Skip to main content
Log in

An exact analysis for a solute transport, due to simultaneous dialysis and ultrafiltration, in a hollow-fibre artificial kidney

  • Published:
Bulletin of Mathematical Biology Aims and scope Submit manuscript

Abstract

Transport of a uremic solute effected by a combined dialysis and ultrafiltration procedure in a hollow-fibre artificial kidney, is investigated theoretically under standard assumptions. An exact analytical solution for the concentration profile in a blood channel is obtained by using the method of separation of variables. The necessary requirement that the solution must tend to that of pure dialysis, in the limit ultrafiltration tending to zero, is fulfilled. Exact analytical expressions are derived for the eigenconstants of the solution. In using the solution, the solute clearance is emphasized. Diffusive and ultrafiltration components of the solute clearance are defined and studied. The combined procedure is examined for middle versus small molecules and for polyacrylonitrile versus cuprophan hollow-fibres.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literature

  • Davis, H. R. and G. V. Parkinson. 1970. “Mass Transfer from Small Capillaries with Wall Resistance in the Laminar Flow Regime”.Appl. Sci. Res. 22, 20–30.

    MATH  Google Scholar 

  • Gupta, B. B. and M. Y. Jaffrin. 1984. “In Vitro Study of Combined Convection Diffusion Mass Transfer in Hemodialysers”.Int. J. artif. Organs 2, 263–268.

    Google Scholar 

  • Henderson, L. W. 1978. “Current Status of Hemofiltration”.Artif. Organs 2, 120–124.

    Google Scholar 

  • Jagannathan, R. and U. R. Shettigar. 1977. “Analysis of a Tubular Hemodialyzer-effect of Ultrafiltration and Dialysate Concentration”.Med. Biol. Eng. Comput. 15, 500–511.

    Article  Google Scholar 

  • Leber, H. W., V. Wizemann, G. Goubeaud, P. Rauear and G. Schutterle. 1978. “Hemodiafiltration: a New Alternative to Hemofiltration and Conventional Hemodialysis”.Artif. Organs,2, 150–153.

    Article  Google Scholar 

  • Sigdell, J. E. 1985. “New Products for Blood Treatment”.Artif. Organs 9, 207–208.

    Article  Google Scholar 

  • Wizemann, V., P. Rauer, R. Schmidt, F. Techert, G. Schutterle. 1981. “Efficiency of Hemodialysis, Hemofiltration, Hemodiafiltration”. InHemodiafiltration Proceedings 1,Symposion Giessen 1981, pp. 3–14.

  • Yuan, S. W. and A. B. Finkelstein. 1956. “Laminar Pipe Flow with Injection and Suction through a Porous Wall”.Trans. ASME 78, 719–724.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tyagi, V.P., Abbas, M. An exact analysis for a solute transport, due to simultaneous dialysis and ultrafiltration, in a hollow-fibre artificial kidney. Bltn Mathcal Biology 49, 697–717 (1987). https://doi.org/10.1007/BF02481768

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02481768

Keywords

Navigation