Abstract
Patch-clamping is a powerful method for investigating the function and regulation of ionic channels. Currently, great efforts are being made to automate this method. As a step towards this goal, the feasibility of patch-clamping primary cells with a microscopic opening in a planar substrate was tested. Using standard microfabrication and ion beam technology, small-diameter openings (2 and 4 μm) were formed in polyimide films (thickness 6.5 μm). Single cells (sheep Purkinje heart cells, Chinese hamster ovary cells) in a suspension were positioned on top of the opening and sucked towards the opening to improve adhesion of the cell to the planar substrate, hence increasing the seal resistance. Voltage/current measurements yielded a median seal resistance of 1.3MΩ with 4 μm openings (n=24) and 26.0 MΩ with 2 μm openings (n=75), respectively. With 2 μm openings, successful loose-patch recordings of TTX-sensitive inward currents and action potentials in sheep Purkinje heart cells (n=18) were made. In rare cases, gigaseals (n=4) were also measured, and a whole-cell configuration (n=1) could be established. It was concluded that the simple planar patch approach is suitable for automated loosepatch recordings from cells in suspension but will hardly be suitable for highthroughput whole-cell patch-clamping with high-resistance seals.
Similar content being viewed by others
References
Bove, M., Grattarola, M., andVerreschi, G. (1997): ‘In vitro 2-D networks of neurons characterized by processing the signals recorded with a planar microtransducer array’,IEEE Trans. Biomed. Eng.,44, pp. 964–977
Bove, M., Martinoia, S., Verreschi, G., Giugliano, M., andGrattarola, M. (1998): ‘Analysis of the signals generated by networks of neurons coupled to planar arrays of microtransducers in simulated experiments’,Biosens. Bioelectron.,13, pp. 601–612
Braun, D., andFromherz, P. (1998): ‘Fluorescence interferometry of neuronal cell adhesion on microstructured silicon’,Phys. Rev. Lett.,81, pp. 5241–5244
Buitenweg, J. R., Rutten, W. L., Willems, W. P., andvan Nieuwkasteele, J. W. (1998): ‘Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy’,Med. Biol. Eng. Comput.,36, pp. 630–637
Buitenweg, J. R., Rutten, W. L., andMarani, E. (2000): ‘Finite element modeling of the neuron-electrode interface’,IEEE Eng. Med. Biol. Mag.,19, pp. 46–52
Buitenweg, J. R., Rutten, W. L., Marani, E., Polman, S. K., andUrsum, J. (2002): ‘Extracellular detection of active membrane currents in the neuron-electrode interface’,J. Neurosci. Methods,115, pp. 211–221
Corey, D. P., andStevens, C. F. (1983): ‘Science and technology of patch-recording electrodes’, inSakmann, B., andNeher, E. (Eds): ‘Single-channel recording’, (Plenum Press, New York, London, 1983), pp. 53–68
Dixon, A. K., Richardson, P. J., Pinnock, R. D., andLee, K. (2000): ‘Gene-expresssion analysis at the single-cell level’,TiPS,21, pp. 65–70
Fertig, N., Blick, R. H., andBehrends, J. C. (2002): ‘Whole cell patch clamp recording performed on a planar glass chip’,Biophys. J.,82, pp. 3056–3062
Fromherz, P. (1999): ‘Extracellular recording with transistors and the distribution of ionic conductances in a cell membrane’,Eur. Biophys. J.,28, pp. 254–258
Fromherz, P., andStett, A. (1995): ‘Silicon-neuron junction: capacitive stimulation of an individual neuron on a silicon chip’,Phys. Rev. Lett.,75, pp. 1670–1673
Glitsch, H. G., Krahn, T., andPusch, H. (1989): ‘The dependence of sodium pump current on internal Na concentration and membrane potential in cardioballs from sheep Purkinje fibres’,Pflügers Archiv.,414, pp. 52–58
