Skip to main content
Log in

Numerical model of deep venous thrombosis detection using venous occlusion strain gauge plethysmography

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Strain gauge plethysmography (SGP) is a non-invasive method used in the detection of deep venous thrombosis (DVT). The technique is based on the measurement of calf volume changes in response to venous occlusion by a thigh cuff, the volume changes reflecting the rates of arterial inflow and venous outflow. A numerical model of the blood circulation within the limb and the response of this to a SGP test has been derived, based on treating the different parts of the circulatory system in the leg as resistance and capacitance elements. The simulation results were compared with clinical studies and support the ability of SGP to detect non-occlusive clots of more than 50–60% of the lumen, as well detecting calf vein pressure appears to be a particularly important factor within the model. In addition, increases in venous tone due to post-operative venospasm were shown to be a potential source of false positive results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Anderson, F. A., Durgin, W. W., andBrownell Wheeler, H. (1986): ‘Interpretation of venous occlusion plethysmorgaphy using action-linear model’,Med. Biol. Eng. Comput.,24, pp. 379–385.

    Google Scholar 

  • Anderson, S. (1986): ‘Thermography and plethysmography in the diagnosis of deep vein thrombosis: a comparison with phlebography’,Acta Med. Scand.,219, pp. 359–366.

    Google Scholar 

  • Caro, C. G., Pedley, T. J., Schroter, R. C., andSeed, W. A. (1978): The mechanics of the circulation’ (Oxford University Press)

  • Cramer, M., Beach, K. W., andStrandness, D. E. (1983a):, ‘The detection of proximal deep venous thrombosis by strain gauge plethysmography through the use of an outflow/capacitance discriminant line’,Bruit,7, pp. 17–21

    Google Scholar 

  • Cramer, M., Langois, Y., Beach, K., Martin, D., andStrandness, D. E. (1983b): ‘Standardization of venous flow measurements by strain gauge plethysmography in normal subject’,Bruit,7, pp. 33–40.

    Google Scholar 

  • Cranley, J. J., Canos, A. J., andSull, W. J. (1976): ‘The diagnosis of deep ven thrombosis: fallability of clinical symptoms and signs’,Arch. Surg.,11, pp. 34–36.

    Google Scholar 

  • Croal, S., Birkmyre, J., McNally, M. A., Hamilton, C., andMüllan, R. A. B. (1993): ‘Strain gauge plethysmography for the detection of deep venous thrombosis’,J. Biomed. Eng.,15, pp. 135–139.

    Google Scholar 

  • Hayes, J. P., Druga, J., Needham, T. N., Vermilion, B. D., andEvans, W. E. (1986): ‘The contribution of the superficial venous system in the calculation of maximum venous outflow in the normal extremity’. Proc. IEEE 8th Ann. Conf. Eng. Med. Biol. Soc., pp. 27–29.

  • Hewlett, A. W., andVan Zwalumenburg, J. G. (1909): ‘The rate of blood flow in the arm’,Heart,1, pp. 87–97

    Google Scholar 

  • Laverick, M. D., McGivern, R. C., Brown, J. G., Birkmyre, J. S., Kernohan, W. G., Croal, S. A., McNally, M. A., andMollan, R. A. B. (1992): ‘A computerised system of screening for deep venous thrombosis’,Thromb. Res.,66, pp. 207–214

    Article  Google Scholar 

  • McLachan, M. S. F., Thomson, J. G., Taylor, D. W., Kelly, M. E., andSackett, D. L. (1979): ‘Observer variation in the interpretation of lower limb venograms’,Am. J. Roentgenology,132, pp. 227–230

    Google Scholar 

  • McNally, M. A., Mollan, R. A. B., andBuxton, M. J. (1993a): ‘Reducing the cost of post-operative deep venous thrombosis’,J. Manage. Med.,7, pp. 22–28

    Google Scholar 

  • McNally, M. A., Kernohan, W. G., Croal, S. A., andMollan, R. A. B. (1993a): ‘Deep venous thrombosis in orthopaedic patients: improving the specificity of diagnosis’,Clin. Orthop. Rel. Res.,295, pp. 275–280

    Google Scholar 

  • McNally, M. A., andMollan, R. A. B. (1993): ‘Total hip replacement, lower limb blood flow and venous thrombogenesis’,J. Bone Jt. Surg.,75-B, pp. 640–644

    Google Scholar 

  • Mellander, S., andBjornberg, J. (1992): ‘Regulation of vascular smooth muscle tone and capillary pressure’,NIPS,7, pp. 113–119

    Google Scholar 

  • Seagar, A. D., Gibbs, J. M., andDavis, F. M. (1984): ‘Interpretation of venous occlusion plethysmographic measurements using a simple model’,Med. Biol. Eng. Comput.,22, pp. 12–18

    Google Scholar 

  • Sinton, A. M., Seagar, A. D., andDavis, F. M. (1988): ‘Automated venous occlusion plethysmograph’,Med. Biol. Eng. Comput.,26, pp. 295–302.

    Google Scholar 

  • Ward, P. E., Bradley, F. B., Brown, J. G., Kernohan, W. G., McGivern, R. C., andMollan, R. A. B. (1989): ‘Impedance plethysmography’,Clin. Orthop.,248, pp. 195–199

    Google Scholar 

  • Woolson, S. T., andPottorf, G. (1991): ‘Venous ultrasonography in the detection of proximal vein thrombosis after total knee arthroplasty,Clin. Orthop.,273, pp. 131–000?

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to I. C. Turner.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Turner, I.C., McNally, M.A., O'Connell, B.M. et al. Numerical model of deep venous thrombosis detection using venous occlusion strain gauge plethysmography. Med. Biol. Eng. Comput. 38, 348–355 (2000). https://doi.org/10.1007/BF02347057

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02347057

Keywords

Navigation