Abstract
Two methods, manual back-off and capacitor coupling (by cutting off the d.c. component) are usually used to measure a small transient signal superposed on a large electric current. The shortcomings of them are analysed and an automatic current back-off circuit with high accuracy is described in this paper. The response time of this circuit needed for compensating a sudden change in the large electric current is less than 50 microseconds. The described circuit can be used for the time scale from 1 microsecond per division upward on an oscilloscope. Mathematical analysis of the response time of the circuit is presented and a practical circuit is also given in detail.
Similar content being viewed by others
References
B. Chance, Rapid Flow Methods, Techniques of Chemistry, Vol. 6 (1974), p. 5, G. G. Hammes Ed., Wiley, New York.
G. G. Hammes, Temperature-Jump Methods, Techniques of Chemistry, Vol 6 (1974), p. 147, G. G. Hammes, Ed., Wiley, New York.
J. P. Keene, The Technique of Pulse Radiolysis by Optical Absorption, Pulse Radiolysis, 1965, p. 1, M. Ebert et al. Ed., Academic Press, London.
G. Porter, Flash Photolysis, Techniques of Chemistry, Vol 6 (1974), p. 367, G. G. Hammes Ed., Wiley, New York.
J. P. Keene,Quaderni dell’Area di Ricerca dell Emilia-Romagna,1 (1972), 63.
J. P. Keene and C. Bell,Int. J. Radiat. Phys. Chem.,5 (1973), 463.
Author information
Authors and Affiliations
About this article
Cite this article
Dejiang, T., Xinyuan, L., Chunzhang, C. et al. The measurement of a small transient signal superposed on a large electric current. J. of Electron. (China) 1, 28–35 (1984). https://doi.org/10.1007/BF02824096
Issue Date:
DOI: https://doi.org/10.1007/BF02824096