González, J. E., Oades, K., Leychkis, Y., Harootunian, A., andPinnock, R. D. (1999): ‘Cell-based assays and instrumentation for screening ion-channel targets’,Drug Discov. Today,4, pp. 431–439
Guia, A., Wang, X., Xu, J., Sithiphong, K., Yang, Z., Cui, C., Wu, L., Han, E., andXu, J. (2002): ‘Micro-positioning enabled patch clamp recordings on a chip’. Biophysical Society Meeting, San Francisco, CA, USA, pp. Abstract 787-Pos
Hamil, O. P., Marty, A., Neher, E., Sakmann, B., andSigworth, F. J. (1981): ‘Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches’,Pflügers Archiv.,406, pp. 73–82
Johnston, P. A., andJohnston, P. A. (2002): ‘Cellular platforms for HTS: three case studies’,Drug Discov. Today,7, pp. 353–363
Maher, M. P., Pine, J., Wright, J., andTai, Y. C. (1999): ‘The neurochip: a new multielectrode device for stimulating and recording from cultured neurons’,J. Neurosci. Methods,87, pp. 45–56
Mathes, C., Osipchuk, Y., Savtchenko, A., Yang, I., andA., B. (2001): ‘Whole-cell recordings from planar patch clamp electrodes: a step towards high-throughput electrophysiology’. Society for Biomolecular Screening 7th Annual Conference (Baltimore MD, USA), Abstract p. 5039
Monyer, H., andLambolez, B. (1995): ‘Molecular biology and physiology at the single-cell level’,Curr. Opin. Neurobiol.,5, pp. 382–387
Neher, E. (1992): ‘Ion channels for communication between and within cells (Nobel Lecture)’,Neuron,8, pp. 605–612
Numann, R., andNegulescu, P. A. (2001): ‘High-throughput screening strategies for cardiac ion channels’,Trends Cardiovasc. Med.,11, pp. 54–59
Opsahl, L. R., andWebb, W. W. (1994): ‘Lipid-glass adhesion in giga-sealed patch-clamped membranes’,Biophys. J.,66, pp. 75–79
Owen, D., andSilverthorne, A. (2002): ‘Channelling drug discovery. Current trends in ion channel drug discovery research’,Drug Discov. World,3, pp. 48–61
Potter, S. M. (2001): ‘Distributed processing in cultured neuronal networks’,Prog. Brain Res.,130, pp. 49–62
Rutten, W. L., Smit, J. P., Frieswijk, T. A., Bielen, J. A., Brouwer, A. L., Buitenweg, J. R., andHeida, C. (1999): ‘Neuro-electronic interfacing with multielectrode arrays’,IEEE Eng. Med. Biol. Mag.,18, pp. 47–55
Sakmann, B., andNeher, E. (1983): ‘Geometric parameters of pipettes and membrane patches’, inSakmann, B., andNeher, E. (Eds): ‘Single-channel recording’ (Plenum Press, New York, London, 1983), pp. 37–51
Schmidt, C., Mayer, M., andVogel, H. (2000): ‘A chip-based biosensor for the functional analysis of single ion channels’,Angew. Chem. Int. Ed.,39, pp. 3137–3140
Sigworth, F. J., andKlemic, K. G. (2002): ‘Patch clamp on a chip’,Biophys. J.,82, pp. 2831–2832
Sorribas, H., Braun, D., Leder, L., Sonderegger, P., andTiefenauer, L. (2001): ‘Adhesion proteins for a tight neuronelectrode contact’,J. Neurosci. Methods,104, pp. 133–141
Stühmer, W., Roberts, W. M., andAlmers, W. (1983): ‘The loose patch clamp’, inSakmann, B., andNeher, E. (Eds): ‘Single-channel recording’ (Plenum Press, New York, London, 1983), pp. 123–132
Weis, R., Muller, B., andFromherz, P. (1996): ‘Neuron adhesion on a silicon chip probed by an array of field-effect transistors’,Phys. Rev. Lett.,76, pp. 327–330
Xu, J., Wang, X., Ensign, B., Li, M., Wu, L., andGuia, A. (2001): ‘Ion-channel assay technologies: quo vadis?’,Drug Discov. Today,6, pp. 1278–1287
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Stett, A., Bucher, V., Burkhardt, C. et al. Patch-clamping of primary cardiac cells with micro-openings in polyimide films. Med. Biol. Eng. Comput. 41, 233–240 (2003). https://doi.org/10.1007/BF02344895
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02344895