Most radiology departments have established quality assurance (QA) and quality control (QC) programs for conventional film-based image management systems. At many institutions, digital image management systems, or picture archiving and communication systems (PACS), are replacing part or all of the film management system. In these situations, it is important to control the quality of the digital images that are produced. The observed frequency of eight types of image-related errors occurring on an image viewing station located in a medical intensive care unit is reported. Images on the viewing station were checked for 12 consecutive weeks. Film images available in the radiology reading room and digital images on the viewing station were compared with a list of completed examinations produced by the radiological information system. Overall, 1,082 patient examinations were encountered. Seventy-six images (7.02% of all images) were observed with errors. In addition, four previously unencountered types of errors were observed in 11 images (1.01% of all images). The majority of the errors are attributed to interfaces either between information systems or between the PACS and the user. It is concluded that QA-QC procedures are necessary for PACS, and that good interfaces, both between information systems and between humans and computer systems, are essential for successful PACS implementations.
Article PDF
Similar content being viewed by others
References
Quality assurance for diagnostic imaging equipment: Recommendations of the National Council on Radiation Protection and Measurements Report 99. Bethesda, MD, National Council on Radiation Protection and Measurements (NCRP), 1988, p 4
Quality assurance for diagnostic imaging equipment: Recommendations of the National Council on Radiation Protection and Measurements Report 99. Bethesda, MD, National Council on Radiation Protection and Measurements (NCRP), 1988, p 22
Stewart BK, Massoth RJ, Thomas SR: Mini-PACS, in Hendee WR, Trueblood JH (eds): Digital Imaging: Medical Physics Monograph No. 22. Madison, WI, Medical Physics Publishing, 1993, pp 123–156
Ravin CE: Initial experience with automatic image transmission to an intensive care unit using picute archiving and communication system technology. J Digit Imaging 3:195–199, 1990
Witt RM, Cohen MD, Appledorn CR: Initial experience with a radiology imaging network to newborn and intensive care units. J Digit Imaging 4:39–42, 1991
DeSimone DN, Kundel HL, Arenson RL, et al: Effect of a digital imaging network on physician behavior in an intensive care unit. Radiology 169:41–44, 1988
Gillespy T, Staab EV, Lawrence E: Electronic imaging in a teaching hospital intensive care unit: Evaluation of the clinical review system. J Digit Imaging 3:124–128, 1990
Cho PS, Huang HK, Tillish J, et al: Clinical evaluation of a radiological picture archiving and communication system for coronary care unit. AJR 151:823–827, 1988
Parsons DM, Kim Y, Haynor DR: Quality-control of cathode-ray tube monitors for medical imaging using a simple photometer. J Digit Imaging 8:10–20, 1995
Halpern EJ: A test pattern for quality-control of laser scanner and charge-coupled-device film digitizers. J Digit Imaging 8:3–9, 1995
Marsh DM, Cooney P, Malone JF: An assessment of the variation in image quality with multiformat cameras. Radiat Protection Dosimetey 57:277–280, 1995
Freedman M, Steller D, Jafroudl H, Mun SK: Quality control of storage phosphor digital radiography systems. J Digit Imaging 8:67–74, 1995
Seibert JA, Barnes GT, Gould RG (eds): Specification, Acceptance Testing and Quality Control of Diagnostic X-Ray Imaging Equipment. Woodbury, MA, American Association of Physicists in Medicine, 1994
Roehrig H, Yu T, Krupinski E: Image quality control for digital mammographic systems: Initial experience and outlook. J Digit Imaging 8:52–67, 1995
Tucker DM, Barnes GT, Koehler RE: Picture archiving communication systems in the intensive care unit. Radiology 196:297–304, 1995
Wandtke JC: Bedside chest radiography. Radiology 190:1–10, 1994
David G, Gregory S: Adding a microcomputer barcode network to a minicomputer-based radiology information system. J Digit Imaging 3:31–33, 1990
Frank MS, Rowberg AH, Tecotzky R: Integrating a radiology information system with a commercially-available computed radiology apparatus: An example of an interactive gateway, in Boehme JM, Rowberg AH, Wolfman NT (eds): Computer Applications to Assist Radiology. Carlsbad, CA, Symposia Foundation, 1995, pp 587–591
Breant CM, Tiara RK, Huang HK: Interfacing aspects between the picture archiving and communication system, radiology information system, and hospital information system. J Digit Imaging 15:88–94, 1993
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Tucker, D.M., McEachern, M. Quality assurance and quality control of an intensive care unit picture archiving and communication system. J Digit Imaging 8, 162–167 (1995). https://doi.org/10.1007/BF03168715
Issue Date:
DOI: https://doi.org/10.1007/BF03168715