Skip to main content
Log in

Electrically stimulated Krebs-Henseleit buffer does not relax precontracted human bronchiin vitro

  • Mediators of Hypersensitivity Reactions
  • Published:
Agents and Actions Aims and scope Submit manuscript

Abstract

Electric field stimulation (EFS) causes a non-adrenergic relaxation of precontracted human airways. Only 10–20% of this response can be blocked with the nervous conductance blocker tetrodotoxin (TTX). Therefore, 80–90% of the non-adrenergic relaxation is not neurally mediated. The mechanism of this non-neural component is unclear. We examined whether EFS induces the generation of muscle relaxing substances in oxygenated Krebs-Henseleit buffer. Strips of central airways of 6 patients were precontracted with methacholine (10−5 M) and exposed to Krebs buffer that had previously been stimulated with EFS (50 V, 0.3 ms, 30 s, 1–50 Hz). Results were compared to those obtained with unstimulated buffer. The contractile state of the airways did not change significantly with either EFS-stimulated or unstimulated buffer. We conclude that in oxygenated Krebs buffer EFS does not cause generation of substances that change the contractile state of prestimulated human airways.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. C. de Jongste, H. Mons, I. L. Bonta and K. F. Kerrebijn,In vitro responses of airways from an asthmatic patient. Eur. J. Respir. Dis.71, 23–29 (1987).

    PubMed  Google Scholar 

  2. S. M. Taylor, P. D. Paré and R. R. Schellenberg,Cholinergic and non-adrenergic mechanisms in human and guinea pig airways. J. Appl. Physiol.: Respirat. Environ. Exercise Physiol.56, 958–965 (1984).

    Google Scholar 

  3. B. Greenberg, K. Rhoden and P. J. Barnes,Activated oxygen molecules generated by electrical stimulation affect vascular smooth muscle. J. Moll. Cell. Cardiol.18, 975–981 (1986).

    Google Scholar 

  4. J. C. de Jongste, R. van Strik, I. L. Bonta and K. F. Kerrebijn,Measurement of human airway smooth muscle function in vitro with the bronchiolar strip preparation. J. Pharmacol. Methods14, 111–118 (1985).

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jongejan, R.C., de Jongste, J.C., Raatgeep, R.C. et al. Electrically stimulated Krebs-Henseleit buffer does not relax precontracted human bronchiin vitro . Agents and Actions 26, 75–76 (1989). https://doi.org/10.1007/BF02126563

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02126563

Keywords

Navigation