Skip to main content
Log in

Detection of venous air embolism by continuous intraarterial oxygen monitoring

  • Case Report
  • Published:
Journal of Clinical Monitoring Aims and scope Submit manuscript

Abstract

In a recent study, we compared a new intraarterial fiberoptic “optode” probe to continuously measure arterial oxygen and carbon dioxide tensions and pH with intermittently drawn blood samples in patients undergoing surgery. In one patient with a diagnosis of Arnold-Chiari type I malformation with outflow obstruction of the fourth ventricle, a major pulmonary air embolism occurred while the patient was undergoing suboccipital craniectomy and cervical laminectomy in the prone position. Three hours after the incision the optode-displayed oxygen tension decreased from a stable value of 225 ±8 mm Hg to 63 mm Hg over a 10-minute period. During the same interval, carbon dioxide tension increased and end-tidal carbon dioxide decreased; shortly thereafter, transcutaneous oxygen tension decreased also. Within 20 minutes after the inspired gas mixture was changed to 100% oxygen, the patient’s respiratory variables returned to near baseline. No further complications ensued. This is the first time continuously monitored arterial oxygen tension values during a pulmonary embolism have been reported. With further refinement, intraarterial optode probes will add another valuable method of detecting pulmonary air embolism.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Michenfelder JD, Terry HR, Davv EF, Miller RH. Air embolism during neurosurgery: a new method of treatment. Anesth Anaig 1966;45:390–394

    Google Scholar 

  2. Buchland RW, Manners JM. Venous air embolism during neurosurgery. Anaesthesia 1976;31:633–643

    Article  Google Scholar 

  3. Michenfelder JD, Martin JT, Altenberg BM, Rehden K. Air embolism during neurosurgery. JAMA 1969;208:1353–1358

    Article  PubMed  CAS  Google Scholar 

  4. Glenski JA, Cucchiara RF, Michenfelder JD. Transesophageal echocardiography and transcutaneous O2 and CO2 monitoring for detection of venous air embolism. Anesthesiology 1986;64:541–545

    PubMed  CAS  Google Scholar 

  5. Marshall WK, Bedford RF. Use of a pulmonary-artery catheter for detection and treatment of venous air embolism. Anesthesiology 1980;52:131–134

    Article  PubMed  CAS  Google Scholar 

  6. Maroon JC, Albin MS. Air embolism diagnosed by Doppler ultrasound. Anesth Analg 1974;53:399–402

    Article  PubMed  CAS  Google Scholar 

  7. Michenfelder JD, Miller RH, Gronert GA. Evaluation of an ultrasonic device (Doppler) for the diagnosis of venous air embolism. Anesthesiology 1972;36:164–167

    Article  PubMed  CAS  Google Scholar 

  8. Gildenberg PL, O’Brian PA, Britt WJ, Frost EA. The efficacy of Doppler monitoring for the detection of venous air embolism. J Neurosurgery 1981;54:75–78

    CAS  Google Scholar 

  9. Bethune RWM, Brechner VL. Detection of venous air embolism by carbon dioxide monitoring. Anesthesiology 1968;29:168

    Article  Google Scholar 

  10. Glenski JA, Cucchiara RF. Transcutaneous O2 and CO2 monitoring of neurosurgical patients: detection of air embolism. Anesthesiology 1986;64:546–550

    PubMed  CAS  Google Scholar 

  11. Matjasku MJ, Hollman J, Mackenzie CF. Venous air embolism, hypotension, and end-tidal nitrogen. Neurosurgery 1987;21:378–382

    Article  Google Scholar 

  12. Sato S, Tuya S, Ohira T, et al. Echocardiographic detection and treatment of intraoperative air embolism. J Neurosurg 1986;64:440–444

    Article  PubMed  CAS  Google Scholar 

  13. Furuya H, Suzuki T, Okamura F, et al. Detection of air embolism by transesophageal echocardiography. Anesthesiology 1983;58:124–129

    Article  PubMed  CAS  Google Scholar 

  14. Gibby GL, Ghani GA. Computer-assisted Doppler monitoring to enhance detection of air emboli. J Clin Monit 1988;4:64–73

    Article  PubMed  CAS  Google Scholar 

  15. Barker SJ, Tremper KK, Hyatt J, et al. Continuous fiberoptic arterial oxygen tension measurements in dogs. J Clin Monit 1987;3:48–52

    PubMed  CAS  Google Scholar 

  16. Sloan TB, Kimovec MA. Detection of venous air embolism by airway pressure monitoring. Anesthesiology 1986;64:645–647

    Article  PubMed  CAS  Google Scholar 

  17. Oyamu Y, Spencer MP. Cardiopulmonary effects of intravenous gas embolism; with special reference to fate of intravascular gas bubbles. Jpn Circ J 1971;35:1541–1549

    Google Scholar 

  18. Adornato DC, Gildenberg PL, Ferrario CM, et al. Pathophysiology of intravenous air embolism in dogs. Anesthesiology 1978;49:120–129

    Article  PubMed  CAS  Google Scholar 

  19. Wagner PD, Laravula RB, Goldzimmer E, et al. Distributions of ventilation-perfusion ratios in dogs with normal and abnormal lungs. J Appl Physiol 1975;38:1099–1109

    PubMed  CAS  Google Scholar 

  20. Verstappen FTJ, Bernards JA, Kreuzer F. Effects of pulmonary gas embolism on circulation and respiration in the dog. Intravenous origin of arterial hypoxemia during pulmonary gas embolism. Pflugers Arch 1977;370:71

    Article  PubMed  CAS  Google Scholar 

  21. Robin ED, Furkner CE, Bromberg PA, et al. Alveolar gas exchange in clinical pulmonary embolism. N Engl J Med 1960;262:283–287

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Greenblott, G., Barker, S.J., Tremper, K.K. et al. Detection of venous air embolism by continuous intraarterial oxygen monitoring. J Clin Monitor Comput 6, 53–56 (1990). https://doi.org/10.1007/BF02832181

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02832181

Key Words

Navigation