Abstract
Heat insulating and acoustic absorbing materials were endued with fireproof performance and subjected to quantitative evaluations assuming a variety of uses and situations. Fireproofing was performed by spraying an aqueous solution of flame retardants on raw materials (wood shavings, kenaf bast fibers, and core-sheath-type fibers) during the fiber spreading and mixing step. It was possible to treat the materials homogeneously and without increasing manufacturing workload. Flame retardancy was evaluated using vertical flame testing, horizontal flame testing, the 45° Meckel’s Burner method, and a cone calorimetry method in accordance with UL94, JIS D 1201, JIS L 1091, and JIS A 9521, respectively. It was possible to achieve results that satisfied each of these standards, along with quantifying the relations between treatment conditions and performance.
Similar content being viewed by others
References
Fukuta S, Nishizawa M, Ota Y (2010a) Deep-thin-drilling process for wood and its application for fire-retardant treatment. ISSN 1347-9296 9:18–21
Fukuta S, Nishizawa M, Ota Y, Takasu Y, Mori T, Yamasaki M, Sasaki Y (2010b) Development of low-density wooden molding mat using bicomponent fibers. For Prod J 60(7/8):575–581
Fukuta S, Nishizawa M, Takasu Y, Ota Y, Mori T, Yamasaki M, Sasaki Y (2012) Sound absorption and form retention of newly developed heat-insulating/acoustic material. Eur J Wood Prod 70:697–704
Grohe B (2003) Fungus and fire resistance of insulation mats based on water glass bonded non-textile flax fibres. Holz Roh-Werkst 61:475–476
JIS L 1091 (1999) Testing methods for flammability of textiles. Japan Standard Association (JIS) Tokyo
JIS D 1201 (1998) Road vehicles, and tractors and machinery for agriculture and forestry—determination of burning behaviour of interior materials. Japan Standard Association (JIS) Tokyo
JIS A 9521 (2011) Man made mineral wool thermal insulation materials for dwellings. Japan Standard Association (JIS) Tokyo
Pedieu R, Koubaa A, Riedl B, Wang X, Deng J (2012) Fire-retardant properties of wood particleboards treated with boric acid. Eur J Wood Prod 70:191–197
Taniuchi H, Sekino N, Yamauchi G (2008) Fire safety of wooden walls filled with wood shaving insulation panels—its heat shielding effect and structural safety compared to fiberglass-filled walls. Wood Preserv 34(2):60–68
UL 94 (2013) Standard for tests for flammability of plastic materials for parts in devices and appliances. Underwriters Laboratories (UL) Illinois
Acknowledgments
We extend our thanks to the LIXIL JS Foundation for their assistance in carrying out this study.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Fukuta, S., Nomura, M., Nishizawa, M. et al. Evaluation and fireproofing treatment of wooden heat-insulating/acoustic absorbing materials. Eur. J. Wood Prod. 72, 713–720 (2014). https://doi.org/10.1007/s00107-014-0840-6
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00107-014-0840-6