Skip to main content
Log in

Patch-clamping of primary cardiac cells with micro-openings in polyimide films

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Patch-clamping is a powerful method for investigating the function and regulation of ionic channels. Currently, great efforts are being made to automate this method. As a step towards this goal, the feasibility of patch-clamping primary cells with a microscopic opening in a planar substrate was tested. Using standard microfabrication and ion beam technology, small-diameter openings (2 and 4 μm) were formed in polyimide films (thickness 6.5 μm). Single cells (sheep Purkinje heart cells, Chinese hamster ovary cells) in a suspension were positioned on top of the opening and sucked towards the opening to improve adhesion of the cell to the planar substrate, hence increasing the seal resistance. Voltage/current measurements yielded a median seal resistance of 1.3MΩ with 4 μm openings (n=24) and 26.0 MΩ with 2 μm openings (n=75), respectively. With 2 μm openings, successful loose-patch recordings of TTX-sensitive inward currents and action potentials in sheep Purkinje heart cells (n=18) were made. In rare cases, gigaseals (n=4) were also measured, and a whole-cell configuration (n=1) could be established. It was concluded that the simple planar patch approach is suitable for automated loosepatch recordings from cells in suspension but will hardly be suitable for highthroughput whole-cell patch-clamping with high-resistance seals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bove, M., Grattarola, M., andVerreschi, G. (1997): ‘In vitro 2-D networks of neurons characterized by processing the signals recorded with a planar microtransducer array’,IEEE Trans. Biomed. Eng.,44, pp. 964–977

    Article  Google Scholar 

  • Bove, M., Martinoia, S., Verreschi, G., Giugliano, M., andGrattarola, M. (1998): ‘Analysis of the signals generated by networks of neurons coupled to planar arrays of microtransducers in simulated experiments’,Biosens. Bioelectron.,13, pp. 601–612

    Article  Google Scholar 

  • Braun, D., andFromherz, P. (1998): ‘Fluorescence interferometry of neuronal cell adhesion on microstructured silicon’,Phys. Rev. Lett.,81, pp. 5241–5244

    Google Scholar 

  • Buitenweg, J. R., Rutten, W. L., Willems, W. P., andvan Nieuwkasteele, J. W. (1998): ‘Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy’,Med. Biol. Eng. Comput.,36, pp. 630–637

    Google Scholar 

  • Buitenweg, J. R., Rutten, W. L., andMarani, E. (2000): ‘Finite element modeling of the neuron-electrode interface’,IEEE Eng. Med. Biol. Mag.,19, pp. 46–52

    Google Scholar 

  • Buitenweg, J. R., Rutten, W. L., Marani, E., Polman, S. K., andUrsum, J. (2002): ‘Extracellular detection of active membrane currents in the neuron-electrode interface’,J. Neurosci. Methods,115, pp. 211–221

    Article  Google Scholar 

  • Corey, D. P., andStevens, C. F. (1983): ‘Science and technology of patch-recording electrodes’, inSakmann, B., andNeher, E. (Eds): ‘Single-channel recording’, (Plenum Press, New York, London, 1983), pp. 53–68

    Google Scholar 

  • Dixon, A. K., Richardson, P. J., Pinnock, R. D., andLee, K. (2000): ‘Gene-expresssion analysis at the single-cell level’,TiPS,21, pp. 65–70

    Google Scholar 

  • Fertig, N., Blick, R. H., andBehrends, J. C. (2002): ‘Whole cell patch clamp recording performed on a planar glass chip’,Biophys. J.,82, pp. 3056–3062

    Google Scholar 

  • Fromherz, P. (1999): ‘Extracellular recording with transistors and the distribution of ionic conductances in a cell membrane’,Eur. Biophys. J.,28, pp. 254–258

    Article  Google Scholar 

  • Fromherz, P., andStett, A. (1995): ‘Silicon-neuron junction: capacitive stimulation of an individual neuron on a silicon chip’,Phys. Rev. Lett.,75, pp. 1670–1673

    Article  Google Scholar 

  • Glitsch, H. G., Krahn, T., andPusch, H. (1989): ‘The dependence of sodium pump current on internal Na concentration and membrane potential in cardioballs from sheep Purkinje fibres’,Pflügers Archiv.,414, pp. 52–58

    Google Scholar 

  • González, J. E., Oades, K., Leychkis, Y., Harootunian, A., andPinnock, R. D. (1999): ‘Cell-based assays and instrumentation for screening ion-channel targets’,Drug Discov. Today,4, pp. 431–439

