Abstract
Mandibular repositioning appliances (tMRAs) designed with a titratable mechanism are effective to treat obstructive sleep apnea syndrome (OSAS) but are not widely used, although many studies have proven their value. The aim of the present study was to evaluate the efficacy of tMRAs in the treatment of OSAS on the criteria of the American Academy of Sleep Medicine (AASM; apnea/hypopnea index [AHI] < 5). Three hundred consecutive patients with a polysomnographic diagnosis of OSAS were referred for treatment with tMRAs between 2000 and 2003. Thirty-eight patients were excluded, and 262 concluded the titration protocol with tMRA that lasted 4 months. After titration, the patients were referred for a medical reassessment, and 83 patients (70 men) participated in the new polysomnographic exam with tMRA in place to access tMRA’s efficacy. The mean pre- and post-treatment AHI were 26 ± 17.7 and 4.8 ± 5.3 events per hour, respectively (p < 0.00005). Fifty-three (62.6%) of the 83 patients were treated successfully (AHI < 5). Twenty-three patients had severe OSAS, and 12 of them (52.1%) were treated successfully (AHI < 5). Forty patients had moderate OSAS, and 26 of them (65%) were treated successfully. Twenty patients had mild OSAS, and 15 (75%) were successfully treated. Even when applying more rigid criteria such as those of the AASM, the expressive success rate obtained with the treatment of different degrees of OSAS indicates that tMRAs are an additional valuable option even for cases of severe apnea in which the patient does not tolerate continuous positive airway pressure or cannot afford this treatment, a fact quite common in Brazil and other developing countries.
Similar content being viewed by others
References
Peppard PE, Young T, Palta M, Skatrud J (2000) Prospective study of the association between sleep-disordered breathing and hypertension. N Engl J Med 342(19):1378–1384
Hoffstein V, Rubinstein I, Mateka S, Slutsky AS (1988) Determinants of blood pressure in snorers. Lancet 29:992–994
Becker HF, Jerrentrup A, Ploch T et al (2003) Effect of nasal continuous positive airway treatment on blood pressure in patients with obstructive sleep apnea. Circulation 107:68–73
The report of an American Academy of Sleep Medicine Task Force (1999) Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. Sleep 22:667–689
Stepnowsky CJ, Marler MR, Ancoli-Israel S (2002) Determinants of nasal CPAP compliance. Sleep Med 3:239–247
Kribbs NB, Pack AI, Kline LR et al (1993) Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am Rev Respir Dis 147(4):887–895
Yaggi HK, Concato J, Kernan WN et al (2005) Obstructive sleep apnea as a risk factor for stroke and death. N Engl J Med 353(19):2034–2041
Mayer G, Meier-Ewert K (1995) Cephalometric predictors for orthopaedic mandibular advancement in obstructive sleep apnoea. Eur J Orthod 17:35–43
Ivanhoe JR, Attanasio R (2001) Sleep disorders and oral devices. Dent Clin North Am 45(4):733–758
De Almeida FR, Lowe AA, Otsuka R et al (2006) Long-term sequelae of oral appliance therapy in obstructive sleep apnea patients. Part 2: study model analysis. Am J Orthod Dentofac Orthop 129(2):205–213
Kato J, Isono S, Tanaka A et al (2000) Dose-dependent effects of mandibular advancement on pharyngeal mechanics and nocturnal oxygenation in patients with sleep-disordered breathing. Chest 117(4):1065–1072
Ferguson KA, Lowe AA (2005) Oral appliances for sleep-disordered breathing. In: Kryger MH, Roth T, Dement WC (eds) Principles and practice of sleep medicine, 4th edn. Elsevier Saunders, Philadelphia, USA, pp 1098–1108
Ng AT, Gotsopoulos H, Qian J, Cistulli PA (2003) Effect of oral appliance therapy on upper airway collapsibility in OSA. Am J Respir Crit Care Med 168:238–241
