iowa Orthop J 16:20–34

    PubMed  CAS  Google Scholar 

  31. Park MS, Choi BW, Kim SJ, Park JH (2003) Plasma spray-coated Ti femoral component for cementless total hip arthroplasty. J Arthroplasty 18:626–630

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Juyoung Kim.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Song, JH., Kim, DH. & Kim, J. Total hip replacement arthroplasty with Mallory-Head system—minimum ten-year follow-up results. International Orthopaedics (SICOT) 36, 2055–2059 (2012). https://doi.org/10.1007/s00264-012-1627-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-012-1627-1

Keywords

Navigation