    Article  Google Scholar 

  • Guia, A., Wang, X., Xu, J., Sithiphong, K., Yang, Z., Cui, C., Wu, L., Han, E., andXu, J. (2002): ‘Micro-positioning enabled patch clamp recordings on a chip’. Biophysical Society Meeting, San Francisco, CA, USA, pp. Abstract 787-Pos

  • Hamil, O. P., Marty, A., Neher, E., Sakmann, B., andSigworth, F. J. (1981): ‘Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches’,Pflügers Archiv.,406, pp. 73–82

    Google Scholar 

  • Johnston, P. A., andJohnston, P. A. (2002): ‘Cellular platforms for HTS: three case studies’,Drug Discov. Today,7, pp. 353–363

    Google Scholar 

  • Maher, M. P., Pine, J., Wright, J., andTai, Y. C. (1999): ‘The neurochip: a new multielectrode device for stimulating and recording from cultured neurons’,J. Neurosci. Methods,87, pp. 45–56

    Article  Google Scholar 

  • Mathes, C., Osipchuk, Y., Savtchenko, A., Yang, I., andA., B. (2001): ‘Whole-cell recordings from planar patch clamp electrodes: a step towards high-throughput electrophysiology’. Society for Biomolecular Screening 7th Annual Conference (Baltimore MD, USA), Abstract p. 5039

  • Monyer, H., andLambolez, B. (1995): ‘Molecular biology and physiology at the single-cell level’,Curr. Opin. Neurobiol.,5, pp. 382–387

    Article  Google Scholar 

  • Neher, E. (1992): ‘Ion channels for communication between and within cells (Nobel Lecture)’,Neuron,8, pp. 605–612

    Article  Google Scholar 

  • Numann, R., andNegulescu, P. A. (2001): ‘High-throughput screening strategies for cardiac ion channels’,Trends Cardiovasc. Med.,11, pp. 54–59

    Article  Google Scholar 

  • Opsahl, L. R., andWebb, W. W. (1994): ‘Lipid-glass adhesion in giga-sealed patch-clamped membranes’,Biophys. J.,66, pp. 75–79

    Google Scholar 

  • Owen, D., andSilverthorne, A. (2002): ‘Channelling drug discovery. Current trends in ion channel drug discovery research’,Drug Discov. World,3, pp. 48–61

    Google Scholar 

  • Potter, S. M. (2001): ‘Distributed processing in cultured neuronal networks’,Prog. Brain Res.,130, pp. 49–62

    Google Scholar 

  • Rutten, W. L., Smit, J. P., Frieswijk, T. A., Bielen, J. A., Brouwer, A. L., Buitenweg, J. R., andHeida, C. (1999): ‘Neuro-electronic interfacing with multielectrode arrays’,IEEE Eng. Med. Biol. Mag.,18, pp. 47–55

    Article  Google Scholar 

  • Sakmann, B., andNeher, E. (1983): ‘Geometric parameters of pipettes and membrane patches’, inSakmann, B., andNeher, E. (Eds): ‘Single-channel recording’ (Plenum Press, New York, London, 1983), pp. 37–51

    Google Scholar 

  • Schmidt, C., Mayer, M., andVogel, H. (2000): ‘A chip-based biosensor for the functional analysis of single ion channels’,Angew. Chem. Int. Ed.,39, pp. 3137–3140

    Google Scholar 

  • Sigworth, F. J., andKlemic, K. G. (2002): ‘Patch clamp on a chip’,Biophys. J.,82, pp. 2831–2832

    Google Scholar 

  • Sorribas, H., Braun, D., Leder, L., Sonderegger, P., andTiefenauer, L. (2001): ‘Adhesion proteins for a tight neuronelectrode contact’,J. Neurosci. Methods,104, pp. 133–141

    Article  Google Scholar 

  • Stühmer, W., Roberts, W. M., andAlmers, W. (1983): ‘The loose patch clamp’, inSakmann, B., andNeher, E. (Eds): ‘Single-channel recording’ (Plenum Press, New York, London, 1983), pp. 123–132

    Google Scholar 

  • Weis, R., Muller, B., andFromherz, P. (1996): ‘Neuron adhesion on a silicon chip probed by an array of field-effect transistors’,Phys. Rev. Lett.,76, pp. 327–330

    Article  Google Scholar 

  • Xu, J., Wang, X., Ensign, B., Li, M., Wu, L., andGuia, A. (2001): ‘Ion-channel assay technologies: quo vadis?’,Drug Discov. Today,6, pp. 1278–1287

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Stett.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stett, A., Bucher, V., Burkhardt, C. et al. Patch-clamping of primary cardiac cells with micro-openings in polyimide films. Med. Biol. Eng. Comput. 41, 233–240 (2003). https://doi.org/10.1007/BF02344895

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02344895

Keywords

Navigation