A fast estimation of biochemical oxygen demand using microbial sensors

  • Environmental Microbiology
  • Short Contribution
  • Published:
Applied Microbiology and Biotechnology Aims and scope Submit manuscript

Summary

Microbial amperometric sensors for biochemical oxygen demand (BOD) determination using Bacillus subtilis or Trichosporon cutaneum cells immobilized in polyvinylalcohol have been developed. These sensors allow BOD measurements with very short response times (15–30s), a level of precision of ±5% and an operation stability of 30 days. A linear range was obtained for a B. subtilis-based sensor up to 20 mg/l BOD and for a T. cutaneum-based sensor up to 100 mg/l BOD using a glucose/glutamic acid standard.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  • APHA (1976) Standard methods for examination of water and waste water. American Public Health Association Inc., New York

    Google Scholar 

  • harita K, Otani Y, Hikuma M, Yasuda T (1985) BOD quick estimating system utilizing microbial electrode. Instrumental Control. Water, Waste Water Treatment Transport System. Proc IAWPRC Workshop 4:529–532

    Google Scholar 

  • Hikuma M, Suzuki H, Yasuda T, Karube I, Suzuki S (1979) Amperometric estimation of BOD by using living immobilized yeast. Eur J Appl Microbiol 8:289–297

    Google Scholar 

  • JIS (1974) Japanese Industrial Standard Committee, Testing methods for industrial waste water, JIS K 0102 Tokyo, p 33

  • Karube I, Matsunaga T, Mitsuda S, Suzuki S (1977) Microbial electrode BOD sensor. Biotechnol Bioeng 19:1535–1547

    Google Scholar 

  • Kawabata N, Nakamura N (1986) New BOD sensor utilizing a functional polymer which captures microorganisms alive. Abstracts of the International Symposium on New Sensors and Methods for Environmental characterization, Kyoto, Japan

  • Kulys J, Kadziauskiené K (1980) Yeast BOD sensor. Biotechnol Bioeng 22:221–226

    Google Scholar 

  • Lowden G (1981), Tests for assessing the oxygen demand of effluents. Water Res Top 1:142–151

    Google Scholar 

  • OECD (1981) Organization for Economic Cooperation and Development. Activated sludge, respiration inhibition test. OECD Guideline for Testing of Chemicals No. 209

  • Riedel K, Liebs P, Renneberg R (1985) An electrochemical method for determination of cell respiration. J Basic Microbiol 25:51–56

    Google Scholar 

  • Strand SE, Carlson DA (1984) Rapid BOD measurement for municipal waste water samples using a biofilm electrode. J Water Pollut Control Fed 56:464–467

    Google Scholar 

  • Zhang X, Wang Z, Jian H (1986) Microbial sensor for the BOD estimation (in Chinese) Huanjing Kexue Xuebao 6:184–192; cited in Chem Abstr, 105:158286 (1986)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Riedel, K., Renneberg, R., Kühn, M. et al. A fast estimation of biochemical oxygen demand using microbial sensors. Appl Microbiol Biotechnol 28, 316–318 (1988). https://doi.org/10.1007/BF00250463

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00250463

Keywords

Navigation