Abstract
Temperature-controlled measurements of the transverse relaxation time were conducted with the NMR-MOUSE (nuclear magnetic resonance mobile universal surface explorer) at 50°C to investigate the heterogeneity of rubber sheets induced by thermo-oxidative aging. With temperature stabilization the relative error ofT 2 decreased by a factor of 4 on the short time scale. Without temperature stabilization it may reach 30% in the long-time range because of temperature changes in the laboratory. Two different types of mobile temperature control units operating with the NMR-MOUSE are described. These temperature control units are small and portable like the NMR-MOUSE.
Similar content being viewed by others
References
Eidmann G., Salvelsberg R., Blümler P., Blümich B.: J. Magn. Reson. A122, 104–109 (1996)
Blümich B., Blümler P., Eidmann G., Guthausen A., Haken R., Schmitz U., Saito K., Zimmer G.: Magn. Reson. Imaging16, 479–484 (1998)
Anferova S., Anferov V., Adams M., Blümer P., Routley N., Hailu K., Kupferschläger K., Mallet M., Schroeder G., Sharma S., Blümich B.: Magn. Reson. Eng.15, 15–22 (2002)
Blümich B., Anferov V., Anferova S., Klein M., Fechete R., Adams M., Casanova F.: Magn. Reson. Eng.15, 255–261 (2002)
Herrmann V., Unseld K., Fuchs H.B., Blümich B.: Colloid Polym. Sci.280, 758–764 (2002)
Blümich B., Anferova S., Kremer K., Sharma S., Herrmann V., Segre A.: Spectroscopy18, 18–33 (2003)
CAL Controls Ltd, CAL 3200, Bury Mead Road, Hitchin, Herts, SG5 1RT, UK.
Litvinov V., De P.P. (eds.): Spectroscopy of Rubbers and Rubbery Materials, p. 360. Shawbury, UK: Rapra Technology 2002.