Engleman HM, McDonald JP, Graham D (2002) Randomized crossover trial of two treatments for sleep apnea/hypopnea syndrome: continuous positive airway pressure and mandibular repositioning splint. Am J Respir Crit Care Med 166:855–859
Gotsopoulos H, Chen C, Qian J, Cistulli PA (2002) Oral appliance therapy improves symptoms in OSAS: a randomized, controlled trial. Am J Respir Crit Care Med 166:743–748
Rechtschaffen A, Kales A (1968) A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects. NIH Publication 204. US Government printing office, Department of Health Education welfare, Washington
Machado MA, Carvalho LB, Juliano ML et al (2006) Clinical co-morbidities in obstructive sleep apnea syndrome treated with mandibular repositioning appliance. Respir Med 100(6):988–995 (Jun)
Lowe AA, Sjoholm TT, Ryan CF et al (2000) Treatment, airway and compliance effects of a titratable oral appliance. Sleep 23:172–178
Machado MAC, Carvalho LBC, Francisco S et al (2004) Quality of life of patients with obstructive sleep apnea syndrome treated with an intraoral mandibular repositioner. Arq Neuro-Psiquiatr 62:222–225
Neter J, Kutner MH, Nashtsheim CJ, Wasserman W (1996) Applied linear statistical models, 4th edn. McGraw-Hill, Boston, pp 1408
Barnes M, McEvoy RD, Banks S et al (2004) Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea. Am J Respir Crit Care Med 170:656–664
Ferguson KA, Ono T, Lowe AA (1996) A randomized crossover study of an oral appliance vs CPAP in the treatment to mild–moderate OSAS. Chest 109:1269–1275
Ferguson KA, Ono T, Lowe AA et al (1997) A short-term controlled trial of an adjustable oral appliance for the treatment of mild to moderate obstructive sleep apnea. Thorax 52:362–368
O’Sullivan RA, Hillman DR, Mateljan R et al (1995) Mandibular advancement splint: an appliance to treat snoring and obstructive sleep apnea. Am J Respir Crit Care Med 151:194–198
Clark GT, Blumenfeld I, Yoffe N et al (1996) A crossover study comparing the efficacy of CPAP with anterior mandibular positioning devices on patients with OSA. Chest 109:1477–1483
Randerath WJ, Heise M, Hinz R, Ruehle KH (2002) An individually adjustable oral appliance vs CPAP in mild-to-moderate OSAS. Chest 122:569–575
Engleman HM, Kingshott RN, Wraith PK et al (1999) Randomized placebo-controlled crossover trial of continuous positive airway pressure for mild sleep apnea hypopnea syndrome. Am J Respir Crit Care Med 159:461–467
Pancer J, Al-Faifi S, Al-Faifi M, Hoffstein V (1999) Evaluation of variable mandibular advancement appliance for treatment of snoring and sleep apnea. Chest 116(6):1511–1518
Walker-Engstrom ML, Tegelberg A, Wilhelmsson B, Ringqvist I (2002) 4-year follow-up of treatment with dental appliance or uvulopalatopharyngoplasty in patients with obstructive sleep apnea. Chest 121(3):739–746
Marklund M, Sahlin C, Stenlund H et al (2001) Mandibular advancement device in patients with OSAS: long term effects on apnea and sleep. Chest 120:162–169
Reeves-Hoche MK, Meck R, Zwillich CW (1994) Nasal CPAP: an objective evaluation of patient compliance. Am J Respir Crit Care Med 149(1):149–154
Fransson AM, Tegelberg A, Leissner L et al (2003) Effects of a mandibular protruding device on the sleep of patients with obstructive sleep apnea and snoring problems: a 2-year follow-up. Sleep Breath 7(3):131–141
Marklund M, Stenlund H, Franklin KA (2004) Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Chest 125(4):1270–1278
Acknowledgment
We would like to thank Mr. David George Elliff for the English translation.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Machado, M.A.C., Juliano, L., Taga, M. et al. Titratable mandibular repositioner appliances for obstructive sleep apnea syndrome: are they an option?. Sleep Breath 11, 225–231 (2007). https://doi.org/10.1007/s11325-007-0109-y
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11325-007-0109-y