Abstract
This study assessed physician performance in detecting the apical S3 gallop using a cardiology patient simulator. Six physicians (two cardiology fellows, two medicine residents, and two attending physicians) performed two sets of 24 cardiac examinations that included the presence or absence of an apical S3 gallop. All the examiners were able to significantly alter the prior odds of an apical S3 gallop’s being present, but the cardiology fellows had higher sensitivities. Sensitivity was lower for detecting soft S3 gallops, and specificity was lower when a diastolic murmur was also present. Physician performance in detecting apical S3 gallops is variable, but can be excellent.
References
Harlan WR, Oberman A, Grimm R, Rosati RA. Chronic congestive heart failure in coronary heart disease: clinical criteria. Ann Intern Med. 1977;86:133–8.
Mattleman SJ, Hakki A, Iskandrian AS, Segal BL, Kane SA. Reliability of bedside evaluation in determining left ventricular function: correlation with left ventricular ejection fraction determined by radionuclide ventriculography. J Am Coll Cardiol. 1983;1:417–20.
Gadsboll N, Hoilund-Carlsen PF, Nielsen GG, et al. Interobserver agreement and accuracy of bedside estimation of right and left ventricular ejection fraction in acute myocardial infarction. Am J Cardiol. 1989;63:1301–7.
Folland ED, Kriegel BJ, Henderson WG, Hammermeister KE, Sethi GK. Implications of third heart sounds in patients with valvular heart disease. N Engl J Med. 1992;327:458–62.
Goldman L, Caldera DL, Nussbaum SR, et al. Multifactorial index of cardiac risk in noncardiac surgical procedures. N Engl J Med. 1977;297:845–50.
Detsky AS, Abrams HB, McLaughlin JR, et al. Predicting cardiac complications in patients undergoing non-cardiac surgery. J Gen Intern Med. 1986;1:211–9.
Lee DC-S, Johnson RA, Bingham JB, et al. Heart failure in outpatients: a randomized trial of digoxin versus placebo. N Engl J Med. 1982;306:699–705.
Guyatt GH, Sullivan MJJ, Fallen EL, et al. A controlled trial of digoxin in congestive heart failure. Am J Cardiol. 1988;61:371–5.
Mulrow CD, Feussner JR, Velez R. Evaluation of digitalis efficacy: new light on an old leaf. Ann Intern Med. 1984;101:133–7.
Raftery EB, Holland WW. Examination of the heart: an investigation into variation. Am J Epidemiol. 1987;85:438–44.
Held P, Lindberg B, Swedberg K. Audibility of an artificial third heart sound in relation to its frequency, amplitude, delay from the second heart sound and the experience of the observer. Am J Cardiol. 1984;53:1169–72.
Sloan AW, Campbell FW. Henderson AS. Incidence of the physiological third heart sound. Br Med J. 1952;2:853–5.
Ishmail AA, Wing S, Ferguson J, Hutchinson TA, Magder S, Flegel KM. Interobserver agreement by auscultation in the presence of a third heart sound in patients with congestive heart failure. Chest. 1987;91:870–3.
Mangione S, Nieman LZ, Gracely E, Kaye D. The teaching and practice of cardiac auscultation during internal medicine and cardiology training. A nationwide survey. Ann Intern Med. 1993;119:47–54.
Gordon MS, Ewy GA, Felner JM, et al. Teaching bedside cardiologic examination skills using “Harvey,” the cardiology patient simulator. Med Clin North Am. 1980;64:305–13.
Gordon MS, Ewy GA, Felner JM, et al. A cardiology patient simulator for continuing education of family physicians. J Fam Pract. 1981;13:353–6.
Ewy GA, Felner JM, Juul D, et al. Test of a cardiology patient simulator with students in fourth-year electives. J Med Educ. 1987;62:738–43.
Oddone EZ, Waugh RA, Samsa GP, Corey R, Feussner JR. Teaching cardiovascular examination skills: results from a randomized controlled trial. Am J Med. 1993;95:389–96.
Sapira JD. The Art and Science of Bedside Diagnosis. Baltimore: Williams & Wilkins, 1990.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Westman, E.C., Matchar, D.B., Samsa, G.P. et al. Accuracy and reliability of apical S3 gallop detection. J Gen Intern Med 10, 455–457 (1995). https://doi.org/10.1007/BF02599919
Issue Date: