Abstract
The aim of this investigation was to evaluate the role of ultrasonography in avoiding cranial misplacement of the tracheostomy tube and tracheal ring fractures during percutaneous dilatational tracheostomy (PDT). The tracheas of 26 consecutive ICU patients who had undergone PDT but who later died were removed en bloc at autopsy. The tracheas were opened along the membranous portion and the condition of tracheal rings and the site of tracheostomy macroscopically evaluated. The patients were divided in two groups: group A with 15 patients who underwent "blind" PDT and group B with 11 patients who underwent ultrasound-guided PDT. In five (33%) patients from group A, autopsy revealed that the tracheostomy tube was placed between the cricoid cartilage and the first tracheal ring (cranial misplacement) and in six (43%) patients a fracture of one tracheal ring was found. Cranial misplacement of the tracheostomy tube in patients from group B was not found (P <0.05) and four (36%) patients had a broken tracheal ring (P=NS). The authors maintain that by using ultrasound-guided PDT cranial misplacement of the tracheostomy tube may be entirely avoided.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Final revision received: 19 May 2000
Electronic Publication
Rights and permissions
About this article
Cite this article
Šustić, A., Kovač, D., Žgaljardić, Z. et al. Ultrasound-guided percutaneous dilatational tracheostomy: a safe method to avoid cranial misplacement of the tracheostomy tube. Intensive Care Med 26, 1379–1381 (2000). https://doi.org/10.1007/s001340000589
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s001340000589